INOVONICS EN4204R

Inovonics EN4204R 4-Point/5-Relay Output Receiver User Manual

Model: EN4204R

Product Overview

The Inovonics EN4204R is a 4-zone add-on receiver designed with relay outputs. It facilitates the programming and supervision of up to four Inovonics wireless transmitters. This device is integral for expanding wireless security and control systems, providing reliable communication and output control.

Inovonics EN4204R 4-Point/5-Relay Output Receiver

Figure 1: Front view of the Inovonics EN4204R 4-Point/5-Relay Output Receiver. The device features a light-colored casing with a clear panel displaying the Inovonics logo, four numbered indicators (1-4), and various status icons including signal strength, alert, and power indicators. A small, rectangular access panel is visible on the lower left.

Setup and Installation

Proper setup is crucial for optimal performance of the EN4204R receiver. Follow these steps carefully:

  1. Mounting Location: Select a central location within the intended coverage area, away from large metal objects or electrical interference. Ensure the mounting surface is stable.
  2. Power Connection: Connect the receiver to a stable 1.5 Volt power source. Refer to the wiring diagram for correct polarity.
  3. Wiring Relay Outputs: Identify the five relay outputs. Wire these outputs according to your system's requirements for controlling external devices or alarm panels.
  4. Antenna Placement: Position the antenna vertically for best reception. Avoid coiling or bending the antenna wire.
  5. Enrolling Transmitters: Refer to the specific instructions for your Inovonics transmitters to enroll them with the EN4204R receiver. This typically involves placing the receiver in learn mode and activating each transmitter.
  6. Testing: After installation, thoroughly test all enrolled transmitters to ensure they communicate reliably with the receiver and that all relay outputs function as expected.

Operating Instructions

The EN4204R operates by receiving signals from paired Inovonics transmitters and activating its corresponding relay outputs. Understanding the status indicators is key to monitoring its operation.

Status Indicators:

Relay Output Functionality:

Each of the five relay outputs can be configured to respond to specific events from enrolled transmitters, such as alarms, supervisory signals, or tamper events. Consult your system's programming guide for detailed configuration options.

Maintenance

The Inovonics EN4204R receiver is designed for low maintenance. Regular checks can help ensure its continued reliability.

Troubleshooting

If you encounter issues with your EN4204R receiver, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Receiver not powering onNo power supply; incorrect voltage; faulty wiring.Verify power connection and voltage (1.5V). Check wiring for shorts or disconnections.
Transmitter not communicating with receiverTransmitter out of range; low transmitter battery; transmitter not enrolled; interference.Move transmitter closer to receiver. Replace transmitter battery. Re-enroll transmitter. Check for sources of RF interference.
Relay output not activatingIncorrect programming; faulty relay; wiring issue.Verify relay programming in your system. Check wiring to the external device. If problem persists, contact technical support.
Trouble indicator illuminatedLow battery in enrolled transmitter; supervisory fault.Identify the specific transmitter causing the fault and address its issue (e.g., replace battery). Consult your system's event log.

Specifications

Warranty Information

Inovonics products are typically covered by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Inovonics website. Keep your proof of purchase for warranty claims.

Support

For technical assistance, product inquiries, or further support, please contact Inovonics customer service. You may find contact information on the official Inovonics website or within the product packaging. When contacting support, please have your product model number (EN4204R) and serial number ready.

Related Documents - EN4204R

Preview Inovonics EN4204R Four Zone Add-On Receiver Installation Instructions
Installation instructions for the Inovonics EN4204R Four Zone Add-On Receiver with Relay Outputs, covering setup, programming, troubleshooting, and specifications for security systems.
Preview FA464DR 64-Transmitter / 16-Output Receiver Installation Instructions
This document provides installation instructions for the Inovonics FA464DR, a 64-transmitter and 16-output receiver. It covers features, technical specifications, installation, programming, troubleshooting, and warranty information.
Preview Inovonics EchoStream Wireless Security Systems and Components Product Guide
A comprehensive product guide detailing the Inovonics EchoStream line of wireless security devices, including transmitters, receivers, repeaters, and panel integration solutions for robust intrusion detection and monitoring.
Preview Inovonics EchoStream Wireless Security Products for PACOM Systems
Explore Inovonics' comprehensive range of EchoStream wireless intrusion detection devices, mobile duress buttons, repeaters, and receivers designed for seamless integration with PACOM security systems. Enhance campus-wide security with reliable wireless solutions.
Preview INOmini 660 DAB/DAB+ Monitor Receiver: Installation and User Guide
Comprehensive installation and user guide for the INOmini 660, a professional-quality off-air monitor receiver for DAB and DAB+ digital radio transmissions. Covers setup, operation, features, specifications, and firmware updates.
Preview EN4200 Security Only Serial Receiver Installation Instructions
Installation instructions for the Inovonics EN4200 Security Only Serial Receiver, detailing its overview, RF signal propagation, contact information, components, operation LEDs, installation steps, specifications, and interference guidelines.