1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your BJM Pumps R400D-115 Submersible Dewatering Pump. Please read these instructions thoroughly before operating the pump to ensure proper function and to prevent injury or damage.

The R400D-115 is a robust 0.5 HP submersible pump designed for dewatering applications, capable of pumping water down to 1/12 inch. It features a durable 304 stainless steel motor housing and a 2-inch top discharge.

2. Safety Information

WARNING: Failure to follow these safety instructions could result in electric shock, fire, serious injury, or death.

  • Always disconnect power to the pump before performing any maintenance, inspection, or service.
  • Ensure the electrical supply matches the pump's voltage (115 Volts).
  • Do not operate the pump with a damaged power cord or plug.
  • Never operate the pump in an explosive atmosphere or pump flammable liquids.
  • Keep hands and feet clear of the pump intake and discharge openings during operation.
  • This pump is designed for water only. Do not use it for chemicals, sewage, or other corrosive liquids.
  • Ensure proper grounding of the pump.

3. Product Overview

The BJM Pumps R400D-115 is engineered for efficient dewatering. Key components and features include:

  • Motor Housing: Constructed from 304 Stainless Steel for corrosion resistance.
  • Discharge: 2-inch top discharge for easy hose connection.
  • Impeller: Designed for high flow and handling small solids up to 0.125 inches in diameter.
  • Power Cable: A 33-foot power cable is provided for extended reach.
  • Mop-up Capability: Capable of pumping water down to 1/12 inch.
BJM Pumps R400D-115 Submersible Dewatering Pump

Figure 1: BJM Pumps R400D-115 Submersible Dewatering Pump. This image shows the compact design of the pump with its top discharge port and power cable.

4. Setup

Follow these steps for proper installation of your R400D-115 pump:

  1. Placement: Position the pump on a firm, level surface in the area to be dewatered. Ensure the pump is fully submerged for optimal cooling during operation.
  2. Discharge Hose Connection: Connect a suitable 2-inch discharge hose to the pump's top discharge port. Secure the hose with a clamp to prevent leaks and disconnections during operation. Ensure the hose is routed away from the pump and directs water to a safe discharge location.
  3. Electrical Connection: Plug the pump's 33-foot power cord into a grounded 115 Volt electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety. Do not use extension cords unless absolutely necessary, and if used, ensure they are rated for outdoor use and appropriate amperage.
  4. Inspection: Before starting, visually inspect the pump and power cord for any signs of damage. Ensure all connections are secure.

5. Operating Instructions

Once the pump is properly set up, follow these steps for operation:

  1. Initial Start-up: Ensure the pump is fully submerged in water. Plug the pump into the grounded 115V GFCI outlet. The pump will begin to operate immediately.
  2. Monitoring: Observe the pump's operation. It should run smoothly without excessive noise or vibration. Monitor the discharge flow to ensure water is being removed effectively.
  3. Mop-up Operation: For dewatering down to 1/12 inch, ensure the pump is placed on a flat surface. The pump will continue to run until the water level is minimal.
  4. Shut Down: To stop the pump, simply unplug it from the electrical outlet.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your R400D-115 pump.

  • Cleaning: After each use, especially if pumping dirty water, rinse the pump thoroughly with clean water. Remove any debris that may have accumulated around the intake screen or impeller area.
  • Inspection: Periodically inspect the power cord for cuts, abrasions, or other damage. Check the discharge port and impeller for blockages. Ensure all fasteners are tight.
  • Storage: When not in use, store the pump in a clean, dry location, protected from freezing temperatures.

7. Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
Pump does not startNo power to the pump
Thermal overload tripped
Impeller jammed
Check power supply and GFCI
Unplug, allow to cool, then restart
Disconnect power, clear debris from impeller
Reduced flow or no dischargeDischarge hose kinked or blocked
Intake screen blocked
Impeller worn or damaged
Check and clear hose
Disconnect power, clean intake screen
Contact qualified service personnel
Pump runs but does not pump waterPump not fully submerged
Air lock
Impeller damaged
Ensure pump is fully in water
Tilt pump to release trapped air
Contact qualified service personnel
Excessive noise or vibrationDebris in pump
Worn bearings
Improper installation
Disconnect power, clear debris
Contact qualified service personnel
Ensure pump is on a stable surface

8. Specifications

SpecificationValue
ModelR400D-115
Horsepower (HP)0.5 HP
Voltage115 Volts
Rated Amps6 Amps
RPM3,450 RPM
Discharge Size2 inches
Maximum Flow Rate55 Gallons Per Minute (GPM)
Maximum Head36 Feet
Maximum Solids Diameter0.125 inches
Cable Length33 feet
Material304 Stainless Steel (Motor Housing)
Item Weight33 Pounds
StyleSubmersible

9. Warranty and Support

For warranty information, technical support, or replacement parts, please contact BJM Pumps directly or your authorized dealer. Keep your purchase receipt as proof of purchase.

For further assistance, refer to the official BJM Pumps website or contact their customer service department.

© 2023 BJM Pumps. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.