Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Emerson 1F95-1291 7-Day Touchscreen Thermostat. This programmable thermostat offers precise temperature and humidity control, designed for compatibility with most heating, cooling, and heat pump systems, including dual fuel systems. Please read this manual thoroughly before installation and use to ensure proper function and to maximize the benefits of your new thermostat.
Safety Information
WARNING: Always turn off power to the heating/cooling system at the main fuse or circuit breaker panel before installing or servicing the thermostat. Failure to do so could result in electrical shock or equipment damage.
- This thermostat operates on 30 Volts AC.
- Installation should be performed by a qualified technician if you are unsure about wiring procedures.
- Do not short (jumper) across terminals on the gas valve or at the system control to test the thermostat. This will damage the thermostat and void the warranty.
- Ensure all wiring connections are secure and properly insulated.
Package Contents
Verify that all items are present in the package:
- Emerson 1F95-1291 Touchscreen Thermostat
- User Manual (this document)
- 2 AA Batteries
- Mounting Screws and Wall Anchors

Image: Contents of the Emerson 1F95-1291 thermostat package, showing the thermostat unit, user manual, two AA batteries, and mounting screws with wall anchors.
Setup and Installation
1. Mounting Location
Install the thermostat approximately 5 feet (1.5 meters) above the floor in an area with good air circulation, away from direct sunlight, drafts, and heat sources. Avoid locations near windows, doors, or vents that could affect temperature readings.

Image: The Emerson 1F95-1291 thermostat installed on a wall in a typical home environment, demonstrating a suitable mounting location.
2. Wiring
IMPORTANT: Turn off power to your HVAC system at the circuit breaker before proceeding with wiring. This thermostat is compatible with most single-stage, multi-stage, and heat pump systems. Refer to the wiring diagram provided with your specific HVAC system for detailed connections. If you are replacing an existing thermostat, carefully label each wire before disconnecting it.
- Remove the old thermostat.
- Mount the new thermostat base plate to the wall using the provided screws and anchors.
- Connect the wires to the corresponding terminals on the new thermostat. Ensure connections are secure.
- Snap the thermostat faceplate onto the base plate.
3. Battery Installation
This thermostat requires two (2) AA alkaline batteries for operation. Insert the batteries into the compartment on the back of the thermostat, observing the correct polarity (+/-). The thermostat will power on once batteries are installed.
4. Initial Configuration
After power is restored and batteries are installed, the thermostat will guide you through initial setup. This typically includes:
- Date and Time: Set the current date and time.
- System Type: Select your HVAC system type (e.g., Heat Pump, Conventional Furnace/AC).
- Fan Operation: Configure fan settings (e.g., Auto, On).
- Advanced Settings: Access the installer menu for specific system configurations if necessary. Consult a professional if unsure.
Operating Instructions

Image: The main display of the Emerson 1F95-1291 thermostat, indicating current room temperature (70°F), set temperature (70°F), system mode (Heat), fan status (Auto), and humidity (42%).
1. Basic Operation
- Adjusting Temperature: Use the Up and Down arrows on the touchscreen to increase or decrease the desired temperature setpoint.
- System Mode: Touch the SYSTEM button to cycle through available modes: HEAT, COOL, AUTO, OFF.
- HEAT: Only heating system operates.
- COOL: Only cooling system operates.
- AUTO: Thermostat automatically switches between heating and cooling to maintain the set temperature range.
- OFF: Heating and cooling systems are off.
- Fan Operation: Touch the FAN button to cycle through fan modes: AUTO and ON.
- AUTO: Fan runs only when heating or cooling system is active.
- ON: Fan runs continuously.
2. Programming a 7-Day Schedule
The 1F95-1291 allows for a 7-day programmable schedule, meaning you can set a unique schedule for each day of the week. This feature helps optimize energy usage.
- Touch the MENU button.
- Select SCHEDULE or PROGRAM (wording may vary slightly).
- Follow the on-screen prompts to set desired temperatures for different time periods (e.g., Wake, Leave, Return, Sleep) for each day of the week.
- Confirm and save your settings.
3. Humidity Control
This thermostat features integrated humidity control. You can set a desired humidity level, and the thermostat will activate your humidifier or dehumidifier (if connected) to maintain it.
- Touch the HUMIDITY button on the display.
- Use the Up and Down arrows to adjust the desired humidity percentage.
- The thermostat will automatically manage connected humidification/dehumidification equipment.
4. Keypad Lockout
The keypad lockout feature prevents unauthorized changes to settings. Refer to the on-screen menu or specific instructions in the full manual for activating and deactivating this feature.
Maintenance
1. Battery Replacement
When the battery indicator appears on the display, replace the two (2) AA alkaline batteries promptly to ensure continuous operation. Typically, batteries last approximately 20,000 hours (over 2 years).
- Gently pull the thermostat faceplate away from the wall plate.
- Remove the old batteries and insert new AA alkaline batteries, ensuring correct polarity.
- Snap the faceplate back onto the wall plate.
2. Cleaning
Clean the thermostat's touchscreen and casing with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or screen.
3. Filter Indicator
The thermostat may feature a filter change reminder. When this indicator appears, it is time to inspect or replace your HVAC system's air filter. Reset the indicator through the thermostat's menu after changing the filter.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Thermostat display is blank. | Dead batteries or no power to the thermostat. | Replace batteries. Check circuit breaker for HVAC system. |
| System not heating/cooling. | Incorrect system mode, setpoint issue, or HVAC system malfunction. | Verify system mode (HEAT/COOL/AUTO) and setpoint. Check if fan is set to AUTO. Ensure HVAC system is powered on. |
| Temperature reading seems inaccurate. | Thermostat location affected by drafts, direct sunlight, or heat sources. | Relocate thermostat if possible, or shield it from external influences. |
| Humidity control not working. | Humidifier/dehumidifier not connected or malfunctioning. | Check wiring to humidifier/dehumidifier. Ensure the unit itself is operational. |
| Touchscreen unresponsive or frozen. | Temporary software glitch. | Remove thermostat from wall plate and remove batteries for 30 seconds, then reinsert and reattach. |
If problems persist after attempting these solutions, contact a qualified HVAC technician or Emerson customer support for assistance.
Specifications
- Model: Emerson 1F95-1291
- Power Source: 2 AA Batteries (included), 30 Volts AC
- Display Type: LCD Touchscreen, 12 Inches
- Programmability: 7-Day Programmable
- Control Features: Temperature Control, Humidity Control (Humidifier/Dehumidifier), Auto Changeover, Filter Indicator, Keypad Lockout
- Compatibility: Most single-stage, multi-stage, and heat pump systems (including dual fuel). Not compatible with electric baseboard heat.
- Dimensions: Approximately 30"D x 8"W x 6"H (Note: These dimensions are likely for packaging. The thermostat unit itself is approximately 4.8 inches high.)
- Item Weight: 1 Pound
- Average Battery Life: 20000 Hours

Image: The Emerson 1F95-1291 thermostat held in a hand, illustrating its compact size and indicating a height of 4.8 inches (12 cm).
Warranty and Support
Emerson products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Emerson website. For technical support, troubleshooting assistance, or to locate authorized service providers, please contact Emerson customer service.
Manufacturer: Emerson Climate Technologies
Part Number: 1F95-1291