Intermatic PF1202T

Intermatic PF1202T Control System with Freeze Protection and Two T104M Mechanisms User Manual

Model: PF1202T

1. Introduction

The Intermatic PF1202T Control System is designed to manage pool and spa equipment operation, incorporating essential freeze protection. This system features two T104M mechanisms for precise scheduling and an adjustable thermostat to safeguard your equipment against freezing temperatures. It is suitable for installations requiring one or two time switches.

Key features of this control system include:

2. Safety Information

WARNING: To avoid serious injury or death, always disconnect power at the circuit breaker or fuse box before installing or servicing this control system. Installation and servicing should be performed by a qualified electrician in accordance with all national and local electrical codes.

3. Setup and Installation

3.1. Unpacking

Carefully remove the control system from its packaging. Inspect the unit for any signs of damage during transit. Retain all packaging materials until you have confirmed the unit is in working order.

3.2. Mounting

Mount the control system vertically on a flat, rigid surface using appropriate fasteners. Ensure the mounting location allows for proper ventilation and access for wiring and maintenance. The enclosure is designed for outdoor use.

3.3. Wiring

IMPORTANT: All wiring must be performed by a qualified electrician and comply with local and national electrical codes. The unit operates at 240 Volts and has a current rating of 17 Amps. Use appropriate gauge wiring for the load. The terminal type is screw-type for secure connections.

Refer to the wiring diagram located inside the control system's door for specific connection details. Ensure all connections are tight and secure before restoring power.

Intermatic PF1202T Control System with open door, showing two time switches and a freeze protection thermostat.

Figure 1: Intermatic PF1202T Control System with the front door open. The image displays the internal components, including two yellow time switch mechanisms at the top, each with ON/OFF levers. Below these are two blank cover plates, and on the left side, a black dial for the freeze protection thermostat, labeled with temperature settings from 32°F to 44°F. The inside of the door shows a wiring diagram and product information label.

4. Operating Instructions

4.1. Setting the T104M Time Switches

The PF1202T includes two T104M time switches to control your pool or spa equipment. Each time switch allows for independent scheduling of ON/OFF cycles.

  1. Set Current Time: Pull out the dial and rotate it clockwise until the current time aligns with the arrow on the mechanism. Push the dial back in.
  2. Set ON/OFF Times: Each time switch comes with ON (green) and OFF (red) trippers. To set an ON time, slide a green tripper onto the dial at the desired ON time. To set an OFF time, slide a red tripper onto the dial at the desired OFF time. Additional trippers can be purchased separately for more complex schedules.
  3. Manual Override: The red lever below each dial allows for manual override. Moving the lever to "ON" or "OFF" will temporarily override the programmed schedule until the next tripper engages. Ensure the lever is in the "AUTO" position for automatic operation.

4.2. Adjusting the Freeze Protection Thermostat

The integrated freeze protection thermostat automatically activates your pump and/or heater when the ambient temperature drops to a critical level, preventing freeze damage to your plumbing and equipment.

5. Maintenance

The Intermatic PF1202T Control System requires minimal maintenance. Regular inspection can help ensure long-term reliable operation.

6. Troubleshooting

This section provides solutions to common issues you may encounter with your PF1202T Control System. For problems not listed here, or if solutions do not resolve the issue, contact a qualified electrician or Intermatic customer support.

ProblemPossible CauseSolution
Equipment does not turn ON/OFF at scheduled times.
  • Incorrect time set on dial.
  • Trippers not properly installed or missing.
  • Manual override lever is engaged.
  • No power to the unit.
  • Pull out dial and rotate to current time, then push back in.
  • Ensure green (ON) and red (OFF) trippers are securely placed at desired times.
  • Set manual override lever to "AUTO".
  • Check circuit breaker and power supply.
Freeze protection not activating.
  • Thermostat set point too low.
  • Thermostat sensor obstructed or faulty.
  • No power to the unit.
  • Adjust thermostat dial to a higher temperature.
  • Clear any obstructions from the sensor. If still not working, contact support.
  • Check circuit breaker and power supply.
Unit has no power.
  • Tripped circuit breaker or blown fuse.
  • Loose wiring connection.
  • Check and reset the circuit breaker or replace the fuse.
  • With power disconnected, inspect and tighten all wiring connections.

7. Specifications

Technical specifications for the Intermatic PF1202T Control System:

FeatureDetail
BrandIntermatic
ModelPF1202T
Operation ModeON-OFF-ON
Current Rating17 Amps
Operating Voltage240 Volts
Contact TypeNormally Open
Connector TypeScrew
TerminalScrew Type
Item dimensions L x W x H6 x 12 x 14 inches
Circuit Type1-way
Actuator TypePush Button

8. Warranty and Support

Intermatic products are manufactured to high-quality standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Intermatic website.

For technical assistance, troubleshooting, or to inquire about replacement parts, please contact Intermatic customer support. Contact information can typically be found on the manufacturer's website or on the product packaging.

Related Documents - PF1202T

Preview Intermatic P1161 Portable Pool & Spa Timer Owner's Manual - Safety, Setup, and GFCI Testing
Comprehensive owner's manual for the Intermatic P1161 Portable Safety Pool & Spa Timer. Includes important safety instructions, how to set the timer, warranty information, GFCI explanation, troubleshooting guide, and monthly testing procedures.
Preview Intermatic PF1102T/PF1102MT Freeze Protection Controls: Installation, Operation & Service Manual
Comprehensive guide for installing, operating, and servicing Intermatic PF1102T and PF1102MT freeze protection controls for pools and spas. Includes safety warnings, wiring diagrams, and troubleshooting.
Preview Intermatic PF1112T Pool Equipment Control Installation, Operation & Service Manual
Comprehensive guide for the Intermatic PF1112T Pool Equipment Control, detailing installation, operation, and service. Features include freeze protection for pools and spas, a 24-hour time switch, and safety instructions.
Preview Intermatic P1131 Portable Heavy Duty Pool & Spa Timer Owner's Manual
Owner's manual for the Intermatic P1131 Portable Heavy Duty Pool & Spa Timer. Provides setup instructions, safety warnings, troubleshooting guide, and warranty information for convenient and energy-saving operation of pool and spa equipment.
Preview Intermatic PF1102/PF1102M Freeze Protection Control Installation, Operation & Service Manual
Comprehensive installation, operation, and service manual for the Intermatic PF1102 and PF1102M Freeze Protection Controls, designed for pools, spas, and water features. Includes safety instructions, wiring diagrams, troubleshooting, and warranty information.
Preview Intermatic PF1100 Series Freeze Protection Controls: Installation, Operation & Service Manual
Comprehensive guide for Intermatic PF1100 Series Freeze Protection Controls (Models PF1102T, PF1102MT, PF1103MT). Covers installation, operation, safety warnings, troubleshooting, and warranty information for pool and spa equipment.