1. Introduction
This manual provides essential information for the safe and proper installation and use of the Crouse-Hinds LB45 Die Cast Aluminum Type LB Conduit Outlet Body. Please read these instructions thoroughly before installation and retain this manual for future reference.
2. Product Overview
The Crouse-Hinds Condulet® Series 5 Type LB conduit outlet body is designed for use in electrical conduit systems. It features a robust die-cast aluminum construction with an aluminum acrylic paint finish, ensuring durability and resistance to environmental factors. This 1-1/4 inch trade size conduit body has a capacity of 32.3 cubic inches and is NEMA 3R rated, making it suitable for outdoor use where protection against rain, sleet, and external ice formation is required.
Equipped with a threaded connection and a screw-on cover, the LB45 measures approximately 7.79 inches x 2.49 inches x 3.5 inches. Its 2-hub design makes it useful on rigid conduit, serving as a pull outlet for the installation of conductors and providing convenient openings for making splices and taps within the electrical system.

Figure 1: Crouse-Hinds LB45 Die Cast Aluminum Type LB Conduit Outlet Body. This image displays the L-shaped design with one opening on the side and another at the end, characteristic of a Type LB conduit body used for changing direction in conduit runs.
3. Specifications
- Model: LB45
- Brand: Crouse-Hinds
- Material: Die-Cast Aluminum
- Finish: Aluminum Acrylic Paint
- Trade Size: 1-1/4 inches
- Capacity: 32.3 Cubic Inches
- NEMA Rating: 3R
- Connection Type: Threaded
- Dimensions (Approximate): 7.79 inches (L) x 2.49 inches (W) x 3.5 inches (H)
- Item Weight: 14.4 ounces
- Manufacturer: Cooper Crouse-Hinds
- ASIN: B0026GL9NS
- Batteries Required: No
4. Setup and Installation
Installation of the LB45 conduit outlet body should be performed by a qualified electrician in accordance with all applicable national and local electrical codes.
Safety Precautions:
- Always disconnect power at the main service panel before installing or servicing electrical components.
- Wear appropriate personal protective equipment (PPE), including safety glasses and gloves.
- Ensure all connections are secure and properly torqued to prevent loose connections and potential hazards.
Installation Steps:
- Prepare Conduit: Ensure the ends of the rigid conduit are clean, free of burrs, and properly threaded to match the 1-1/4 inch trade size of the LB45 body.
- Thread Connection: Thread the conduit into the hubs of the LB45 conduit body. Tighten securely to ensure a proper electrical and mechanical connection. Use appropriate tools to achieve the recommended torque without over-tightening.
- Positioning: Orient the conduit body as required for the conduit run, utilizing its L-shape to change direction.
- Wire Pulling: Use the conduit body as a pull outlet to facilitate the pulling of conductors through the conduit system.
- Splices and Taps: If splices or taps are required, perform them within the conduit body, ensuring adequate space and proper insulation of all connections.
- Secure Cover: Once conductors are installed and any necessary splices or taps are made, securely attach the screw-on cover to the conduit body to maintain its NEMA 3R rating and protect the internal wiring.
5. Operating Instructions
The Crouse-Hinds LB45 conduit outlet body is a passive electrical fitting and does not have operational controls or functions in the traditional sense. Its purpose is to provide a protected enclosure for electrical conductors, facilitate changes in conduit direction, and allow for wire pulling, splicing, and tapping.
6. Maintenance
Minimal maintenance is required for the LB45 conduit outlet body. Periodic inspection is recommended to ensure its continued integrity and performance:
- Visual Inspection: Periodically check the conduit body and its connections for any signs of physical damage, corrosion, or loose covers.
- Environmental Factors: In outdoor or harsh environments, ensure that the NEMA 3R rating is maintained by verifying the cover is tightly secured and the conduit connections are sealed against moisture and dust ingress.
- Cleaning: If necessary, clean the exterior of the conduit body with a damp cloth. Avoid using abrasive cleaners or solvents that could damage the finish.
7. Troubleshooting
As a non-electrical, passive component, the LB45 conduit outlet body typically does not require troubleshooting for operational issues. Any problems encountered would generally relate to installation or physical integrity.
Common Issues and Solutions:
- Loose Cover: If the cover is loose, tighten the screws to ensure a secure fit and maintain the NEMA 3R rating.
- Corrosion: If corrosion is observed, especially in harsh environments, inspect the extent of the damage. Minor surface corrosion may be cleaned, but significant corrosion affecting structural integrity may require replacement.
- Damaged Threads: If conduit threads or conduit body threads are damaged, ensure proper sealing and connection. Damaged threads can compromise the integrity of the electrical system and may require replacement of the affected components.
For any electrical issues within the conduit system, consult a qualified electrician.
8. Warranty and Support
Information regarding specific warranty terms or direct customer support for the Crouse-Hinds LB45 Die Cast Aluminum Type LB Conduit Outlet Body is not provided within this manual. For warranty inquiries or technical support, please refer to the official Crouse-Hinds website or contact your authorized distributor.