Fireangel CO-9B

Fireangel CO-9B Carbon Monoxide Alarm User Manual

Model: CO-9B

1. Introduction

The Fireangel CO-9B Carbon Monoxide Alarm is designed to detect dangerous levels of carbon monoxide (CO) gas in your home or other living spaces. Carbon monoxide is a colorless, odorless, and tasteless gas that can be fatal. This alarm provides an early warning of CO presence, helping to protect you and your family.

This device features an advanced electrochemical sensor and is Kitemark certified to EN 50291-1: 2010+A1:2012 and EN 50291-2:2010, ensuring reliable performance. It is suitable for both wall-mounted and portable use, including in caravans, motor caravans, and boats.

2. Product Features

3. Setup and Installation

Proper placement of your CO alarm is crucial for effective detection. The Fireangel CO-9B can be wall-mounted or placed freestanding.

3.1 Recommended Placement

Fireangel CO-9B Carbon Monoxide Alarm placed on a hearth near a fireplace

Image 3.1: The Fireangel CO-9B alarm positioned on a hearth, demonstrating a typical placement near a potential CO source. The compact design allows for discreet integration into living spaces.

3.2 Battery Installation

The CO-9B requires 2 AA Alkaline batteries (not included). Ensure batteries are inserted with correct polarity as indicated inside the battery compartment. The unit will not function without batteries.

Front view of Fireangel CO-9B Carbon Monoxide Alarm showing test button and indicator lights

Image 3.2: Front view of the Fireangel CO-9B Carbon Monoxide Alarm. This image highlights the central test button and the indicator lights for power and alarm status, which are essential for operation and testing.

3.3 Wall Mounting (Optional)

If wall mounting, use the provided screws and wall plugs. Mark the desired location, drill pilot holes, insert wall plugs, and secure the mounting bracket (if applicable) or the alarm directly. Ensure the alarm is firmly attached.

Side profile view of Fireangel CO-9B Carbon Monoxide Alarm

Image 3.3: Side profile view of the Fireangel CO-9B Carbon Monoxide Alarm. This perspective illustrates the slim design and potential mounting points on the rear or side, aiding in understanding its physical dimensions for installation.

4. Operating Instructions

4.1 Initial Power-Up

Once batteries are installed, the alarm will perform a self-test. A green LED will typically illuminate or flash, indicating the unit is powered and functioning correctly. Refer to the specific LED patterns in the troubleshooting section for detailed status indications.

4.2 Testing the Alarm

It is recommended to test your CO alarm weekly. Press and hold the 'TEST' button (usually a large central button on the front of the unit). The alarm will sound a loud siren (85dB) and the alarm indicator light will flash. Release the button to stop the test. If the alarm does not sound or the indicator light does not flash, refer to the troubleshooting section.

4.3 Alarm Indication

If carbon monoxide is detected, the alarm will sound a loud, intermittent siren and the red alarm indicator light will flash. This indicates a dangerous level of CO. Immediately follow the 'What to do if the alarm sounds' procedure outlined in the troubleshooting section.

5. Maintenance

5.1 Battery Replacement

The alarm will emit a regular chirp or flash a specific indicator when the batteries are low. Replace both AA Alkaline batteries immediately. Do not mix old and new batteries or different battery types.

5.2 Cleaning

Clean the alarm regularly by gently wiping the exterior with a damp cloth. Do not use cleaning solvents or polishes, as these can damage the sensor. Do not paint the alarm.

5.3 End of Life Indication

The Fireangel CO-9B has a 7-year operational life. After this period, the alarm will indicate its end-of-life through a specific chirp pattern or indicator light. Replace the unit immediately upon receiving this signal, as the sensor's accuracy may degrade over time.

6. Troubleshooting

6.1 Common Issues

ProblemPossible CauseSolution
Alarm chirps regularly (e.g., every 30-60 seconds)Low battery warning.Replace both AA Alkaline batteries immediately.
Alarm sounds continuously or intermittently without CO presentEnd-of-life warning or fault.If the unit is older than 7 years, replace it. If newer, contact Fireangel support.
Alarm does not sound during testNo batteries, dead batteries, or unit fault.Ensure batteries are correctly installed and fresh. If problem persists, replace unit.

6.2 What to do if the alarm sounds

  1. Evacuate Immediately: Move everyone, including pets, to fresh air outdoors.
  2. Do Not Re-enter: Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
  3. Ventilate: Open all doors and windows to ventilate the area.
  4. Identify Source: If possible and safe to do so, turn off all fuel-burning appliances.
  5. Call for Help: Contact your gas or fuel supplier on their emergency number. If unavailable, call the emergency services.
  6. Professional Check: Do not use the appliances again until they have been checked by a qualified technician.

7. Specifications

SpecificationDetail
Model NumberCO-9B
ManufacturerSprue Safety Products
Product Dimensions3 x 11 x 6.5 cm
Item Weight125 g
Power SourceBattery Powered
Batteries Required2 AA Alkaline batteries (not included)
Sensor TypeElectrochemical
Alarm Loudness85dB at 3 meters
Product Life7 years
CertificationsKitemark certified to EN 50291-1: 2010+A1:2012 and EN 50291-2:2010

8. Warranty and Support

8.1 Manufacturer's Warranty

The Fireangel CO-9B Carbon Monoxide Alarm comes with a 7-year manufacturer's warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

8.2 Customer Support

For technical assistance, warranty claims, or further information regarding your Fireangel CO-9B alarm, please visit the official Fireangel website or contact their customer support department. Contact details can typically be found on the product packaging or the manufacturer's website.

Related Documents - CO-9B

Preview FireAngel CO-9X 7 Year Life Carbon Monoxide Detector User Manual
Comprehensive user manual for the FireAngel CO-9X 7 Year Life Carbon Monoxide Poisonous Gas Alarm. Learn about installation, operation, maintenance, safety, and troubleshooting.
Preview FireAngel CO Alarms FA3313, FA3322, FA3328, FA3820 User Manual
Comprehensive user manual for FireAngel Carbon Monoxide alarms (models FA3313, FA3322, FA3328, FA3820), covering positioning, installation, CO alarm awareness, maintenance, status indicators, sleep easy feature, LCD screen indicators, and technical specifications. Includes warranty and disposal information.
Preview FireAngel Carbon Monoxide Alarm Icons Explained
A guide to understanding the various icons and indicators on your FireAngel Carbon Monoxide alarm, covering CO alarms, alarm memory, ventilation instructions, sleep mode, power status, and night-time sensing.
Preview FireAngel CO Alarms FA3313, FA3322, FA3328, FA3820 User Manual
Comprehensive user manual for FireAngel Carbon Monoxide Alarms, covering installation, positioning, alarm awareness, maintenance, status indicators, and warranty information for models FA3313, FA3322, FA3328, and FA3820.
Preview FireAngel FA6813 Carbon Monoxide Alarm User Manual
Comprehensive user manual for the FireAngel FA6813 Carbon Monoxide Alarm, covering installation, operation, maintenance, troubleshooting, and safety information.
Preview FireAngel CO-9X Carbon Monoxide Alarm User Manual
User manual for the FireAngel CO-9X 7 Year Life Carbon Monoxide Poisonous Gas Alarm. Provides information on features, installation, operation, maintenance, and troubleshooting.