Woods 59382 Outdoor Heavy Duty Timer

Instruction Manual

Introduction

This manual provides detailed instructions for the safe and effective use of your Woods 59382 15-Amp 3-Prong Outdoor Heavy Duty Timer. This mechanical timer is designed for outdoor use, offering daily programming with up to 48 on/off settings to automate electrical devices.

Important Safety Instructions

Please read and understand all safety instructions before operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • DO NOT SUBMERGE IN WATER. This timer is weather-resistant but not submersible.
  • DO NOT EXCEED RATED CAPACITY. Overloading the timer can cause overheating and fire. Refer to the Specifications section for maximum load ratings.
  • Always use a 3-conductor, GFCI-protected outdoor outlet for connection.
  • This device must be mounted in a vertical position with the receptacle facing downwards. Ensure the receptacle does not reach ground level to prevent water accumulation.
  • Ensure the timer is securely mounted to prevent accidental dislodgement.
  • Unplug the timer from the power source before performing any adjustments or maintenance.
Woods 59382 Outdoor Timer Instruction Manual Page
Image 1: Original instruction manual page for Woods 59382 timer, detailing safety and setup instructions.

Setup Instructions

Follow these steps for initial setup of your Woods 59382 timer:

  1. Adjust Timer Dial: Rotate the timer dial until the present time aligns with the arrow head pointer. The dial is marked with AM/PM indicators.
  2. Set ON/OFF Times: The timer dial has small segment pins around its circumference. Each pin represents a 15-minute interval.
    • To set an "ON" period, push the corresponding segment pins down.
    • To set an "OFF" period, pull the corresponding segment pins up.

    Note: The pins may be stiff; use a small, non-metallic pointed object if necessary.

  3. Set Manual Override Switch: Locate the manual override switch. Set it to the "ON" position for initial setup.
  4. Plug In Timer: Switch the unit to the "ON" position and plug the timer into a 3-prong, GFCI-protected outdoor wall receptacle.

Important Considerations for Plugging In:

  • If using an outdoor extension cord, plug it into your timer's receptacle.
  • If not using an outdoor extension cord, plug your outdoor lights (e.g., Christmas lights) directly into the timer's receptacle.
  • The total cumulative wattage of all connected lights must not exceed 500W.
  • For optimal performance and to prevent snow accumulation, plug your timer directly into a wall receptacle that is at least 1 or 2 feet above the ground with outlets facing down.
Woods 59382 Outdoor Timer Front View
Image 2: Front view of the Woods 59382 timer, showing the dial and segment pins for programming.
Woods 59382 Outdoor Timer with Power Cord and Outlets
Image 3: The Woods 59382 outdoor timer, illustrating its power cord and integrated outlets.

Operating Instructions

Once programmed, the Woods 59382 timer will automatically repeat its settings daily.

  • The timer provides up to 48 on/off settings per day, allowing for precise control of connected devices.
  • To temporarily override the current programmed settings (e.g., to turn a device on or off outside of its scheduled time), simply push the manual override switch.

Maintenance

The Woods 59382 timer requires minimal maintenance. To ensure longevity and proper function:

  • Periodically inspect the timer and its cord for any signs of damage, wear, or fraying.
  • Keep the timer clean and free from dirt, dust, and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Ensure the protective cover is securely closed when not accessing the dial to protect against elements.

Troubleshooting

If your timer is not functioning as expected, consider the following:

  • Device not turning ON/OFF: Check if the segment pins are correctly pushed down for "ON" times and pulled up for "OFF" times. Ensure the manual override switch is in the desired position.
  • Timer not receiving power: Verify that the wall outlet is functional and providing power. Check the timer's plug for a secure connection. Ensure the GFCI outlet has not tripped.
  • Incorrect timing: Re-check that the present time is accurately aligned with the arrow head pointer on the dial.
  • Overload: If the connected device is not working, ensure its wattage does not exceed the timer's rated capacity (1875W Resistive, 500W Tungsten).

Specifications

FeatureSpecification
Model Number59382
Voltage125 Volts
Frequency60 Hz
Resistive Load (General Purpose)15 Amps, 1875 Watts
Tungsten Load (Lighting)4 Amps, 500 Watts
Fluorescent Load (Ballast)8 Amps, 625 VA
Motor Load1 Horsepower (HP)
Cord Type6-inch 14/3 SJTW Power Supply Cord
Daily SettingsUp to 48 ON/OFF settings (15-minute intervals)
CertificationCSA

Warranty Information

This Woods product is warranted against any defects in material or workmanship. For specific warranty terms and conditions, please refer to the product packaging or contact Woods customer service.

Support

For further assistance, technical support, or to inquire about replacement parts, please contact Woods customer service. Contact information can typically be found on the product packaging or the official Woods website.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.