Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your KOHLER Brenham Wall Mount Lavatory, model K-1997-4-0. Please read this guide thoroughly before beginning installation or use to ensure proper function and longevity of your product. This wall-hung lavatory is crafted from vitreous china, offering both durability and a refined aesthetic suitable for various bathroom environments.
Safety Information
Always observe basic safety precautions when installing or servicing plumbing fixtures. Failure to follow these instructions could result in property damage, personal injury, or death.
- Turn off the main water supply before beginning any installation or repair work.
- Wear appropriate personal protective equipment, such as safety glasses and gloves.
- If you are unsure about any part of the installation process, consult a qualified plumber.
- Ensure all connections are secure and leak-free before restoring water supply.
- Do not overtighten connections, as this may cause damage to the fixture or plumbing.
Package Contents
Verify that all components are present before beginning installation. If any parts are missing or damaged, do not proceed with installation and contact KOHLER customer service.
- KOHLER Brenham Wall Mount Lavatory Unit
- Instruction Guide (this document)
- Mounting Hardware (may vary by package)
Setup and Installation
This section outlines the general steps for installing your wall-mount lavatory. Specific details may vary based on your plumbing configuration and local building codes. Always consult local plumbing codes before installation.
1. Pre-Installation Checks
- Ensure the wall structure is adequate to support the weight of the lavatory when filled with water. Reinforcement may be necessary.
- Verify that water supply lines and drain rough-ins are correctly positioned according to the lavatory's dimensions.
- Gather all necessary tools, including a level, tape measure, drill, wrenches, and sealant.
2. Mounting the Lavatory
- Mark the desired height and mounting points on the wall using the lavatory's template or measurements. Ensure the marks are level.
- Drill pilot holes at the marked locations.
- Secure the mounting brackets or bolts into the wall studs or appropriate anchors.
- Carefully lift the lavatory and align it with the mounting hardware. Secure the lavatory to the wall, ensuring it is level and stable.

Image: The KOHLER Brenham Wall Mount Lavatory, model K-1997-4-0, shown in white. This image illustrates the overall design and wall-mount configuration of the lavatory unit.
3. Connecting Plumbing
- Install the faucet and drain assembly onto the lavatory according to their respective manufacturer's instructions.
- Connect the hot and cold water supply lines to the faucet inlets. Hand-tighten, then use a wrench for a final quarter-turn.
- Connect the drain tailpiece to the P-trap and then to the wall drain. Ensure all slip nuts are tightened securely.
- Apply a bead of silicone sealant around the perimeter of the lavatory where it meets the wall, if desired, for a finished look and moisture seal.
- Turn on the main water supply slowly and check for leaks at all connections. Tighten any leaking connections as needed.
Operating
The KOHLER Brenham Wall Mount Lavatory operates like any standard sink. Turn the faucet handles to control water flow and temperature. Ensure the drain stopper is properly seated to retain water in the basin when desired. After use, ensure the water is turned off completely to prevent waste and potential overflow.
Maintenance
Proper care and maintenance will help preserve the finish and functionality of your lavatory.
Cleaning Instructions
- Clean the vitreous china surface regularly with a soft, dry cloth.
- For deeper cleaning, use a mild, non-abrasive cleaner specifically designed for bathroom fixtures.
- Avoid harsh chemicals, abrasive scrubbers, or acidic cleaners, as these can damage the finish and void the warranty.
- Rinse the lavatory thoroughly with clean water after cleaning and wipe dry to prevent water spots.
Troubleshooting
This section addresses common issues you might encounter with your lavatory. For problems not listed here, contact KOHLER customer service.
| Problem | Possible Cause | Solution |
|---|---|---|
| Leaks around connections | Loose connections, worn washers/gaskets | Tighten connections. Replace worn washers or gaskets. Ensure plumber's tape or sealant was used where appropriate. |
| Slow drainage | Clogged drain, P-trap obstruction | Remove and clean the drain stopper. Clear any debris from the P-trap. Use a plumbing snake if necessary. |
| Water spots or stains | Hard water deposits, improper cleaning | Wipe the lavatory dry after each use. Use a mild descaling agent for hard water spots, following product instructions. |
Specifications
Refer to the table below for key specifications of the KOHLER Brenham Wall Mount Lavatory K-1997-4-0.
| Feature | Detail |
|---|---|
| Brand | Kohler |
| Model Number | K-1997-4-0 |
| Color | White |
| Material | Vitreous china |
| Product Dimensions (D x W x H) | 25.82" x 9.63" x 22.88" |
| Installation Type | Wall-Mount |
| Finish Type | Brushed |
| Shape | Rectangular |
| Drain Type | Grid |
| Item Weight | 40 Pounds |
| Hole Count | 1 |
| UPC | 650531920195 |
Warranty
Your KOHLER Brenham Wall Mount Lavatory is covered by a one-year limited warranty. This warranty covers defects in material and workmanship under normal use and service. Please refer to the warranty card included with your product for full terms, conditions, and exclusions. Keep your proof of purchase for warranty claims.
Support
For technical assistance, replacement parts, or warranty claims, please contact KOHLER customer service. You can find contact information and additional resources by visiting the official KOHLER website: www.kohler.com. When contacting support, please have your model number (K-1997-4-0) and date of purchase readily available.