Atlantic L-310

Atlantic Water Gardens Tidal Wave L-310 Pump User Manual

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Atlantic Water Gardens Tidal Wave L-310 Pump. The Tidal Wave L-310 is a low-head, high-volume axial flow pump designed for water garden and pond applications, offering a capacity of 13500 GPH. Please read all instructions carefully before installation and use to ensure proper function and longevity of the product.

2. Important Safety Instructions

WARNING: To avoid serious injury, always disconnect power to the pump before performing any maintenance or installation procedures.

3. Package Contents

Verify that all components are present and undamaged upon opening the package:

Atlantic Water Gardens Tidal Wave L-310 Pump

Image 1: Atlantic Water Gardens Tidal Wave L-310 Pump. This image shows the main pump unit, typically black or dark gray, with a robust housing and a power cord extending from it. The pump is designed for submersible use in water features.

4. Installation and Setup

4.1. Placement

Place the pump on a stable, level surface within your pond or water feature. Ensure it is fully submerged and positioned to draw water effectively without pulling in excessive debris from the bottom. Avoid placing the pump directly in heavy sludge or loose gravel.

4.2. Plumbing Connection

Connect the appropriate plumbing (e.g., flexible tubing or PVC pipe) to the pump's discharge outlet. Ensure all connections are secure and watertight to prevent leaks and maintain optimal flow. Refer to your specific plumbing requirements for proper sizing and sealing.

4.3. Electrical Connection

Route the power cord to a GFCI-protected outdoor electrical outlet. Ensure the cord is protected from damage and is not pinched or strained. Do not use extension cords unless absolutely necessary and ensure they are rated for outdoor use and properly grounded.

5. Operation

Once the pump is properly installed and submerged, plug the power cord into the GFCI-protected outlet. The pump should start immediately, circulating water. Monitor the initial operation to ensure proper flow and check for any unusual noises or vibrations. The Tidal Wave L-310 is designed for continuous operation.

6. Maintenance

6.1. Regular Cleaning

Periodically inspect the pump intake for debris accumulation. Disconnect power before removing the pump from the water. Clean the pump housing and impeller area to remove any leaves, algae, or other obstructions that may reduce flow or strain the motor. Use a soft brush and clean water.

6.2. Winterization

In regions with freezing temperatures, remove the pump from the pond before the first hard freeze. Clean the pump thoroughly and store it in a frost-free location, submerged in a bucket of water to keep seals lubricated, or follow manufacturer recommendations for dry storage.

7. Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power; GFCI tripped; Impeller jammedCheck power connection; Reset GFCI; Disconnect power and clear impeller
Reduced water flowClogged intake/impeller; Kinked hose; Low water levelDisconnect power and clean pump; Straighten hose; Add water to pond
Pump making unusual noiseDebris in impeller; Pump running dry; Worn bearingsDisconnect power and clear debris; Ensure full submersion; Contact support if noise persists
GFCI trips repeatedlyFaulty wiring; Water in electrical connections; Damaged pump motorInspect wiring; Ensure dry connections; Discontinue use and contact support

8. Specifications

FeatureDetail
ModelL-310
Capacity13500 GPH
Maximum Lifting Height28 Feet
Voltage115 Volts
MaterialCast Iron, Stainless Steel
Product Dimensions (L x W x H)19.25" x 9" x 19.25"
Item Weight95 Pounds
Power SourceCorded Electric
UPC727429003060

9. Warranty and Support

9.1. Manufacturer's Warranty

The Atlantic Water Gardens Tidal Wave L-310 Pump is covered by a 2-year Manufacturer's Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

9.2. Customer Support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Atlantic Water Gardens customer support. Refer to the official Atlantic Water Gardens website or product packaging for current contact information.

Related Documents - L-310

Preview Atlantic TidalWave L-Series Submersible Pump Manual - L-305, L-310
Official product manual for the Atlantic TidalWave L-Series submersible pumps (models L-305 and L-310). Includes installation, operation, maintenance, troubleshooting, and warranty information.
Preview Atlantic TidalWave PAF Series Submersible Pump Manual - Installation, Operation, and Maintenance Guide
Detailed product manual for Atlantic TidalWave PAF-Series submersible pumps (PAF-20SV, PAF-25SV, PAF-40SV, PAF-75SV). Covers installation, safe operation, maintenance, troubleshooting, and warranty information.
Preview Atlantic TidalWave² Hybrid Pump Series Operating Manual
Operating manual for Atlantic TidalWave² Hybrid Pump Series (TW1200, TW1900, TW2400, TW3700, TW4800, TW6000). Covers specifications, safety, operation, maintenance, winterizing, warranty, cleaning, and troubleshooting.
Preview Atlantic TidalWave TT-Series Pump Product Manual
Comprehensive product manual for Atlantic TidalWave TT-Series pumps, covering installation, operation, maintenance, troubleshooting, and warranty information. Includes flow charts and safety guidelines.
Preview Atlantic Spillway Scupper Operating Manual and Installation Guide
Comprehensive operating manual for Atlantic Stainless Steel and Copper Finished Spillway Scuppers (models SS12, SS24, SS36, CS12, CS24, CS36). Includes detailed installation requirements, plumbing instructions, maintenance tips, winterization guide, and warranty information for these pond-free and fountain water features.
Preview Atlantic TidalWave Variable Speed Controller (VSC) TWVSC-73933 Product Manual
This product manual for the Atlantic TidalWave Variable Speed Controller (VSC) TWVSC-73933 details its features, installation, operation via the Atlantic Control app, safety precautions, maintenance, and troubleshooting. It enables Bluetooth® control for Atlantic TT-Series pumps.