SentrySafe P008E
SentrySafe SENTRY P008E Compact Electronic Safe User Manual
Model: P008E
Product Overview
The SentrySafe P008E Compact Electronic Safe provides secure storage for your important items. This portable safe features a digital keypad for easy access, along with a key override for emergency entry. Its robust steel construction and included tethering cable offer enhanced security, making it suitable for home, office, or travel use.

Key Features
- Digital Security Lock Box: Programmable electronic lock with two user codes and two override keys.
- Durable Construction: Composed of hardened, solid steel for enhanced security.
- Compact Interior: Dimensions of 1.9" H x 9.8" W x 7.1" D, providing efficient storage space.
- Steel Tethering Cable: Included for increased security, allowing the safe to be secured to a fixed object.
- Programmable Entry: Provides trustworthy security and privacy for personal belongings.
- Security Delay: Built-in 20-second time delay after three incorrect entry attempts to deter unauthorized access.
Setup
1. Battery Installation
The SentrySafe P008E requires four (4) AA alkaline batteries (not included) for the electronic lock to function. Ensure batteries are inserted with correct polarity.
- Locate the battery compartment on the underside of the safe's lid.
- Open the battery compartment cover.
- Insert four new AA alkaline batteries, matching the (+) and (-) indicators.
- Close the battery compartment cover securely.

2. Setting Your Personal Code
Upon first use, you will need to set your personal electronic access code.
- With the safe open, press the red programming button located inside the battery compartment. The yellow light on the keypad will illuminate.
- Enter your desired 3-8 digit code on the keypad.
- Press the '#' button to confirm your new code. The yellow light will flash and then turn off, indicating successful programming.
- Test your new code with the safe door open to ensure it works correctly before closing the safe.

Operating Instructions
Opening the Safe
There are two methods to open your SentrySafe P008E:
Using the Electronic Code:
- Enter your 3-8 digit personal code on the keypad.
- Press the '#' button.
- The green light will illuminate, and you will hear a click. Turn the knob clockwise to open the safe within 5 seconds.
Using the Override Key:
In case of forgotten code or dead batteries, the override key can be used.
- Insert the override key into the keyhole located on the keypad panel.
- Turn the key clockwise.
- Turn the knob clockwise to open the safe.
Changing the Electronic Code
You can change your personal code at any time.
- Open the safe.
- Press the red programming button inside the battery compartment. The yellow light will illuminate.
- Enter your new 3-8 digit code.
- Press the '#' button to confirm. The yellow light will flash and turn off.
- Test the new code with the safe open.
Using the Tethering Cable
The included steel tethering cable provides an additional layer of security by allowing you to secure the safe to a fixed object.
- Locate the tethering cable attachment point on the back of the safe.
- Thread the loop end of the cable through the attachment point.
- Wrap the cable around a secure, immovable object (e.g., a car seat frame, a desk leg).
- Pass the safe through the loop of the cable to secure it.

Maintenance
Battery Replacement
Replace batteries annually or when the keypad lights dim or fail to illuminate. Always use new AA alkaline batteries.
- If the batteries are completely drained, use the override key to open the safe.
- Follow the battery installation steps outlined in the 'Setup' section.
Cleaning
To maintain the appearance and function of your safe:
- Wipe the exterior with a soft, damp cloth. Avoid abrasive cleaners.
- Do not use harsh chemicals or solvents on the keypad or any part of the safe.
Troubleshooting
Refer to the table below for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Safe does not open with code. | Incorrect code entered; low batteries; electronic malfunction. | Re-enter code carefully. Replace batteries. Use override key. |
| Keypad beeps loudly with each press. | Normal operation. | This is an audible confirmation of button presses and cannot be disabled. |
| Safe lid does not close or lock securely. | Obstruction in the closing mechanism; misalignment; internal component issue. | Check for any objects blocking the lid. Ensure the safe is on a flat surface. If issue persists, contact customer support. |
| Override key does not work. | Key not fully inserted; internal lock issue. | Ensure the key is fully inserted and turned correctly. Do not force the key. |
Specifications
| Attribute | Detail |
|---|---|
| Brand | SentrySafe |
| Model Number | P008E |
| Lock Type | Digital with Key Override |
| Color | Black |
| Capacity | 0.08 Cubic Feet |
| Material | Alloy Steel |
| Exterior Dimensions (L x W x H) | 7.9 x 10 x 2.9 inches |
| Interior Dimensions (H x W x D) | 1.9 x 9.8 x 7.1 inches |
| Item Weight | 3.2 Pounds |
| Batteries Required | 4 AA (not included) |
| Water Resistance Level | Not Water Resistant |

Warranty and Support
Warranty Information
This SentrySafe product is covered by the manufacturer's limited warranty. Please refer to the warranty documentation included with your purchase for specific terms, conditions, and duration.
Customer Support
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SentrySafe customer support. Contact information can typically be found on the SentrySafe official website or on the product packaging.
Ask a question about this manual