1. Introduction and Overview
The Rigol DS1052E is a high-performance 50MHz digital oscilloscope designed for precise electronic measurements. It features two channels and a maximum real-time sample rate of 1 GSa/s, with an equivalent-time sample rate of 25 GSa/s. The device is equipped with a vibrant 64k TFT color LCD for clear waveform display.
Key features include:
- 1 GSa/s maximum real-time sample rate, 25 GSa/s maximum equivalent-time sample rate
- 50 MHz Bandwidths
- 20 automatic measurements
- 64 k TFT color LCD, bright and vivid waveform display
- Ultra compact design: 303mm x 154mm x 133mm (WxHxD)

Figure 1.1: Front view of the Rigol DS1052E Digital Oscilloscope, showing the display, controls, and input ports.
2. Setup
Before operating the oscilloscope, ensure it is properly set up. Connect the power cable to the rear of the unit and plug it into a suitable power outlet. The device supports 45-440Hz AC, 100-240V 50VA MAX. Always maintain ground to avoid electric shock.

Figure 2.1: Side view of the Rigol DS1052E, highlighting the power input connector.
For initial use or to reset settings, connect the probes to the input channels (CH1, CH2) and the probe compensation output. Use the 'Auto' function to automatically adjust vertical and horizontal scales for optimal waveform display. To return to factory default settings, navigate to the 'Storage' menu, select 'Factory', and load the settings.

Figure 2.2: Rear view of the Rigol DS1052E, showing various ports including USB and RS-232.
3. Operating the Oscilloscope
The DS1052E offers various operational modes and features to capture and analyze waveforms effectively.
3.1 Auto-Run Function
The 'Auto' button automatically senses signals on the inputs and makes the best guess for time scale and vertical scaling for each signal. This is useful for quickly setting up the display for unknown signals.
3.2 Saving and Loading Waveforms
The oscilloscope supports various storage capabilities:
- Waveform: Saves the waveform data, reusable between oscilloscopes or arbitrary waveform generators.
- Setups: Saves parameters for vertical and horizontal positions, as well as triggering information.
- Bitmap: Creates a screenshot of the display, including all displayed information and menus. Can be inverted for better visibility.
- CSV: Exports data in a comma-delimited format, suitable for analysis in spreadsheet software like Excel.
- Factory: Resets the oscilloscope to its factory default settings.
To save or load data externally, insert a USB stick into the front USB port. The 'External' option will become available in the 'Storage' menu, allowing you to browse and manage files on the USB drive.
3.3 Long Memory Mode and Zoom
For detailed analysis of longer signals, the DS1052E features a long memory mode. In 'Normal' acquisition mode, the oscilloscope acquires about 16,000 points per waveform. Switching to 'Long Memory' mode (via the 'Acquire' menu) allows the acquisition of up to a million points, providing significantly higher resolution for detailed waveform examination.
To zoom into a specific area of a waveform, press the 'Horizontal' key. A zoom window will appear, allowing you to adjust the time scale and position to inspect fine details of the signal. This is particularly useful for troubleshooting complex signals where specific events need closer inspection.
3.4 Alternate Triggering
The oscilloscope can operate independently on two channels using alternate triggering. This allows you to set different trigger levels and time scales for each channel, enabling simultaneous observation and analysis of two independent signals with distinct characteristics. This is accessed through the 'Trigger' menu, by changing the mode from 'Edge' to 'Alternate'.
Video 3.1: RIGOL DS1000E Series Overview and Feature Demonstration. This video provides a visual guide to the oscilloscope's features, including auto-run, storage capabilities, long memory mode, and alternate triggering.
4. Maintenance
To ensure the longevity and optimal performance of your Rigol DS1052E oscilloscope, follow these general maintenance guidelines:
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning the exterior. Avoid abrasive cleaners or solvents.
- Ensure proper ventilation. Do not block the ventilation openings on the device.
- Store the oscilloscope in a cool, dry environment when not in use, away from direct sunlight and extreme temperatures.
- Handle probes and cables with care to prevent damage.
5. Troubleshooting
If you encounter issues with your Rigol DS1052E, consider the following common troubleshooting steps:
- Display or Signal Issues: If the display is erratic or signals are not appearing correctly, try using the 'Auto' function to re-adjust settings. If issues persist, reset the device to factory defaults via the 'Storage' menu.
- Software Compatibility: Some users have reported issues with included software requiring specific runtime environments (e.g., NIVISAruntime.msi) not provided on the installation CD. Check the official Rigol website for updated software and drivers.
- Language Settings: If the manual or on-screen messages are in an unexpected language, consult the device's settings menu to change the display language to English.
- Power Issues: Ensure the power cord is securely fitted. A loose connection can cause intermittent power.
- Fan Noise: Some units may exhibit noticeable fan noise. This is often a characteristic of the design and not indicative of a fault.
6. Specifications
| Specification | Value |
|---|---|
| Bandwidth | 50 MHz |
| Channels | 2 |
| Real-time Sample Rate | 1 GSa/s |
| Equivalent-time Sample Rate | 25 GSa/s |
| Display | 64k TFT color LCD |
| Automatic Measurements | 20 |
| Dimensions (WxHxD) | 303mm x 154mm x 133mm |
| Package Dimensions | 17 x 11 x 10 inches |
| Weight | 0.01 ounces (shipping weight may vary) |
| Manufacturer | Rigol |
| First Available Date | January 7, 2009 |
7. Warranty and Support
For warranty information, technical support, or service inquiries regarding your Rigol DS1052E oscilloscope, please contact Rigol USA directly.
Rigol USA Contact:
- Phone: 877-4-RIGOL-1
- Website: www.rigolna.com
You can also visit the official Rigol Store on Amazon for additional product information and resources.