Rohl A4910
Rohl A4910 Thermostatic Shower Valve with Volume Control
User Manual
Introduction
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Rohl A4910 Thermostatic Shower Valve with Volume Control. Please read this manual thoroughly before installation and use to ensure proper function and longevity of your product.
Safety Information
Always turn off the main water supply before beginning any plumbing work. Ensure all connections are secure to prevent leaks. If you are unsure about any installation steps, consult a qualified plumber. Wear appropriate personal protective equipment, such as safety glasses and gloves, during installation.
Setup and Installation
The Rohl A4910 is a concealed thermostatic valve designed for shower systems. Proper installation is crucial for optimal performance.
- The valve features 1/2-turn service stops with screens for easy maintenance and flow control.
- It includes a bottom outlet specifically for a tub spout.
- A standard 3/4" nipple is required for plumbing from the bottom outlet (not supplied).
- If PEX piping is utilized, it is recommended to oversize the supply line to 1" to maintain optimal flow.
- The valve comes complete with a mud guard for protection during installation.
- To complete the installation, you must order one of the following trim sets: A4909, A2909, A4709, A4809, or A4009.

Figure 1: Rohl A4910 Thermostatic Shower Valve in packaging. This image displays the Rohl A4910 Thermostatic Shower Valve, still within its protective white foam packaging. The central brass thermostatic cartridge and the lower brass volume control cartridge are clearly visible. To the left and right of the thermostatic cartridge, two chrome-finished service stops are present. The valve body is metallic, and a portion of a white instruction or certification document is visible at the bottom.
Operating Instructions
The Rohl A4910 valve provides separate controls for water volume and temperature, allowing for precise adjustment of your shower experience.
- Temperature Control: Rotate the temperature handle (typically the upper control) to adjust the water temperature. Turn towards the 'Hot' indicator for warmer water and towards the 'Cold' indicator for cooler water. The thermostatic element maintains a consistent temperature regardless of pressure fluctuations in the water supply.
- Volume Control: Rotate the volume control handle (typically the lower control) to adjust the water flow rate. Turn clockwise to decrease flow and counter-clockwise to increase flow. This allows you to conserve water or achieve maximum flow as desired.
The valve has a flow rate of 16 GPM (gallons per minute) at 45 PSI (pounds per square inch), ensuring ample water delivery.
Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your Rohl A4910 valve.
- Cleaning: Clean the visible parts of the valve trim with a soft cloth and mild, non-abrasive cleaner. Avoid harsh chemicals or abrasive materials that can damage the finish.
- Service Stops: The 1/2-turn service stops can be used to isolate the valve for maintenance without shutting off the main water supply to the entire house. These stops also contain screens that should be periodically checked and cleaned if water flow is reduced.
- Thermostatic Cartridge: If you experience inconsistent water temperature, the thermostatic cartridge may need cleaning or replacement. This typically requires professional assistance.
Troubleshooting
Refer to the following table for common issues and their potential solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Low water flow | Clogged service stop screens; Debris in valve; Insufficient supply line size (for PEX) | Check and clean service stop screens; Flush the valve; Ensure 1" PEX supply lines are used. |
| Inconsistent water temperature | Thermostatic cartridge issue; Imbalance in hot/cold water pressure | Clean or replace thermostatic cartridge (professional recommended); Check household water pressure. |
| Water leaks from valve | Loose connections; Damaged O-rings or seals | Tighten connections; Inspect and replace O-rings/seals. |
If the problem persists after attempting these solutions, please contact Rohl customer support or a qualified plumber.
Specifications
| Attribute | Detail |
|---|---|
| Model Number | A4910 |
| Material | Metal |
| Item Weight | 6.75 pounds |
| Product Dimensions | 3.94 x 7.5 x 6.19 inches |
| Inlet Connection Type | Cross Linked Polyethylene (PEX) |
| Outlet Connection Type | PEX |
| Flow Rate | 16 GPM at 45 PSI |
| Inlets | 3/4" |
| Outlets | 2 x 3/4" |
| Included Components | Thermostatic Rough-In Valve |
| Color | Brass |
| UPC | 824438058088 |
Warranty
The Rohl A4910 Thermostatic Shower Valve is covered by a Limited Lifetime Warranty for defects. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the official Rohl warranty documentation or contact Rohl customer service.
Support
For further assistance, technical support, or to inquire about replacement parts, please visit the official Rohl website or contact their customer service department. When contacting support, please have your product model number (A4910) and purchase information readily available.
Related Documents - A4910
![]() |
ROHL 3/4" Thermostatic Trim Installation Manual Comprehensive installation guide for the ROHL 3/4" Thermostatic Trim, detailing parts, tools, and step-by-step assembly. Includes contact and warranty information. |
![]() |
ROHL R1040R & R1062BO Installation Guide, Care, and Warranty Comprehensive installation instructions, care and maintenance guidelines, and warranty details for ROHL R1040R rough-in valves and R1062BO three-way diverter valves. Includes product specifications, parts lists, and finish care advice. |
![]() |
Rohl Volume Control or Diverter Trim Installation Manual Detailed installation instructions for Rohl Volume Control or Diverter Trim (Model INS12615A, Rev. 10/22). Includes parts list, helpful tools, and contact information for Rohl, Riobel, Perrin & Rowe, Shaws, and Victoria + Albert brands in the US and Canada. |
![]() |
ROHL 1/2" Therm & Pressure Balance Trim Installation Manual Detailed installation instructions for the ROHL 1/2" Therm & Pressure Balance Trim (Model 23-44-45-47) from House of Rohl. Includes parts list, tools required, and step-by-step guidance for safe and proper installation. |
![]() |
ROHL Edwardian™ Thermostatic & Pressure Balance Valve Trim - Installation, Specifications, and Product Catalog Comprehensive guide for ROHL plumbing fixtures, including the Edwardian™ U.TEW44W1 valve trim, 2-Way Type T/P Coaxial Valve Rough, handshowers, showerheads, and accessories. Features installation instructions, parts lists, product specifications, finishes, warranty information, and customer support. |
![]() |
Rohl 1/2" Therm & Pressure Balance Trim Installation Manual Installation instructions for Rohl 1/2" Therm & Pressure Balance Trim sets (23-44-45-47). Includes parts list, tool requirements, and step-by-step assembly guide. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.