Introduction
This instruction manual provides detailed guidance for the safe installation, operation, and maintenance of your Quoizel Taylor TY1716AN 3-Light 17-Inch Semi-Flush Mount Lamp. Please read all instructions carefully before beginning installation and retain this manual for future reference.
The Quoizel Taylor TY1716AN is a semi-flush mount ceiling fixture designed to provide ambient lighting. It features an antique nickel finish and an opal etched glass shade, accommodating three 100-watt bulbs.
Safety Information
- WARNING: To avoid electric shock, ensure power is turned off at the main circuit breaker or fuse box before installation or servicing.
- All electrical connections must be in accordance with local codes, ordinances, or the National Electric Code (NEC). Consult a qualified electrician if you are unfamiliar with electrical wiring.
- Use only the specified bulb type and wattage. Do not exceed the maximum wattage indicated on the fixture.
- Do not install this fixture in wet or damp locations unless specifically rated for such environments.
- Handle glass components with care to prevent breakage.
- Ensure the fixture is securely mounted to a structural element of the ceiling.
Package Contents
Verify that all components are present before beginning installation. If any parts are missing or damaged, do not attempt to assemble or install the fixture. Contact Quoizel customer service for assistance.
- Fixture Body (1)
- Opal Etched Glass Shade (1)
- Mounting Hardware Kit (includes mounting strap, screws, wire nuts) (1 set)
- Decorative Finial (1)
Note: Light bulbs are not included. This fixture requires three (3) standard base bulbs, maximum 100 watts each.
Specifications
| Model Number | TY1716AN |
| Dimensions | 11-1/2 inches (Height) x 16-1/2 inches (Diameter) |
| Material | Metal (Antique Nickel Finish), Glass (Opal Etched) |
| Bulb Type | Standard Base (E26/E27) |
| Number of Bulbs | 3 |
| Max Wattage per Bulb | 100 Watts |
| Fixture Type | Semi-Flush Mount |
| Weight | Approximately 15.5 pounds |
Setup and Installation
Before you begin, ensure you have the necessary tools: Phillips screwdriver, flathead screwdriver, wire strippers, electrical tape, and safety glasses.
- Turn Off Power: Locate the circuit breaker or fuse box that supplies power to the light fixture location. Turn off the power completely. Verify the power is off using a voltage tester.
- Prepare Mounting: Remove the old fixture if applicable. Attach the mounting strap (included in hardware kit) to the electrical junction box in the ceiling using the provided screws. Ensure it is securely fastened.
- Wiring Connections:
- Connect the black wire from the fixture to the black (hot) wire from the junction box using a wire nut.
- Connect the white wire from the fixture to the white (neutral) wire from the junction box using a wire nut.
- Connect the ground wire (bare copper or green) from the fixture to the ground wire from the junction box and to the mounting strap's ground screw.
- Carefully tuck all wires into the junction box.
- Attach Fixture Body: Align the fixture body with the mounting strap and secure it using the decorative nuts or screws provided. Ensure the fixture is flush against the ceiling.
- Install Glass Shade: Carefully place the opal etched glass shade onto the fixture. Secure it in place using the decorative finial at the bottom of the fixture. Do not overtighten.
- Install Bulbs: Screw three (3) standard base bulbs (max 100 watts each) into the sockets.
- Restore Power: Turn the power back on at the circuit breaker or fuse box. Test the light fixture.

Image: The Quoizel Taylor TY1716AN 3-Light 17-Inch Semi-Flush Mount Lamp with its antique nickel finish and opal etched glass shade. This image illustrates the assembled product.
Operating Instructions
The Quoizel Taylor TY1716AN Semi-Flush Mount Lamp is operated via a standard wall switch connected to the fixture's electrical circuit.
- To turn the light ON, flip the wall switch to the 'ON' position.
- To turn the light OFF, flip the wall switch to the 'OFF' position.
Note: If using dimmable bulbs, ensure your wall switch is a compatible dimmer switch for proper functionality.
Maintenance
Regular cleaning will help maintain the appearance and performance of your light fixture.
- Cleaning: Always turn off power to the fixture and allow it to cool before cleaning. Wipe the fixture with a soft, dry cloth. Do not use abrasive cleaners, polishes, or solvents as they may damage the finish.
- Glass Shade: The opal etched glass shade can be carefully removed and washed with mild soap and water. Rinse thoroughly and dry completely before reattaching.
- Bulb Replacement: Ensure power is off and bulbs are cool before replacing. Unscrew old bulbs and screw in new ones of the correct type and wattage (max 100W per bulb).
Troubleshooting
| Problem | Possible Cause / Solution |
|---|---|
| Light does not turn on. |
|
| Flickering light. |
|
| Glass shade is loose. |
|
Warranty and Support
Quoizel products are manufactured to high standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty card included with your purchase or visit the official Quoizel website.
For technical assistance, missing parts, or any questions regarding your Quoizel Taylor TY1716AN fixture, please contact Quoizel Customer Service:
- Website: www.quoizel.com
- Phone: Refer to the Quoizel website for current contact numbers.
Please have your model number (TY1716AN) and date of purchase available when contacting support.