Robertshaw 780-845

Robertshaw 780-845 Intermittent Pilot Ignition Module User Manual

Model: 780-845

1. Introduction

The Robertshaw 780-845 is an intermittent pilot ignition module designed for use with residential and commercial heating equipment. This control unit manages the ignition sequence, pilot flame monitoring, and main burner operation to ensure safe and efficient heating.

2. Safety Information

WARNING: HIGH VOLTAGE PRESENT - SHOCK HAZARD.

3. Product Overview

The Robertshaw 780-845 ignition module features 1/4-inch quick-connect electrical terminals and a universal bracket for versatile mounting. It is specifically designed for intermittent pilot ignition systems.

Robertshaw 780-845 Intermittent Pilot Ignition Module
Figure 1: Robertshaw 780-845 Intermittent Pilot Ignition Module. This image displays the top-down view of the module, showing the terminal connections, warning labels, and the green LED indicator.

Key components and indicators:

4. Setup and Installation

Before beginning installation, ensure the main power supply to the heating equipment is disconnected.

  1. Mounting: Secure the 780-845 module using its universal bracket in a suitable location within the heating equipment enclosure.
  2. Wiring: Carefully connect the electrical wires to the appropriate 1/4-inch quick-connect terminals on the module. Refer to the wiring diagram provided with your heating equipment and the labels on the module. Common connections include:
    • 24V: 24 VAC power supply.
    • TH: Thermostat input.
    • PV: Pilot Valve.
    • MV: Main Valve.
    • PV/MV: Common connection for Pilot and Main Valves.
    • Spark: Ignitor connection.
    • Sense: Flame sensor connection (if applicable for dual rod systems).
    • GND: Ground connection.
  3. Spark Gap: Ensure the spark gap for the ignitor is set to 7/64 inches.
  4. Dual Rod Ignitor/Sensor Configuration: If using a dual rod ignitor/sensor, remove and cut the factory-set jumper and utilize the dedicated sense terminal.
  5. Power Restoration: Once all connections are secure and verified, restore power to the heating equipment.

5. Operating Instructions

The 780-845 module operates automatically in response to a call for heat from the thermostat.

  1. Initiation: When the thermostat calls for heat, the control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve.
  2. Pilot Flame Recognition: Upon successful pilot flame establishment, the module recognizes the flame, stops ignition sparking, and opens the main valve portion of the gas valve, allowing the main burner to ignite.
  3. Flame Monitoring: The pilot burner flame is continuously monitored at a synchronous frequency throughout the heating cycle.
  4. Pilot Flame Failure: Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is re-established.
  5. Lockout Sequence: The 780-845 lockout ignition control provides 90 seconds of spark during an ignition attempt. This is followed by a 6-minute time delay (purge) between ignition attempts. After three unsuccessful ignition attempts, if no pilot flame is sensed, the control enters a one-hour lockout period.
  6. Lockout Reset: To reset the module after a lockout, turn the thermostat to its lowest setting and then back to the desired temperature. At the end of the one-hour lockout period, if the demand for heat is still present, the unit will automatically repeat the three ignition attempts.

6. Maintenance

The Robertshaw 780-845 ignition module itself requires no routine maintenance. However, regular maintenance of the overall heating system, including cleaning of the pilot burner and flame sensor, is recommended to ensure optimal performance and longevity of the ignition system. Always consult your heating equipment's manual for specific maintenance schedules and procedures.

7. Troubleshooting

If your heating system is not operating correctly, consider the following troubleshooting steps:

If these steps do not resolve the issue, contact a qualified HVAC technician.

8. Specifications

BrandRobertshaw
Model Number780-845
Input Voltage24 VAC, 50/60 Hz
TH Current0.250 Amp + PV + MV at 24 VAC
PV or MV Load Max1.5 Amp at 0.5 PF
Spark Gap7/64 inches
Electrical Connections1/4" Quick Connect
Dimensions4.75 x 1.5 x 3 inches
Weight14.4 ounces
Included ComponentsProduct & Instructions Guide

9. Warranty and Support

For information regarding product warranty, please refer to the documentation included with your Robertshaw 780-845 ignition module or visit the official Robertshaw website. For technical support or service inquiries, contact Robertshaw customer service or a certified HVAC professional.

Related Documents - 780-845

Preview Robertshaw Gas Valve Cross Reference Guide
A comprehensive guide to Robertshaw gas valves, including a cross-reference tool for thousands of parts. This document details various models such as manual, hydraulic, 24-volt combination, 2-stage, diaphragm, line voltage, and millivolt gas valves, providing specifications, model numbers, and applications.
Preview Robertshaw Global Product Catalog: HVACR, Cooking, and Refrigeration Controls
Explore the comprehensive Robertshaw Global Product Catalog, featuring a wide array of HVACR, cooking, and refrigeration controls from trusted brands like Ranco, Paragon, Braeburn, and Mersen. Discover thermostats, gas valves, timers, ignitors, and more for commercial and residential applications.
Preview Robertshaw RS8210 Installation Manual
Comprehensive installation manual for the Robertshaw RS8210 thermostat, covering system types, power options, wallplate installation, wiring, installer setup menu, mounting, battery installation, programming, and specifications.
Preview Robertshaw RS8110 Operation Manual
Operation manual for the Robertshaw RS8110 thermostat, covering installation, operation, temperature adjustment, calibration, and terminal designations.
Preview Robertshaw RS1110 Climate Thermostat Installation and Operation Guide
A comprehensive guide to installing and operating the Robertshaw RS1110 Climate Thermostat, covering wiring, mounting, programming, and advanced settings for efficient heating and cooling control.
Preview Robertshaw RS9423T Thermostat Installation and User Manual
Comprehensive installation, setup, and programming guide for the Robertshaw RS9423T thermostat, including system compatibility, safety warnings, wiring diagrams, technician setup options, and default program settings.