Introduction

This manual provides essential information for the safe and effective use of the Bard Dispoz-a-Bag Rectangular Leg Bag. Please read all instructions carefully before using the product. The Bard Dispoz-a-Bag is a durable and reusable medical waste bag designed for efficient and safe collection. This rectangular bag is crafted from sturdy vinyl, ensuring it can withstand multiple uses. It is specifically designed for medical waste disposal and is an essential addition to medical supplies. Easy to clean and maintain, this bag promotes a clean and safe environment.

Bard Dispoz-a-Bag Rectangular Leg Bag with straps and drainage tube

An image showing the Bard Dispoz-a-Bag Rectangular Leg Bag. The bag is translucent, rectangular, and features two sets of white straps for securing it to the leg. A green drainage tube with a clamp is visible at the bottom, and a connection port is at the top.

Key Features

Setup Instructions

1. Unpacking

  1. Carefully remove the Bard Dispoz-a-Bag from its packaging.
  2. Inspect the bag and all components (straps, tubing, clamp) for any signs of damage or defects. Do not use if damaged.

2. Attaching the Leg Bag

  1. Position the leg bag on your thigh or calf, ensuring the drainage port is at the bottom.
  2. Wrap the elastic leg straps around your leg, threading them through the designated loops on the bag.
  3. Adjust the straps to a comfortable fit. The bag should be secure enough to prevent slipping but not so tight as to restrict circulation.
  4. Ensure the bag lies flat against your leg to minimize bulk and maximize comfort.

3. Connecting to a Catheter

  1. Ensure the catheter tubing is clean and free of obstructions.
  2. Connect the catheter tubing securely to the inlet port at the top of the leg bag. Ensure a tight seal to prevent leaks.
  3. Verify that the drainage clamp on the leg bag is closed before connection to prevent immediate drainage.

Operating Instructions

1. Monitoring and Draining

  1. Regularly monitor the fill level of the leg bag. Do not allow the bag to become overly full, as this can cause discomfort or leakage.
  2. To drain the bag, position the drainage port over a toilet or suitable receptacle.
  3. Open the drainage clamp or valve to allow the contents to flow out.
  4. Once empty, close the drainage clamp or valve securely.

2. Securing the Drain Valve

After draining, always ensure the drain valve or clamp is fully closed and secured to prevent accidental leakage. A click or firm resistance usually indicates a secure closure.

Maintenance and Care

1. Cleaning the Leg Bag

  1. Disconnect the leg bag from the catheter.
  2. Rinse the inside of the bag thoroughly with cool water.
  3. Clean the bag using a mild soap and water solution. Gently scrub all surfaces, paying attention to the drainage port and inlet.
  4. Rinse again with clean water until all soap residue is removed.

2. Disinfection

  1. Prepare a disinfecting solution according to manufacturer guidelines (e.g., a solution of 1 part white vinegar to 3 parts water, or a commercial disinfectant).
  2. Pour the solution into the bag and swirl to ensure all internal surfaces are coated.
  3. Allow the solution to remain in the bag for the recommended contact time (e.g., 20-30 minutes for vinegar solution).
  4. Drain the disinfecting solution and rinse the bag thoroughly with sterile water to remove all traces of the disinfectant.

3. Storage

After cleaning and disinfection, allow the leg bag to air dry completely before storing. Store in a clean, dry place away from direct sunlight and extreme temperatures.

4. Replacement

The Bard Dispoz-a-Bag is reusable, but its lifespan depends on usage and maintenance. Inspect the bag regularly for signs of wear, cracks, or discoloration. Replace the bag immediately if any damage is observed or if it becomes difficult to clean effectively.

Troubleshooting

Common Issues and Solutions

Specifications

FeatureDetail
BrandBard
Model Number150102
Unit Count1.00 Count
Recommended UsesMedical Waste
Material FeatureReusable
ColorWhite
MaterialVinyl
Item FormBag
Number of Items1
Size1 Count (Pack of 1)
ASINB00427LDMG
Date First AvailableJune 26, 2019

Warranty and Support

For specific warranty information or technical support regarding your Bard Dispoz-a-Bag Rectangular Leg Bag, please refer to the documentation provided with your purchase or contact Bard customer service directly. Contact details can typically be found on the product packaging or the official Bard website.

Related Documents - 150102

Preview Bard Wall Mounted Packaged Air Conditioner Replacement Parts Manual - Models W18LB-A, W24LB-A, W24LB-B, W24LB-F
Comprehensive replacement parts manual for Bard Wall Mounted Packaged Air Conditioner models W18LB-A, W24LB-A, W24LB-B, and W24LB-F. Includes exploded views, parts lists, and component descriptions for cabinet, functional, control panel, and blower assembly components.
Preview Bard W12AF-A W12AF-K Wall Mounted Packaged Air Conditioner Replacement Parts Manual
Comprehensive replacement parts manual for Bard Wall Mounted Packaged Air Conditioner models W12AF-A and W12AF-K, detailing cabinet components, functional components, control panel, and blower assembly with part numbers and diagrams.
Preview Bard W12AB-A, W12AB-D, W12AB-K Wall Mounted Packaged Air Conditioner Replacement Parts Manual
Official replacement parts manual for Bard Wall Mounted Packaged Air Conditioner models W12AB-A, W12AB-D, and W12AB-K. Includes detailed diagrams and part lists for cabinet components, functional components, control panel parts, and blower assembly parts.
Preview Bard Low Voltage Control Circuit Wiring Installation Instructions
Installation manual for Bard air conditioners covering low voltage control circuit wiring for various models including W**A, W**L, W**A*D, W**L*D, and WA*S2. Details wiring diagrams, thermostat compatibility, and configuration options.
Preview Bard 11EER WA Series Wall Mount Air Conditioner Installation Instructions
Comprehensive installation guide for Bard 11EER WA Series Wall Mount Air Conditioners (Models W12AB-A, W12AB-D, W12AB-K), covering general information, installation steps, wiring, startup procedures, and service tips. Includes model nomenclature, safety practices, and technical specifications.
Preview Bard W12A2-A & W12A1-K Wall Mounted Package Air Conditioner Installation Instructions
Comprehensive installation guide for Bard W12A2-A and W12A1-K wall-mounted package air conditioners. Covers general information, mounting, wiring, startup procedures, and troubleshooting.