1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Atlantic Water Gardens Tidal Wave L-310 Pump. The Tidal Wave L-310 is a low-head, high-volume axial flow pump designed for water garden and pond applications, offering a capacity of 13500 GPH. Please read all instructions carefully before installation and use to ensure proper function and longevity of the product.
2. Important Safety Instructions
WARNING: To avoid serious injury, always disconnect power to the pump before performing any maintenance or installation procedures.
- Ensure the pump is connected to a Ground Fault Circuit Interrupter (GFCI) protected outlet.
- Do not operate the pump if the power cord is damaged. Contact a qualified electrician for repair or replacement.
- Never run the pump dry. Ensure it is fully submerged in water during operation to prevent overheating and damage.
- Do not lift or carry the pump by its power cord. Use the designated handle or body of the pump.
- Keep children and pets away from the pump and water feature during operation.
- This pump is designed for water garden use only. Do not use with flammable liquids or in swimming pools.
3. Package Contents
Verify that all components are present and undamaged upon opening the package:
- Atlantic Water Gardens Tidal Wave L-310 Pump Unit
- Power Cord
- Instruction Manual

Image 1: Atlantic Water Gardens Tidal Wave L-310 Pump. This image shows the main pump unit, typically black or dark gray, with a robust housing and a power cord extending from it. The pump is designed for submersible use in water features.
4. Installation and Setup
4.1. Placement
Place the pump on a stable, level surface within your pond or water feature. Ensure it is fully submerged and positioned to draw water effectively without pulling in excessive debris from the bottom. Avoid placing the pump directly in heavy sludge or loose gravel.
4.2. Plumbing Connection
Connect the appropriate plumbing (e.g., flexible tubing or PVC pipe) to the pump's discharge outlet. Ensure all connections are secure and watertight to prevent leaks and maintain optimal flow. Refer to your specific plumbing requirements for proper sizing and sealing.
4.3. Electrical Connection
Route the power cord to a GFCI-protected outdoor electrical outlet. Ensure the cord is protected from damage and is not pinched or strained. Do not use extension cords unless absolutely necessary and ensure they are rated for outdoor use and properly grounded.
5. Operation
Once the pump is properly installed and submerged, plug the power cord into the GFCI-protected outlet. The pump should start immediately, circulating water. Monitor the initial operation to ensure proper flow and check for any unusual noises or vibrations. The Tidal Wave L-310 is designed for continuous operation.
6. Maintenance
6.1. Regular Cleaning
Periodically inspect the pump intake for debris accumulation. Disconnect power before removing the pump from the water. Clean the pump housing and impeller area to remove any leaves, algae, or other obstructions that may reduce flow or strain the motor. Use a soft brush and clean water.
6.2. Winterization
In regions with freezing temperatures, remove the pump from the pond before the first hard freeze. Clean the pump thoroughly and store it in a frost-free location, submerged in a bucket of water to keep seals lubricated, or follow manufacturer recommendations for dry storage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; GFCI tripped; Impeller jammed | Check power connection; Reset GFCI; Disconnect power and clear impeller |
| Reduced water flow | Clogged intake/impeller; Kinked hose; Low water level | Disconnect power and clean pump; Straighten hose; Add water to pond |
| Pump making unusual noise | Debris in impeller; Pump running dry; Worn bearings | Disconnect power and clear debris; Ensure full submersion; Contact support if noise persists |
| GFCI trips repeatedly | Faulty wiring; Water in electrical connections; Damaged pump motor | Inspect wiring; Ensure dry connections; Discontinue use and contact support |
8. Specifications
| Feature | Detail |
|---|---|
| Model | L-310 |
| Capacity | 13500 GPH |
| Maximum Lifting Height | 28 Feet |
| Voltage | 115 Volts |
| Material | Cast Iron, Stainless Steel |
| Product Dimensions (L x W x H) | 19.25" x 9" x 19.25" |
| Item Weight | 95 Pounds |
| Power Source | Corded Electric |
| UPC | 727429003060 |
9. Warranty and Support
9.1. Manufacturer's Warranty
The Atlantic Water Gardens Tidal Wave L-310 Pump is covered by a 2-year Manufacturer's Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
9.2. Customer Support
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Atlantic Water Gardens customer support. Refer to the official Atlantic Water Gardens website or product packaging for current contact information.