Beurer FT15/I

Beurer FT15/I Express Thermometer User Manual

Model: FT15/I (Type 794.10)

Measurement results in 10 seconds

1. Introduction

Thank you for choosing the Beurer FT15/I Express Thermometer. This device is designed for fast and reliable body temperature measurement. Its flexible tip ensures comfortable use, and the rapid measurement time makes it ideal for all ages. Please read this manual carefully before first use and keep it for future reference.

Beurer FT15/I Express Thermometer

Image 1: The Beurer FT15/I Express Thermometer, a white and grey digital thermometer with a flexible tip and a clear LCD display showing a temperature reading.

2. Safety Information

  • This thermometer is for measuring human body temperature. Do not use it for other purposes.
  • The device contains no mercury or glass, making it safe for use.
  • Keep the thermometer out of reach of children.
  • Do not expose the thermometer to direct sunlight, high temperatures, or extreme humidity.
  • Avoid dropping the device or subjecting it to strong shocks.
  • Do not attempt to disassemble or repair the thermometer yourself.
  • If the device is damaged, do not use it. Contact customer support.
Beurer FT15/I Thermometer with safety features

Image 2: The Beurer FT15/I thermometer alongside icons indicating it is a medical product and uses a 1.5V LR41 battery. The text highlights its safe contact-measurement technology, being free of mercury or glass.

3. Product Overview

The Beurer FT15/I thermometer consists of the following main components:

  • Flexible Measuring Tip: Designed for comfortable and safe application.
  • LCD Display: Shows temperature readings and various indicators.
  • ON/OFF Button: Used to power the device on and off.
  • Battery Compartment: Located at the end of the device.
  • Protective Cover: For hygienic storage.

4. Setup and Initial Use

4.1. Battery Installation

The thermometer comes with a pre-installed 1.5V LR41 battery. If the battery symbol appears on the display, it indicates the battery needs replacement. To replace:

  1. Carefully open the battery compartment cover.
  2. Remove the old battery.
  3. Insert a new 1.5V LR41 battery with the positive (+) side facing up.
  4. Close the battery compartment cover securely.

4.2. Before First Use

Before using the thermometer for the first time, clean and disinfect the measuring tip as described in the 'Maintenance and Cleaning' section.

5. Operating Instructions

5.1. Taking a Measurement

  1. Press the ON/OFF button to turn on the thermometer. A short beep will sound, and the display will show the last measured temperature for approximately 2 seconds.
  2. The symbol '°C' or '°F' will flash, indicating the thermometer is ready for measurement.
  3. Place the flexible measuring tip according to the desired measurement method (oral, axillary, or rectal).
  4. Hold the thermometer in place until an acoustic signal (series of beeps) indicates the measurement is complete. This typically takes approximately 10 seconds.
  5. Read the temperature displayed on the LCD screen.
  6. The thermometer will automatically switch off after approximately 10 minutes of inactivity to conserve battery life. You can also manually turn it off by pressing the ON/OFF button.
Beurer FT15/I Thermometer with fast measurement details

Image 3: The Beurer FT15/I thermometer with text indicating 'When speed is of the essence - instant thermometer with fast measurement'. Icons highlight 'Express measurement approx. 10 sec.', 'Extra-flexible measuring tip', and 'Medical Temperature monitoring'.

Beurer FT15/I Thermometer flexible tip detail

Image 4: A close-up illustration of the Beurer FT15/I's extra-flexible measuring tip, demonstrating its ability to bend for comfortable and convenient temperature measurement.

5.2. Fever Indicator

The thermometer features a fever indicator. If the measured temperature is 37.8 °C (100.0 °F) or higher, the thermometer will emit a rapid series of beeps, indicating a potential fever.

Beurer FT15/I Thermometer with fever indicator and auto switch-off

Image 5: The Beurer FT15/I thermometer with icons illustrating its 'Safe use', 'Automatic switch-off', and 'Fever indicator as from 37.8 °C' features, ensuring reliable temperature measurements with an acoustic signal upon completion.

5.3. Switching Between Celsius and Fahrenheit

To switch between Celsius (°C) and Fahrenheit (°F):

  1. With the thermometer turned off, press and hold the ON/OFF button for approximately 3 seconds.
  2. The display will show the current unit (°C or °F) and then switch to the other unit. Release the button.
  3. The selected unit will be saved for future measurements.
Beurer FT15/I Thermometer with unit selection and memory

Image 6: A close-up of the Beurer FT15/I thermometer's display, showing a temperature reading. Icons indicate the ability to 'Choose to display readings in °C or °F' and that it has '1 memory space' for the last reading.

6. Maintenance and Cleaning

The Beurer FT15/I thermometer is waterproof and designed for easy cleaning and disinfection.

  • After each use, clean the measuring tip with a cotton swab or cloth moistened with 70% isopropyl alcohol.
  • You can also rinse the entire thermometer under running water.
  • Do not boil the thermometer or clean it in a dishwasher.
  • Store the thermometer in its protective cover in a cool, dry place, away from direct sunlight.
Beurer FT15/I Thermometer with waterproof feature

Image 7: The Beurer FT15/I thermometer shown with water splashing around it, emphasizing its waterproof design. Icons indicate 'Waterproof' and 'With protective cover', highlighting its easy hygiene.

7. Troubleshooting

ProblemPossible CauseSolution
Thermometer does not turn on.Battery is dead or incorrectly inserted.Replace the battery (1.5V LR41) or ensure it is inserted correctly.
Inaccurate readings.Improper placement of the tip; measurement taken too quickly; external factors.Ensure proper placement and wait for the acoustic signal. Avoid taking temperature immediately after eating, drinking, or exercising.
Display shows 'Lo' or 'Hi'.Temperature is outside the measurable range.Ensure the ambient temperature is within the operating range (10°C to 40°C / 50°F to 104°F). If 'Lo' appears after measurement, it might indicate a very low body temperature.
No acoustic signal.Measurement not complete or device malfunction.Ensure the thermometer is held steadily until the reading stabilizes. If the problem persists, contact customer support.

8. Specifications

  • Model: FT15/I (Type 794.10)
  • Measurement Range: 32.0 °C to 42.9 °C (89.6 °F to 109.2 °F)
  • Accuracy: ±0.1 °C (±0.2 °F) between 35.5 °C and 42.0 °C (95.9 °F and 107.6 °F)
  • Display: LCD Display
  • Measurement Time: Approx. 10 seconds (depending on application method)
  • Battery: 1 x 1.5V LR41
  • Battery Life: Approx. 2000 measurements
  • Automatic Switch-off: Approx. 10 minutes after last measurement
  • Dimensions: Approx. 15 x 1.2 x 2 cm
  • Weight: Approx. 0.03 g (including battery)
  • Operating Conditions: 10°C to 40°C (50°F to 104°F), 15% to 95% relative humidity (non-condensing)
  • Storage Conditions: -20°C to 60°C (-4°F to 140°F), 15% to 95% relative humidity (non-condensing)
  • Material: Plastic (flexible tip), Glass (outer material)
  • Special Features: Waterproof, flexible tip, acoustic signal, fever indicator, memory function (last reading)

9. Warranty and Support

9.1. Warranty

Beurer provides a warranty for this product. Please refer to the warranty card included with your purchase for specific terms and conditions, including the warranty period and coverage details. Keep your proof of purchase for any warranty claims.

9.2. Customer Support

If you have any questions, encounter issues, or require assistance with your Beurer FT15/I Express Thermometer, please contact Beurer customer support. Contact information can typically be found on the product packaging, the Beurer website, or the warranty card.

© 2024 Beurer GmbH. All rights reserved.

Related Documents - FT15/I

Preview Beurer FT 09/1 Digital Thermometer User Manual and Safety Information
Comprehensive guide to the Beurer FT 09/1 digital thermometer, covering safety instructions, measurement methods, usage, technical specifications, and maintenance.
Preview Beurer FT 58 Infrared Ear Thermometer User Manual
This user manual provides comprehensive instructions for operating the Beurer FT 58 Infrared Ear Thermometer. It covers device description, setup, measurement procedures for body and object temperatures, memory functions, maintenance, troubleshooting, technical specifications, and warranty information.
Preview Beurer FT 16 express Digital Thermometer - User Manual and Specifications
Comprehensive instructions for use, safety guidelines, technical specifications, and troubleshooting for the Beurer FT 16 express digital thermometer. Learn how to accurately measure body temperature orally, rectally, or axillary.
Preview Beurer FT 15/1 Digital Thermometer User Manual
Comprehensive instructions for use, safety information, technical specifications, and warranty details for the Beurer FT 15/1 digital thermometer.
Preview Beurer FT 85 Non-Contact Thermometer: Instructions for Use
Get detailed instructions for the Beurer FT 85 non-contact infrared thermometer. This guide covers setup, usage for forehead, object, and room temperatures, safety, technical data, and warranty information from Beurer GmbH.
Preview Beurer FT 90: Kontaktloses Fieberthermometer – Gebrauchsanweisung
Entdecken Sie das kontaktlose Infrarot-Fieberthermometer Beurer FT 90. Diese Gebrauchsanweisung bietet detaillierte Informationen zur sicheren und effektiven Messung der Körper-, Objekt- und Raumtemperatur.