Elkay LK500

Download PDF
Contents

Elkay LK500 12" Brass P-Trap Instruction Manual

Model: LK500 | Brand: Elkay

Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Elkay LK500 12" Brass P-Trap. Please read all instructions carefully before beginning installation or use to ensure proper function and safety. The Elkay LK500 P-Trap is designed to create a water seal in your drain system, preventing sewer gases from entering your living space.

Safety Information

  • Always turn off the water supply to the sink before beginning any plumbing work.
  • Wear appropriate personal protective equipment, such as safety glasses and gloves.
  • If you are unsure about any step of the installation process, consult a qualified plumber.
  • Proposition 65 Warning: This product may expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Package Contents

Verify that all components are present before beginning installation:

  • 1 x Elkay LK500 12" Brass P-Trap with cleanout plug

Note: Additional plumbing components such as tailpieces, drain assemblies, and wall flanges are typically sold separately and may be required for a complete installation.

Specifications

Model NumberLK500
MaterialBrass (Chrome Finish)
Product Dimensions13.75 x 1.5 x 6 inches (349.25 x 38.1 x 152.4 mm)
Item Weight1.67 pounds (0.76 kg)
UPC094902036960
Dimensional drawing of the Elkay LK500 P-Trap

Figure 1: Dimensional drawing of the Elkay LK500 P-Trap, showing key measurements including a 12-inch horizontal length, 5-1/4 inch vertical drop, and 1-1/2 inch pipe diameter.

Setup and Installation

Follow these general steps for installing the Elkay LK500 P-Trap. Specific configurations may vary.

  1. Prepare the Area: Ensure the water supply to the sink is turned off. Clear the area under the sink for easy access.
  2. Remove Old P-Trap (if applicable): Place a bucket under the existing P-trap to catch any residual water. Loosen the slip nuts connecting the old P-trap to the tailpiece and the wall drain. Carefully remove the old P-trap.
  3. Inspect Components: Check all new P-trap components, including slip nuts and washers, for any damage. Ensure all sealing surfaces are clean.
  4. Assemble the P-Trap: Connect the J-bend (the curved part of the P-trap) to the trap arm (the horizontal pipe extending from the wall). Hand-tighten the slip nut with a washer.
  5. Connect to Tailpiece: Connect the top of the J-bend to the sink's tailpiece. Ensure a washer is properly seated and hand-tighten the slip nut.
  6. Connect to Wall Drain: Connect the trap arm to the wall drain pipe. Ensure a washer is properly seated and hand-tighten the slip nut.
  7. Align and Tighten: Adjust the P-trap components to ensure proper alignment and a slight downward slope towards the wall drain. Once aligned, use a wrench to gently tighten all slip nuts. Do not overtighten, as this can crack plastic components or strip threads.
  8. Test for Leaks: Turn on the water supply and run water into the sink. Carefully inspect all connections for any leaks. If leaks are present, tighten the corresponding slip nut slightly until the leak stops.
Elkay LK500 12 inch Brass P-Trap in Chrome finish

Figure 2: The Elkay LK500 12" Brass P-Trap, featuring a chrome finish and a cleanout plug at the bottom of the J-bend for easy access.

Operation

The Elkay LK500 P-Trap operates by maintaining a small amount of water in its curved section, creating a water seal. This seal prevents unpleasant sewer gases from rising through the drain and entering your home. When water drains from the sink, it flows through the P-trap, replenishing the water seal. Regular use of the sink helps maintain this seal.

Maintenance

  • Regular Cleaning: Periodically flush the drain with hot water to help prevent grease and soap scum buildup. Avoid pouring harsh chemicals down the drain, as they can damage plumbing components.
  • Cleanout Plug: The LK500 P-trap is equipped with a cleanout plug at the bottom of the J-bend. If a clog occurs, place a bucket underneath, then carefully unscrew the cleanout plug to access and remove debris. Re-tighten the plug securely after cleaning.
  • Check for Leaks: Periodically inspect the P-trap connections for any signs of leaks, such as drips or water stains. Address any leaks promptly by tightening slip nuts or replacing worn washers.
  • Prevent Dry Traps: If a sink is not used for an extended period, the water in the P-trap can evaporate, breaking the seal. Run water for a minute or two every few weeks to replenish the water seal.

Troubleshooting

  • Slow Drain:
    • Cause: Partial clog in the P-trap or drain line.
    • Solution: Use the cleanout plug to remove debris. If the clog persists, a drain snake may be needed.
  • Foul Odors from Drain:
    • Cause: Dry P-trap (water seal evaporated) or debris buildup.
    • Solution: Run water for a minute to replenish the seal. Clean the P-trap using the cleanout plug if odors persist.
  • Leaks at Connections:
    • Cause: Loose slip nuts or worn/improperly seated washers.
    • Solution: Gently tighten slip nuts. If leaks continue, disassemble the connection, inspect washers for damage, and replace if necessary. Ensure washers are correctly seated.

Warranty Information

Elkay products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions applicable to your Elkay LK500 P-Trap, please refer to the warranty documentation included with your purchase or visit the official Elkay website. Keep your proof of purchase for warranty claims.

Customer Support

For further assistance, technical support, or to inquire about replacement parts, please contact Elkay customer service. You can find contact information and additional resources by visiting the official Elkay website:

Visit the Elkay Store on Amazon

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.