1. Introduction
This instruction manual provides essential information for the safe and effective use of your Voltcraft H40 High Voltage Probe. The H40 probe is designed for safely measuring high voltages up to 40 kV (DC or AC peak 50/60 Hz). It is an indispensable tool for applications such as determining the anode voltage of television tubes or monitors, and measuring the acceleration voltage of oscilloscopes. The probe connects to compatible measuring devices via a standard 4mm safety plug.
2. Safety Instructions
WARNING: High voltages can be lethal. Always exercise extreme caution when working with high voltage equipment. Failure to follow these safety instructions can result in serious injury or death.
- Always ensure the probe and your measuring device are in good working condition before use.
- Never exceed the maximum voltage ratings specified for the H40 probe (40 kV DC, 28 kV AC peak).
- Ensure proper grounding of the measuring device and the circuit under test.
- Always connect the ground lead of the probe to the circuit's ground before connecting the probe tip to the high voltage point.
- Disconnect the probe tip from the high voltage point before disconnecting the ground lead.
- Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses.
- Do not use the probe in wet or damp conditions.
- Avoid touching any part of the probe or the circuit under test that is not specifically designed for contact during measurement.
- If you are unsure about any aspect of high voltage measurement, seek assistance from a qualified professional.
3. Product Overview
3.1 Components
The Voltcraft H40 High Voltage Probe package includes:
- 1 x Voltcraft H40 High Voltage Probe
3.2 Features
- Safe operation for high voltage measurements.
- Measurement range: Up to 40,000 V DC and 28,000 V AC (peak, 50/60 Hz).
- Attenuation ratio: 1000:1.
- Equipped with a 4mm safety plug for secure connection to multimeters or oscilloscopes.

Image 1: The Voltcraft H40 High Voltage Probe. This image displays the long, insulated body of the probe, designed for safe handling during high voltage measurements. The 4mm safety plug connector is visible at the base, ready for connection to a compatible multimeter or oscilloscope.
4. Setup
- Prepare your measuring device: Ensure your multimeter or oscilloscope is set to the appropriate high voltage range and input impedance (typically 10 MΩ for high voltage probes). Refer to your measuring device's manual for specific settings.
- Connect the probe: Insert the 4mm safety plug of the H40 probe into the corresponding input terminal of your measuring device. Ensure a secure connection.
- Connect the ground lead: Attach the ground lead (usually a crocodile clip) from the probe to the ground reference point of the circuit you intend to measure. This connection must be made before any high voltage contact.
5. Operating Instructions
- Power off the circuit (if possible): For maximum safety, always attempt to power off the circuit before making connections. If this is not possible, proceed with extreme caution.
- Connect the ground lead: As mentioned in Setup, ensure the ground lead is securely connected to the circuit's ground.
- Apply the probe tip: Carefully touch the tip of the H40 probe to the high voltage point you wish to measure. Maintain a firm grip on the insulated body of the probe.
- Read the measurement: Observe the voltage reading on your connected multimeter or oscilloscope. Remember that the probe has an attenuation ratio of 1000:1. Therefore, the reading on your meter must be multiplied by 1000 to get the actual voltage. For example, if your meter reads 10V, the actual voltage is 10,000V (10kV).
- Remove the probe: After taking the measurement, carefully remove the probe tip from the high voltage point.
- Disconnect the ground lead: Only after the probe tip has been removed from the high voltage point, disconnect the ground lead from the circuit.
6. Maintenance
- Cleaning: Clean the probe with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the probe is completely dry before storage or next use.
- Storage: Store the probe in a clean, dry environment, away from extreme temperatures and direct sunlight.
- Inspection: Regularly inspect the probe for any signs of damage, such as cracks in the insulation, frayed cables, or bent connectors. Do not use a damaged probe.
7. Troubleshooting
If you encounter issues during operation, consider the following:
- No reading or incorrect reading:
- Check if the probe is securely connected to the measuring device.
- Ensure the ground lead is properly connected to the circuit's ground.
- Verify that your measuring device is set to the correct input and range.
- Confirm the circuit under test is powered and the high voltage point is active.
- Unstable reading:
- Ensure stable contact between the probe tip and the measurement point.
- Check for external electromagnetic interference.
8. Specifications
| Specification | Value |
|---|---|
| Brand | VOLTCRAFT |
| Model | H40 |
| Measurement Type | Multimeter Accessory (Voltage Tester) |
| Max DC Voltage | 40,000 V (40 kV) |
| Max AC Peak Voltage | 28,000 V (28 kV) at 50/60 Hz |
| Attenuation Ratio | 1000:1 |
| Connection | 4mm Safety Plug |
| Item Weight | 300 Grams |
| Power Source | Manual Operation |
| Country of Origin | Taiwan |
9. Warranty and Support
The Voltcraft H40 High Voltage Probe comes with a 3-year manufacturer's warranty.
For technical support, service, or warranty claims, please contact your retailer or visit the official VOLTCRAFT store for more information: VOLTCRAFT Store.