Vortice 11123

Vortice Punto Filo 11123 Helical Wall Aspirator User Manual

Model: 11123

1. Introduction

Thank you for choosing the Vortice Punto Filo 11123 Helical Wall Aspirator. This product is designed for efficient air extraction in various environments, ensuring improved air quality. Constructed from UV-resistant plastic resin, it offers durability and reliable performance. This manual provides essential information for the safe and effective installation, operation, and maintenance of your aspirator.

2. Safety Information

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Electrical Safety: Ensure the power supply matches the specifications (220-240V, 50Hz). Disconnect power before any installation, maintenance, or repair work. All electrical connections must be performed by a qualified electrician and comply with local wiring regulations.
  • Installation Environment: Do not install the aspirator in areas with high humidity or where it may be exposed to direct water spray, unless specifically rated for such conditions (IPX4 protection is provided). Ensure adequate ventilation during operation.
  • Children and Vulnerable Persons: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Product Integrity: Do not modify or disassemble the aspirator. Use only original spare parts if replacement is necessary.

3. Setup and Installation

The Vortice Punto Filo 11123 is designed for wall mounting. Follow these steps for proper installation:

  1. Site Selection: Choose a suitable location on the wall, ensuring sufficient space for the unit and access for maintenance. Consider the nominal duct diameter of 100 mm for proper airflow.
  2. Mounting: Securely mount the aspirator to the wall using appropriate fasteners. Refer to the technical drawing for precise dimensions and mounting points.
  3. Ducting Connection: Connect the aspirator to the ventilation ductwork. The discharge diameter is 98 mm. Ensure a tight seal to prevent air leakage.
  4. Electrical Connection: Connect the aspirator to the main power supply (220-240V, 50Hz). Refer to the wiring diagram below for correct terminal connections. Ensure the power is off before making any connections.
Technical drawing of the Vortice Punto Filo 11123 aspirator with labeled dimensions

Figure 3.1: Technical drawing of the aspirator with labeled dimensions (A, B, C, D) for precise installation planning.

Wiring diagram for the Vortice Punto Filo 11123 aspirator

Figure 3.2: Wiring diagram for the aspirator, showing connections for power (A: terminal block) and a two-pole switch (B).

Diagram showing the aspirator installed within a wall

Figure 3.3: Diagram illustrating the aspirator installed within a wall, showing the ducting and the unit's position.

4. Operating Instructions

The Vortice Punto Filo 11123 aspirator is designed for straightforward operation.

  • Power On/Off: Once installed and wired correctly, operate the aspirator using the connected wall switch.
  • Continuous Operation: The unit is designed for continuous operation with a maximum ambient temperature of 50 °C.
The Vortice Punto Filo 11123 aspirator mounted on a wall in a modern bathroom setting

Figure 4.1: The Vortice Punto Filo 11123 aspirator mounted on a wall in a modern bathroom setting, indicating its typical application.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your aspirator. Always disconnect power before performing any maintenance.

  • Cleaning the Grille: Periodically clean the external grille to prevent dust and debris buildup, which can obstruct airflow. Use a soft, damp cloth and mild detergent. Do not use abrasive cleaners.
  • Fan Blade Cleaning: If accessible and safe to do so, carefully clean the fan blades to remove accumulated dust. Refer to the installation instructions for safe access.
  • Lubrication: The motor is equipped with self-lubricating plain bearings and does not require additional lubrication.
Front view of the Vortice Punto Filo 11123 helical wall aspirator

Figure 5.1: Front view of the Vortice Punto Filo 11123 helical wall aspirator, showing its white square grille and central fan. Regular cleaning of this grille is recommended.

6. Troubleshooting

If you encounter issues with your aspirator, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Aspirator does not turn onNo power supply
Loose wiring connection
Faulty switch
Check power outlet and circuit breaker
Verify all electrical connections (ensure power is off)
Test or replace the switch
Reduced airflowObstructed grille or duct
Fan blades are dirty
Clean the grille and check for duct obstructions
Clean the fan blades (ensure power is off)
Unusual noise during operationLoose components
Debris in fan
Motor issue
Check for loose screws or mounting
Inspect and remove any debris from fan blades
If noise persists, contact qualified service personnel

If the problem persists after attempting these solutions, please contact a qualified technician or Vortice customer support.

7. Specifications

Detailed technical specifications for the Vortice Punto Filo 11123 Helical Wall Aspirator:

  • Model: Punto Filo 11123
  • Color: White
  • Material: UV-resistant Plastic Resin
  • Nominal Duct Diameter: 100 mm
  • Discharge Diameter: 98 mm
  • Dimensions (L x W x H): 7.7 x 15.9 x 15.9 cm
  • Weight: 0.51 kg
  • Voltage: 220-240 V
  • Frequency: 50 Hz
  • Max Absorbed Power: 15 W
  • Max Absorbed Current: 0.09 A
  • Max Flow Rate: 24 L/s (85 m³/h)
  • Max Pressure: 29 Pa (3 mmH2O)
  • Acoustic Pressure Lp (at 3m): 31 dB(A)
  • RPM: 2400
  • Protection Degree: IPX4
  • Insulation Class: II°
  • Max Ambient Operating Temperature: 50 °C
  • Special Feature: Anti-backflow valve applied to the discharge mouth

8. Warranty and Support

For information regarding warranty coverage, terms, and conditions, please refer to the documentation provided with your purchase or visit the official Vortice website. For technical support, spare parts, or service inquiries, please contact your local distributor or Vortice customer service.

Manufacturer: F.lli Della Fiore Spa

Country of Origin: Italy

© 2024 Vortice. All rights reserved.