FLUKE NETWORKS Fluke 1653B

Fluke 1653B Multifunction Installation Tester User Manual

Model: Fluke 1653B | Brand: FLUKE NETWORKS

1. Introduction and Overview

The Fluke 1653B is a VDE-certified multifunction installation tester designed to verify the safety of electrical installations in private, commercial, and industrial applications. This device offers a comprehensive suite of tests including insulation resistance, loop impedance, RCD/FI testing, earth resistance, and phase rotation. It features a digital display, internal memory, and a PC interface for documentation and reporting.

Key Features:

  • Digital display for clear readings.
  • Limit value display for quick pass/fail indication.
  • Insulation resistance measurement.
  • Measurement of resistances of insulating floors and walls.
  • Low-ohm measurement for continuity.
  • Earth resistance measurement.
  • Loop impedance measurement, including loop measurement without RCD/FI activation.
  • Mains voltage measurement.
  • Determination of short-circuit current/overcurrent protection installations.
  • RCD/FI testing, including type A RCDs and increasing earth current tests.
  • Phase rotation test.
  • Internal memory for storing measurement values.
  • PC interface for data transfer and reporting.
Fluke 1653B Multifunction Installation Tester, front view showing the digital display and control buttons.

Figure 1: Front view of the Fluke 1653B Multifunction Installation Tester. The device is yellow and black, featuring a large green digital display showing measurement values (e.g., 0.23 Ω and 1000 A). Control buttons such as 'TEST', 'ZERO', 'MEMORY', and function buttons (F1-F4) are visible on the left side, while a rotary dial for selecting measurement modes (e.g., Insulation, Loop, RCD, Earth, Phase Rotation, Volts) is on the right.

2. Setup

2.1. Battery Installation

The Fluke 1653B is battery-powered. Before initial use, or when the low battery indicator appears, ensure fresh batteries are installed. Refer to the battery compartment cover for correct polarity and battery type (typically AA or C cells, depending on the model variant).

  1. Locate the battery compartment on the rear of the device.
  2. Open the battery compartment cover using a screwdriver or coin if necessary.
  3. Insert the required number of batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  4. Securely close the battery compartment cover.

2.2. Initial Power On

Press the green power button (labeled with a circle and vertical line) located near the bottom left of the control panel to turn on the device. The digital display will illuminate and perform a self-test.

3. Operating Instructions

This section provides general guidance for operating the Fluke 1653B. Always refer to the on-screen prompts and safety warnings during operation.

3.1. Selecting a Measurement Function

Use the large rotary dial on the right side of the device to select the desired measurement function. The selected function will be indicated on the display.

  • VOLTS (V.): For measuring AC/DC voltage.
  • INSULATION (RISO): For insulation resistance tests.
  • CONTINUITY (RLO): For low-ohm continuity tests.
  • LOOP (ZL NO TRIP): For loop impedance measurement without tripping RCDs.
  • LOOP (ZL HI CURRENT): For high current loop impedance measurement.
  • ΔT RCD TIME: For RCD trip time measurement.
  • IΔN RCD TRIP: For RCD trip current measurement.
  • RE EARTH: For earth resistance measurement.
  • PHASE ROTATION: For determining phase sequence.

3.2. Performing a Test

Once a function is selected and test leads are connected appropriately, press the large TEST button (located on the bottom left) to initiate the measurement. The display will show the measurement result.

The ZERO button can be used to null out lead resistance for accurate low-ohm measurements.

3.3. Using Memory Functions

The device includes internal memory for storing measurement values. Use the MEMORY button and the arrow keys to navigate and save readings. Refer to the on-screen prompts for specific memory operations.

  • Press MEMORY to access memory functions.
  • Use the up/down arrow keys to scroll through stored readings or memory locations.
  • Function buttons (F1-F4) may provide additional options related to memory, such as saving, recalling, or deleting data.

3.4. PC Interface

The Fluke 1653B features a PC interface for documentation and reporting. Connect the device to a computer using the appropriate cable (sold separately) and use Fluke's software (if applicable) to download and analyze stored data.

4. Maintenance

Proper maintenance ensures the longevity and accuracy of your Fluke 1653B.

4.1. Cleaning

Clean the instrument casing with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any electrical circuits before cleaning.

4.2. Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a dry, cool place, away from direct sunlight and extreme temperatures.

4.3. Calibration

For continued accuracy, it is recommended to have the Fluke 1653B calibrated periodically by an authorized service center. Refer to Fluke's official documentation for recommended calibration intervals.

5. Troubleshooting

This section provides solutions to common issues. For more complex problems, contact Fluke customer support.

ProblemPossible CauseSolution
Device does not power on.Dead or incorrectly installed batteries.Check battery polarity; replace batteries.
Inaccurate readings.Dirty test leads; uncalibrated device; incorrect test setup.Clean test leads; consider professional calibration; review connection diagrams for the specific test.
Display shows "OL" or "OVERLOAD".Measurement range exceeded; open circuit.Ensure the measurement is within the device's specified range; check for open circuits in the test setup.
Cannot save data to memory.Memory full; incorrect procedure.Download data to PC and clear memory; review memory saving steps in the operating instructions.

6. Specifications

The following specifications are for the Fluke 1653B Multifunction Installation Tester:

  • Model Number: Fluke 1653B
  • Manufacturer: FLUKE NETWORKS
  • Certification: VDE
  • Display Type: Digital
  • Power Source: Battery-Powered
  • Color: Black/Yellow
  • Measurement Type: Multimeter (Multifunction Tester)
  • UPC: 095969460873
  • First Available Date: January 15, 2020

7. Warranty and Support

For warranty information, technical support, or service, please contact Fluke Networks directly or visit their official website. Keep your purchase receipt as proof of purchase for warranty claims.

Online Resources: For the most up-to-date information, FAQs, and software downloads, please visit the official Fluke Networks support page.

© 2024 FLUKE NETWORKS. All rights reserved. Specifications are subject to change without notice.

This manual is for informational purposes only. Always follow local electrical codes and safety regulations.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.