Leviton T8380-I

Leviton T8380-I Decora Plus Duplex Surge Suppressor Receptacle Instruction Manual

Model: T8380-I | Brand: Leviton

1. Introduction

This instruction manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton T8380-I Decora Plus Duplex Surge Suppressor Receptacle. This device is designed to provide both electrical power and surge protection for connected equipment, featuring a tamper-resistant design and hospital-grade construction for enhanced safety and durability.

2. Safety Information

WARNING: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes.

Image depicting a lightning strike over a residential area, symbolizing the need for surge protection.

This image illustrates the potential for power surges, highlighting the importance of surge protection devices like the Leviton T8380-I receptacle.

3. Product Overview

The Leviton T8380-I is a 20 Amp, 125 Volt, Hospital Grade, Self-Grounding, Decora Plus Duplex Surge Suppressor Receptacle. It features a tamper-resistant design and straight blades, making it suitable for various commercial, industrial, and healthcare environments. The integrated surge protection helps safeguard sensitive electronic equipment from voltage spikes.

Front view of the Leviton T8380-I Decora Plus Duplex Surge Suppressor Receptacle in Ivory, showing the two outlets, tamper-resistant shutters, and the surge protection indicator light.

This image displays the Leviton T8380-I receptacle, highlighting its duplex design, tamper-resistant features, and the indicator light for surge protection status.

Key Features:

4. Specifications

Model NumberT8380-I
BrandLeviton
TypeDuplex Surge Suppressor Receptacle
Current Rating20 Ampere
Voltage Rating125 Volt
GradeHospital Grade, Commercial, Industrial
Configuration5-20R
Wiring TypeBack, Side Wiring
ColorIvory
MaterialPolycarbonate (PC)
ApprovalsUL 498/1449, CSA C22.2, NOM 057

5. Installation Instructions

Important: Installation must comply with all applicable electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

  1. Turn Off Power: Locate the circuit breaker or fuse that controls the outlet where you intend to install the receptacle. Turn it OFF. Verify that the power is off using a voltage tester.
  2. Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the old receptacle in place. Carefully pull the old receptacle out of the electrical box. Disconnect the wires.
  3. Prepare Wires: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires (hot, neutral, ground). Ensure wires are straight.
  4. Wire Connections:
    • Green or Bare Copper Wire (Ground): Connect to the green grounding screw on the receptacle.
    • White Wire (Neutral): Connect to the silver screw terminals.
    • Black or Colored Wire (Hot/Live): Connect to the brass screw terminals.

    Note: The Leviton T8380-I supports both back and side wiring. For side wiring, wrap the wire clockwise around the screw terminal and tighten securely. For back wiring, insert the stripped wire into the back wire hole and tighten the screw.

  5. Mount Receptacle: Carefully fold the wires into the electrical box, then secure the new receptacle to the box using the provided mounting screws.
  6. Install Wall Plate: Attach the Decora wall plate (sold separately) over the receptacle.
  7. Restore Power: Turn the power back ON at the circuit breaker or fuse box.
  8. Verify Operation: Check the surge protection indicator light. A lit green light indicates proper function. Test the outlets with a known working device.

Important Installation Note: Some surge suppressor receptacles, including certain Leviton models, may require a minimum wire length (e.g., 10 meters or 30 feet) between the electrical panel and the receptacle for optimal surge protection performance. Consult the specific installation guide included with your product for any such requirements to ensure full compliance and effectiveness.

Image showing a circuit breaker panel with a Leviton surge protection device installed, indicating proper electrical setup.

This image provides a visual context for electrical panel integration, relevant for understanding the broader electrical system where the receptacle will be installed.

6. Operating Instructions

Once installed and power is restored, the Leviton T8380-I receptacle operates like a standard duplex outlet with added surge protection. The key operational indicator is the LED light on the face of the receptacle.

To utilize the tamper-resistant feature, ensure that both prongs of a standard two-prong plug are inserted simultaneously and with even pressure. This will open the internal shutters, allowing the plug to be fully inserted.

7. Maintenance

The Leviton T8380-I receptacle requires minimal maintenance. Periodically inspect the receptacle for any signs of physical damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power at the circuit breaker and replace the unit.

Regularly check the surge protection indicator light. If the light is off, the surge protection is no longer active, and the unit should be replaced to ensure continued protection for your electronics.

Clean the surface of the receptacle with a soft, damp cloth. Do not use abrasive cleaners or solvents.

8. Troubleshooting

9. Warranty and Support

The Leviton T8380-I Decora Plus Duplex Surge Suppressor Receptacle comes with a Ten-Year Limited Product Warranty. For detailed warranty terms and conditions, please refer to the official Leviton warranty documentation or visit their website.

For technical support, product information, or warranty claims, please contact Leviton Customer Service:

Related Documents - T8380-I

Preview Installing and Testing Leviton Smart GFCI Outlet: A Comprehensive Guide
Step-by-step instructions for installing and testing Leviton Smart GFCI outlets (models D2GF1, D2GF2). Learn about GFCI functionality, wiring, troubleshooting, and safety precautions.
Preview Leviton Commercial & Industrial Grade Switches Selection Guide
A comprehensive selection guide from Leviton detailing commercial and industrial grade switches, including toggle, Decora Plus, Lev-lok, antimicrobial, and specialty switch types with application details and wiring diagrams.
Preview Leviton Decora Smart Z-Wave Outlet (ZW15R) Getting Started Guide
Comprehensive guide to installing, setting up, and customizing the Leviton Decora Smart Z-Wave Tamper-Resistant Outlet (ZW15R). Learn about Z-Wave features, network inclusion, and safety information.
Preview Leviton GFCI Outlet with USB Ports Installation and Operation Manual
Comprehensive guide for installing and operating Leviton GFCI Outlets with USB Ports, including wiring instructions, safety warnings, testing procedures, and warranty information.
Preview Leviton L-100 Catalog: Wiring Devices and Lighting Controls for Construction and Maintenance
Explore the comprehensive Leviton L-100 catalog, featuring a vast selection of high-quality wiring devices, lighting controls, and electrical solutions for industrial, commercial, and residential applications. Discover Leviton's century of innovation and commitment to quality.
Preview Leviton SmartlockPro GFCI Receptacle Installation and Testing Guide
Comprehensive guide to installing and testing Leviton SmartlockPro Ground Fault Circuit Interrupter (GFCI) receptacles. Covers safety precautions, wiring, troubleshooting, and product features.