Leviton 1306

Leviton 15A, 125V Snap-In Receptacle (Model 1306) Instruction Manual

1. Introduction

This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton 15A, 125V Snap-In Receptacle, Model 1306. This product is designed for panel installation and features 14 AWG, 6-inch long wire leads for connection.

Please read this manual thoroughly before beginning installation or use to ensure proper function and safety.

2. Safety Information

WARNING: Risk of Electric Shock or Fire. Improper installation or use can lead to serious injury or death. Always follow these safety guidelines:

3. Product Overview

The Leviton Model 1306 is a polarized, snap-in receptacle designed for easy panel mounting. It features a durable thermoplastic body and pre-wired 14 AWG leads for convenient electrical connection. This receptacle is suitable for various applications requiring a reliable 15A, 125V power connection.

Leviton 15A, 125V Snap-In Receptacle, Model 1306, Black

Image 1: Front view of the Leviton 15A, 125V Snap-In Receptacle (Model 1306) in black, showing the polarized outlet configuration and pre-attached wire leads.

4. Setup and Installation

Follow these steps for proper installation of the snap-in receptacle:

  1. Prepare the Installation Location: Ensure the panel opening measures approximately 0.97 inches by 0.52 inches. The panel material should be suitable for snap-in mounting.
  2. Disconnect Power: Before proceeding, turn off the power to the circuit at the main service panel. Confirm power is off using a voltage tester.
  3. Insert Receptacle: Align the receptacle with the prepared opening in the panel. Push firmly until the snap-in clips engage and the receptacle is securely seated.
  4. Wire Connections: The receptacle comes with 14 AWG, 6-inch long wire leads. Connect these leads to the appropriate circuit wiring. Ensure the polarity is correct:
    • Connect the ribbed (neutral) wire from the receptacle to the neutral (white) wire of the circuit.
    • Connect the smooth (hot) wire from the receptacle to the hot (black or colored) wire of the circuit.
    • If a ground wire is present in your application, ensure it is properly connected to the system ground.
    Use appropriate wire connectors (not included) to secure all connections.
  5. Secure Wiring: Ensure all wiring is neatly arranged and secured within the enclosure, preventing any strain on the connections or interference with other components.
  6. Restore Power: Once installation is complete and all connections are verified, restore power at the circuit breaker.
  7. Test Functionality: Plug a known working device into the newly installed receptacle to confirm proper operation.

5. Operating Instructions

The Leviton 1306 Snap-In Receptacle operates as a standard 15A, 125V electrical outlet. To use, simply plug in any compatible electrical device. Ensure the device's power requirements do not exceed the receptacle's maximum rating of 15 Amperes at 125 Volts.

This receptacle is polarized, meaning it has one slot wider than the other. Ensure that the plug of your device matches this configuration for proper and safe connection.

6. Maintenance

The Leviton 1306 Snap-In Receptacle requires minimal maintenance. Regular inspection and cleaning are recommended to ensure continued safe operation.

7. Troubleshooting

If the receptacle is not functioning correctly, consider the following troubleshooting steps:

If issues persist after troubleshooting, contact a qualified electrician for assistance.

8. Specifications

FeatureDetail
Model Number1306
Amperage15A
Voltage125V
Configuration1-15R (Polarized)
Panel Opening0.97 inch x 0.52 inch
Wire Gauge14 AWG
Wire Lead Length6 inches
MaterialThermoplastic (Face Material)
ColorBlack
Temperature Rating-40°C to 60°C
ApprovalsUL, CSA, NOM 057
Mounting TypePanel Installation (Snap-In)
Product DimensionsApproximately 6.3"L x 1.85"W (Item Package Dimension: 6.30L x 1.85W x 0.67H inches)
Item Weight0.04 Pounds (0.634 ounces)

9. Warranty Information

This Leviton product is covered by a manufacturer's warranty. For specific details regarding the warranty period, coverage, and claims process, please refer to the official Leviton website or contact Leviton customer support directly. Keep your purchase receipt as proof of purchase.

10. Support

For technical assistance, installation questions, or further product information, please contact Leviton customer support. You can typically find contact information on the official Leviton website (www.leviton.com) or on the product packaging.

When contacting support, please have your product model number (1306) and any relevant purchase information readily available.

Related Documents - 1306

Preview Leviton GFCI Receptacle Installation and Testing Guide
A comprehensive guide on how to install and test a Leviton SmartLock Pro GFCI Receptacle, including wiring instructions, safety precautions, and troubleshooting tips.
Preview Leviton GFCI Outlet with USB Ports Installation and Operation Manual
Comprehensive guide for installing and operating Leviton GFCI Outlets with USB Ports, including wiring instructions, safety warnings, testing procedures, and warranty information.
Preview Installing and Testing Leviton Smart GFCI Outlet: A Comprehensive Guide
Step-by-step instructions for installing and testing Leviton Smart GFCI outlets (models D2GF1, D2GF2). Learn about GFCI functionality, wiring, troubleshooting, and safety precautions.
Preview Leviton Decora Edge 3-Way Switch Installation Instructions
Comprehensive installation guide for the Leviton Decora Edge 3-Way (Multi-location) Switch (Model E5603), covering wiring, preparation, safety precautions, and troubleshooting.
Preview Leviton SmartlockPro GFCI Receptacle Installation and Testing Guide
Comprehensive guide to installing and testing Leviton SmartlockPro Ground Fault Circuit Interrupter (GFCI) receptacles. Covers safety precautions, wiring, troubleshooting, and product features.
Preview Leviton Indoor Plug-In Timer Instructions & Specifications (LT111, LT112, LT113, LT114)
Detailed instructions, programming guide, and specifications for Leviton Indoor Plug-In Timers, including models LT111, LT112, LT113, and LT114. Learn how to set schedules, use override functions, and understand features like Daylight Savings Time and Sunup/Sundown.