1. Introduction
Thank you for choosing the Cata B23-A Wall and Window Extractor Fan. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new fan. Please read these instructions carefully before use and retain them for future reference.

Figure 1: Cata B23-A Wall and Window Extractor Fan. This image shows the front view of the white extractor fan with its grille.
2. Safety Information
To ensure safe operation, always follow these basic safety precautions:
- Electrical Safety: Ensure the power supply matches the fan's specifications (230V). Disconnect power before installation, maintenance, or cleaning. All electrical connections must be performed by a qualified electrician and comply with local regulations.
- Installation: Install the fan securely on a wall or window. Ensure proper ventilation and avoid obstructing the airflow. The fan is designed for wall mounting and features an IPX4 protection type, offering splash water protection from all sides.
- Usage: Do not insert fingers or objects into the fan grille while it is operating. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Maintenance: Only perform maintenance tasks described in this manual. For complex repairs, contact qualified service personnel.
- Environment: The fan housing is made of self-extinguishing VO ABS plastic.
3. Product Overview
The Cata B23-A is a versatile extractor fan suitable for wall and window installations. It features an automatic closing flap, making it ideal for various environments such as kitchens, bathrooms, restaurants, or fast-food establishments.
Key Features:
- Automatic closing flap.
- Self-extinguishing VO ABS plastic housing.
- IPX4 splash water protection.
- Designed for wall or window mounting.
- Compatible with a separate 5-level speed regulator (B002V05F0W).
4. Setup and Installation
Before beginning installation, ensure the power supply is disconnected.
4.1 Mounting Options

Figure 2: Examples of wall and window mounting for the extractor fan. The left diagram shows the fan installed in a brick wall, and the right diagram shows it installed in a window pane.
4.2 Required Opening Dimensions
Ensure the opening for the fan is correctly sized for optimal performance and secure fitting.

Figure 3: Diagram illustrating the required cut-out dimensions for installation. For the B-23 model, a circular opening of 258-260 mm diameter is needed, centered within a 175 mm B-23 measurement from the edges.
4.3 General Installation Steps:
- Prepare the Opening: Create a circular opening in the wall or window according to the dimensions provided in Figure 3.
- Mount the Fan: Carefully insert the fan into the prepared opening. Secure it using appropriate fasteners for your wall or window material.
- Electrical Connection: Connect the fan to the main power supply (230V) following local electrical codes. Ensure all connections are secure and insulated. If using the optional speed regulator (B002V05F0W), connect it according to its specific instructions.
- Test Operation: Once installed and connected, restore power and test the fan's operation.
5. Operating Instructions
The Cata B23-A fan is designed for straightforward operation.
- Power On/Off: The fan can be turned on and off via its main power switch or through the optional speed regulator.
- Speed Control: If you have installed the compatible speed regulator (B002V05F0W, sold separately), you can select from 5 different speed levels to adjust the airflow according to your needs.
- Automatic Flap: The fan features an automatic closing flap that opens when the fan is operating and closes when it is off, preventing drafts and insect entry.
6. Maintenance
Regular cleaning and maintenance will ensure the longevity and efficient operation of your fan.
- Disconnect Power: Always disconnect the fan from the power supply before performing any cleaning or maintenance.
- Clean Exterior: Wipe the exterior of the fan housing with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Clean Grille and Blades: Carefully remove the front grille (if detachable) and gently clean the fan blades and interior surfaces to remove dust and debris. Use a soft brush or vacuum cleaner. Ensure no moisture enters the motor housing.
- Reassemble: Reattach the grille securely.
- Frequency: Clean the fan every 3-6 months, or more frequently in dusty environments.
7. Troubleshooting
If you encounter issues with your Cata B23-A fan, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on. | No power supply; loose wiring; faulty switch. | Check power connection and circuit breaker. Ensure wiring is secure. Test the switch. Consult an electrician if necessary. |
| Reduced airflow. | Blocked grille or dirty blades; obstruction in ducting. | Clean the grille and fan blades (see Maintenance section). Check for any obstructions in the ventilation path. |
| Unusual noise or vibration. | Loose mounting; foreign object in fan; worn motor bearings. | Ensure the fan is securely mounted. Disconnect power and check for foreign objects. If noise persists, contact customer support. |
| Automatic flap not closing/opening. | Obstruction; mechanism fault. | Check for any physical obstructions preventing the flap from moving freely. Clean any debris. |
If the problem persists after attempting these solutions, please contact customer support.
8. Specifications
Detailed technical specifications for the Cata B23-A Wall and Window Extractor Fan.
| Feature | Value |
|---|---|
| Brand | Cata |
| Model Name | B23-A (Internal Model: 20100180, 560251) |
| Electric Fan Design | Extractor |
| Power Source | Manual Power Supply |
| Room Type | Any room |
| Special Feature | Portable (Note: Refers to the unit's design, not necessarily ease of frequent relocation) |
| Recommended Uses | Ventilation |
| Mounting Type | Wall Mount |
| Noise Level | 49 Decibels |
| Wattage | 40 Watts |
| Number of Blades | 5 |
| Number of Speeds | 5 (with optional regulator) |
| Voltage | 230 Volts |
| Smart Home Compatibility | Not compatible with smart home systems |
| Included Components | 1 unit |
| Manufacturer | Wallair (Note: Product is branded Cata, but manufactured by Wallair) |
| ASIN | B002V08X9M |
8.1 Dimensions

Figure 4: Dimensional drawing for the B-23/RA and B-30/RA models. For the B-23/RA, dimension A is 190mm, B is 340mm, and C is 40mm. These measurements are crucial for installation planning.
| Model | A (mm) | B (mm) | C (mm) |
|---|---|---|---|
| B-23/RA | 190 | 340 | 40 |
| B-30/RA | 230 | 420 | 40 |
9. Warranty
This Cata B23-A fan is covered by a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and retailer. Please retain your proof of purchase for warranty claims. For detailed warranty information, refer to the documentation provided with your purchase or contact your retailer.
10. Customer Support
Should you require further assistance, have questions not covered in this manual, or need to report a fault, please contact your retailer or the official Cata customer service.
- Online Support: Visit the official Cata website for FAQs, product information, and contact details.
- Retailer Support: Contact the store or online platform where you purchased the product.
- Model Information: When contacting support, please provide the model number (B23-A) and ASIN (B002V08X9M) for quicker service.