Introduction

The Danfoss RAW 5012 013G5012 Thermostatic Head with Remote Sensor is designed to provide precise and efficient temperature control for your heating system. This device is compatible with all RA 2000 series valve bodies and integrated radiator valves. It features a built-in limiter and lockable settings, allowing for customized temperature management. The remote sensor, with a capillary length of 0-2 meters, enables accurate temperature measurement away from the radiator, ensuring optimal comfort in the room. This manual provides essential information for the safe installation, operation, and maintenance of your thermostatic head.

Safety Information

Product Overview

The Danfoss RAW 5012 013G5012 thermostatic head consists of a main control unit with a temperature dial and a remote sensor connected by a capillary tube. The main unit attaches to the radiator valve body, while the remote sensor can be positioned in a location that best reflects the room's ambient temperature.

Danfoss RAW 5012 Thermostatic Head with Remote Sensor

Figure 1: Danfoss RAW 5012 Thermostatic Head with Remote Sensor. This image shows the main thermostatic head unit and the remote sensor unit.

Danfoss RAW 5012 Thermostatic Head, showing temperature dial and remote sensor connection

Figure 2: Side view of the Danfoss RAW 5012 Thermostatic Head, highlighting the temperature adjustment dial and the connection point for the remote sensor's capillary tube.

Installation

The Danfoss RAW 5012 013G5012 thermostatic head is designed for easy installation on Danfoss RA 2000 series valve bodies and integrated radiator valves. Ensure the valve body is clean and free from debris before installation.

Compatibility Check

Diagram showing compatibility with older Danfoss thermostatic heads (RAV, RAVL, RA 2000 series)

Figure 3: Compatibility chart for replacing older Danfoss thermostatic heads. The RAW 5012 is a suitable replacement for RA 2000 series valves.

Mounting the Thermostatic Head

  1. Ensure the radiator valve is in the fully open position (if adjustable).
  2. Align the thermostatic head with the valve body. The head typically has a snap-on or screw connection.
  3. Push the thermostatic head firmly onto the valve body until it clicks into place, or screw it on securely by hand. Do not overtighten.
  4. Position the remote sensor in an area that accurately reflects the room temperature, away from direct heat sources (like the radiator itself) or drafts. The capillary tube can be routed discreetly.
Diagram illustrating modern set solutions and replacement options for valve bodies

Figure 4: Illustration of modern valve body solutions and replacement options, showing how the thermostatic head integrates with the valve.

Operating Instructions

The Danfoss RAW 5012 013G5012 thermostatic head allows you to set your desired room temperature within a range of 8°C to 28°C.

Setting the Temperature

Using the Limiter and Lockable Settings

The thermostatic head includes a limiter and lockable settings to prevent unauthorized or accidental changes to the temperature range. Refer to the specific instructions provided with your valve body or contact Danfoss support for details on how to engage and disengage these features.

Maintenance

The Danfoss RAW 5012 013G5012 thermostatic head requires minimal maintenance to ensure optimal performance.

Troubleshooting

If you experience issues with your thermostatic head, consider the following common problems and solutions:

If these steps do not resolve the issue, contact Danfoss customer support or a qualified heating technician.

Specifications

FeatureSpecification
ManufacturerDanfoss
Model Number013G5012
Product Dimensions (L x W x H)13.7 x 7.7 x 6.4 cm
Weight136.08 grams
ColorWhite
Temperature Range8-28°C
Capillary Length0-2 meters
Special FeaturesRemote Sensor, Limiter, Lockable
CompatibilityDanfoss RA 2000 series valve bodies, integrated radiator valves
Components IncludedDanfoss RAW 5012 Sensor, 2m remote sensor

Warranty and Support

For warranty information, please refer to the documentation provided with your purchase or visit the official Danfoss website. Danfoss products are manufactured to high-quality standards, and specific warranty terms may vary by region and product type.

For technical support, spare parts, or further assistance, please contact Danfoss customer service through their official website or the contact details provided in your product packaging. When contacting support, please have your model number (013G5012) and purchase details readily available.

Related Documents - 013G5012

Preview Danfoss Thermostatic Radiator Sensor Type RAW | Data Sheet & Specifications
Technical data sheet for the Danfoss Thermostatic Radiator Sensor, Type RAW (models RAW 5010 and RAW 5012). Provides detailed information on application, EN 215 approval, specifications, temperature setting, mounting instructions, and dimensions for efficient radiator heating control.
Preview Danfoss Eco™ Electronic Thermostatic Radiator Head - Installation and User Manual
This guide provides comprehensive instructions for installing, setting up, and operating the Danfoss Eco™ Electronic Thermostatic Radiator Head, including technical specifications, app integration, and safety information.
Preview Danfoss EcoTM Smart Thermostat Installation and User Manual
Comprehensive guide to installing, operating, and troubleshooting the Danfoss EcoTM smart thermostat. Learn about features, app connectivity, and adapter compatibility for efficient home heating control.
Preview Danfoss EcoTM Electronic Radiator Thermostat Installation and User Guide
Comprehensive guide to installing and operating the Danfoss EcoTM electronic radiator thermostat. Learn about setup, features, app integration, temperature programming, and technical specifications for efficient home heating control.
Preview Danfoss Redia M30x1,5 with RLV-KB Installation Guide
Step-by-step installation guide for the Danfoss Redia M30x1,5 thermostatic radiator valve with RLV-KB, covering valve and sensor head attachment to radiators.
Preview Danfoss RTD Inova 3130 & 3132 Thermostatic Radiator Valve Installation and Setting Instructions
Comprehensive instructions for installing and setting Danfoss RTD Inova 3130 and 3132 thermostatic radiator valves. Covers fitting, temperature adjustment, and setting temperature limitations for optimal home heating control.