Eaton BR48L125FP

Eaton Main Lug Load Center 125 Amp Flush 8 Circuits User Manual

Model: BR48L125FP

Eaton Main Lug Load Center and its packaging box.

This image displays the Eaton Main Lug Load Center, a gray metal electrical panel, alongside its white and black retail packaging box. The panel is shown with its cover, and the box features the 'Cutler-Hammer BR Loadcenter' branding.

Introduction

This manual provides essential instructions for the safe installation, operation, and maintenance of your Eaton Cutler-Hammer 125 Amp, 4-space, 8-circuit Flush Mount Main Lug Load Center, Model BR48L125FP. This device is designed to distribute electrical power safely within a residential or commercial setting. Please read this manual thoroughly before proceeding with any installation or operation.

Safety Information

WARNING: Electrical shock hazard. Improper installation or maintenance can result in serious injury or death. This product must be installed and serviced by a qualified electrician in accordance with all national and local electrical codes.

Setup and Installation

Installation of the Eaton BR48L125FP load center requires adherence to local electrical codes and safety standards. It is strongly recommended that installation be performed by a licensed electrician.

  1. Preparation: Turn off all power at the main service panel. Confirm power is off using a voltage tester.
  2. Mounting: Securely mount the load center enclosure to a stud or solid surface. For flush mount installations, ensure the opening in the wall is appropriately sized.
  3. Wiring the Main Lugs: Connect the main service entrance conductors to the main lugs. Ensure proper torque specifications are met for all lug connections.
  4. Grounding and Neutral: Connect the main grounding electrode conductor and neutral conductors to the designated neutral/ground bar.
  5. Circuit Breaker Installation: Install appropriate Eaton BR-type circuit breakers into the available spaces. Refer to the circuit breaker instructions for proper installation.
  6. Branch Circuit Wiring: Connect branch circuit conductors to their respective circuit breakers.
  7. Cover Installation: Once all wiring is complete and inspected, install the front cover and trim.
  8. Power Restoration: Restore power at the main service disconnect.

Operating Instructions

The Eaton Main Lug Load Center operates by distributing electrical power through individual circuit breakers. Each circuit breaker protects a specific branch circuit from overcurrents and short circuits.

Maintenance

The Eaton Main Lug Load Center is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended.

Troubleshooting

This section addresses common issues you might encounter with your load center. For complex problems, always consult a qualified electrician.

ProblemPossible CauseSolution
Circuit breaker trips frequently.Overloaded circuit, short circuit, or faulty appliance.Unplug devices from the circuit. If it still trips, consult an electrician.
No power to an entire section of the house.Main breaker tripped, or issue with utility service.Check if the main breaker is tripped. If not, contact your utility provider.
Burning smell or discoloration on the panel.Loose connection, overheating, or internal fault.Immediately turn off main power. Contact a qualified electrician. This is a serious hazard.

Specifications

Warranty Information

Specific warranty details for the Eaton BR48L125FP Load Center are typically provided with the product packaging or can be obtained directly from Eaton's official website. Generally, Eaton products come with a limited warranty covering defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

For the most current and detailed warranty information, please visit the official Eaton website or contact their customer support.

Support and Contact

For technical assistance, product inquiries, or support regarding your Eaton Main Lug Load Center, please contact Eaton customer service.

Related Documents - BR48L125FP

Preview Control Panel Design Guide According to UL 508A
A comprehensive guide to designing control panels in compliance with UL 508A standards, covering feeder mains, group motors, individual motor loads, heater/lighting circuits, power circuit wiring, and control circuits. This document provides essential information for engineers and technicians.
Preview Eaton E-VAC HV Vacuum Circuit Breaker Installation and Operating Instructions
This guide provides essential installation, operation, maintenance, and technical details for the Eaton E-VAC Enclosed Indoor High Voltage Vacuum Circuit Breaker (Model IL550-0501001E), ensuring safe and efficient use in industrial and power grid applications.
Preview Eaton Retrofit Interior Kits: Upgrade Electrical Panels Safely & Cost-Effectively
Eaton's Retrofit Interior Kits provide a cost-effective and safe solution to upgrade outdated electrical panels in homes and apartments without removing the existing enclosure. Learn about features, specifications, and ordering.
Preview Eaton Magnum LV-Air Circuit Breaker User Manual (1812.900A)
Comprehensive user manual for the Eaton Magnum LV-Air Circuit Breaker (model 1812.900A), detailing installation, operation, maintenance, troubleshooting, and renewal parts. Covers fixed and drawout configurations with electronic tripping systems.
Preview EATON 11/25 IL019140ZU Instruction Leaflet: RCCB and RCBO Installation Guide
Detailed installation instructions and technical specifications for EATON PL6, PL7, HN, PF6, PF7, and HNC series Residual Current Circuit Breakers (RCCBs) and Residual Current Breakers with Overcurrent Protection (RCBOs), including wiring diagrams and electrical data.
Preview LG & PD3 Frame Circuit Breaker Walking Beam Interlock Installation Instructions
Instruction leaflet detailing the installation, assembly, and adjustment of the Eaton LG & PD3 frame circuit breaker walking beam interlock. Includes parts list, diagrams, and safety warnings.