HEWLETT PACKARD 462975-001

HP 512MB Battery Backed Write Cache Module (462975-001)

Instruction Manual

1. Introduction

This instruction manual provides essential information for the proper installation, operation, and maintenance of the HP 512MB Battery Backed Write Cache (BBWC) module, model 462975-001. This module is designed to enhance the performance and data integrity of HP SmartArray controllers by providing a temporary storage area for data before it is written to disk, and protecting this data during power outages.

Please read this manual thoroughly before proceeding with installation or operation to ensure safe and effective use of the product.

2. Safety Information

Observe the following safety precautions to prevent injury and damage to the equipment:

  • Always power off the server and disconnect all power cords before installing or removing any internal components.
  • Wear an anti-static wrist strap and work on an anti-static mat to prevent electrostatic discharge (ESD) damage to sensitive electronic components.
  • Handle the module by its edges only. Avoid touching the gold connectors or integrated circuits.
  • Ensure proper ventilation around the server to prevent overheating.

3. Package Contents

Verify that your package contains the following item:

  • HP 512MB Battery Backed Write Cache Module (462975-001)

If any components are missing or damaged, contact your vendor or HP support immediately.

4. Setup and Installation

This section details the steps for installing the 512MB BBWC module into a compatible HP SmartArray controller.

4.1 Pre-installation Checklist

  1. Ensure the server is powered off and disconnected from all power sources.
  2. Open the server chassis according to the server's service manual.
  3. Locate the HP SmartArray controller where the BBWC module will be installed. Refer to your server's documentation for the exact location.
  4. Prepare an anti-static workspace.

4.2 Module Installation

  1. Carefully remove the BBWC module from its anti-static packaging.
  2. Identify the BBWC slot on the SmartArray controller. This slot is typically a dedicated memory slot.
  3. Align the module with the slot, ensuring the gold connectors are correctly oriented. The module is keyed to fit in only one direction.
  4. Apply even pressure to both ends of the module until it is fully seated in the slot. You may hear a click as the retention clips engage.
  5. If your SmartArray controller uses a separate battery pack for the BBWC, connect the battery cable to the designated port on the controller or module. Ensure the connection is secure.
HP 512MB Battery Backed Write Cache Module, top view

Figure 1: Top view of the HP 512MB BBWC module (462975-001) showing connectors and labels.

HP 512MB Battery Backed Write Cache Module, bottom view

Figure 2: Bottom view of the HP 512MB BBWC module (462975-001) showing the circuit board.

4.3 Post-installation

  1. Close the server chassis.
  2. Reconnect all power cords and power on the server.
  3. During server boot, observe the POST messages for any errors related to the SmartArray controller or BBWC module.

5. Operating the Module

The HP 512MB BBWC module operates automatically once installed and recognized by the SmartArray controller. Its primary function is to provide a non-volatile cache for write operations, improving disk I/O performance and protecting data in the event of a power failure.

5.1 Verifying Operation

To verify the module's operational status:

  • Access the SmartArray controller's configuration utility (e.g., during server boot via a key press, or through HP's management software like HP System Management Homepage).
  • Navigate to the controller's cache settings. The 512MB BBWC should be detected and reported as active.
  • Check the battery status within the utility. A newly installed battery may require a full charge cycle.

6. Maintenance

The BBWC module itself is generally maintenance-free. However, the associated battery pack has a finite lifespan and requires periodic monitoring and eventual replacement.

6.1 Battery Monitoring

  • Regularly check the battery status through the SmartArray controller's management utility.
  • Look for warnings or errors indicating a low charge, failed battery, or battery nearing end-of-life.
  • The typical lifespan of a BBWC battery varies but is generally several years.

6.2 Battery Replacement

If the battery requires replacement:

  • Obtain a compatible replacement battery pack from HP or an authorized reseller.
  • Follow the safety precautions outlined in Section 2.
  • Power off the server and disconnect power.
  • Locate and disconnect the old battery pack.
  • Connect the new battery pack, ensuring proper orientation and secure connection.
  • Dispose of the old battery responsibly according to local regulations.
  • Power on the server and verify the new battery status in the controller utility.

7. Troubleshooting

This section provides basic troubleshooting steps for common issues.

7.1 Module Not Detected

  • Check Seating: Power off the server, open the chassis, and ensure the BBWC module is fully and correctly seated in its slot.
  • Verify Compatibility: Confirm that the module (462975-001) is compatible with your specific SmartArray controller model and server.
  • Inspect for Damage: Visually inspect the module and controller slot for any physical damage or bent pins.
  • Firmware Update: Ensure your SmartArray controller's firmware is up to date. Outdated firmware can sometimes cause detection issues.

7.2 Battery Errors

  • Check Connections: Ensure the battery cable is securely connected to both the battery pack and the controller/module.
  • Allow Charge Cycle: A new battery may take several hours to fully charge. Monitor its status over time.
  • Replace Battery: If errors persist after checking connections and allowing a charge cycle, the battery pack may be faulty and require replacement.

For more complex issues, refer to your SmartArray controller's documentation or contact HP technical support.

8. Specifications

FeatureDescription
Model Number462975-001
BrandHEWLETT PACKARD (HP)
Memory Size512 MB
TypeBattery Backed Write Cache (BBWC) Module
CompatibilityDesigned for HP SmartArray controllers (e.g., DL380 G6 cto)
Item Weight3.52 ounces (approx. 100 grams)

9. Warranty and Support

This HP product is covered by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your original server or SmartArray controller, or visit the official HP support website.

For technical assistance, product information, or to report issues, please contact HP customer support through their official channels. Have your product model number (462975-001) and server serial number ready when contacting support.

HP Support Website: www.hp.com/support

Related Documents - 462975-001

Preview HP 3458A Digital Multimeter Component-Level Information Packet
This document provides detailed component-level repair information, including schematics, component locators, and parts lists for the Hewlett-Packard (HP) 3458A Digital Multimeter. It outlines the history of repair strategies and the contents of the Component Level Information Packets (CLIPS).
Preview Hewlett-Packard HP 5382A Frequency Counter: Operating and Service Manual
This document is the operating and service manual for the Hewlett-Packard HP 5382A Frequency Counter, detailing its specifications, installation, operation, and maintenance procedures. Originally published in May 1974.
Preview HP 8657D Signal Generator: Operation and Calibration Manual
Comprehensive operation and calibration manual for the Hewlett-Packard HP 8657D π/4 DQPSK Signal Generator, detailing installation, operation, performance testing, and adjustments.
Preview HP 8657D π/4 DQPSK Signal Generator: Operation and Calibration Manual
This comprehensive manual provides detailed information on the operation, calibration, specifications, and performance testing of the Hewlett-Packard HP 8657D π/4 DQPSK Signal Generator, including Option 001.
Preview TB 9-4931-488-35: Calibration Procedure for Signal Generators
Detailed calibration procedure for Hewlett-Packard Model 8640B signal generators, including models SG1112VIU, SG1112V2U, and MIS-28707TY2, with various options. This technical bulletin provides step-by-step instructions for ensuring accurate performance.
Preview HP 8657A Synthesized Signal Generator Service Manual
Service manual for the Hewlett-Packard HP 8657A Synthesized Signal Generator, covering operation, safety, and replaceable parts with detailed listings.