Middle Atlantic EWR-10-17

Middle Atlantic EWR-10-17 10U 17-inch Deep EWR Series Economical Pivoting Wall Rack User Manual

Model: EWR-10-17

Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Middle Atlantic EWR-10-17 10U 17-inch Deep EWR Series Economical Pivoting Wall Rack. This wall-mount rack is designed to house and organize various electronic equipment, offering a pivoting mechanism for easy access to the rear of installed components.

Safety Information

Please read and understand all safety instructions before installing or operating this product. Failure to follow these instructions may result in injury or damage to the equipment.

  • Ensure the mounting surface can support the combined weight of the rack and all installed equipment. The rack has a weight capacity of 250 pounds.
  • Always use appropriate tools and safety gear during installation.
  • Distribute equipment weight evenly within the rack to maintain stability.
  • Do not overload the rack beyond its specified weight capacity.
  • Keep hands clear of pivoting sections during operation to prevent pinching.
  • Ensure proper ventilation to prevent equipment overheating. The rack is vented for passive thermal management.

Package Contents

Verify that all components are present before beginning installation:

  • EWR-10-17 Pivoting Wall Rack (Backpan and Center Section)
  • Mounting Hardware (typically included, refer to packaging for specifics)
  • Instruction Sheet (this document)

Note: Optional front doors are sold separately.

Setup and Installation

The EWR-10-17 rack features a tool-free Quick-Mount system designed for efficient one-person installation of the center section onto the backpan.

  1. Mounting the Backpan:

    Secure the backpan to a suitable wall surface using appropriate fasteners (not included). Ensure the mounting surface is structurally sound and capable of supporting the rack's maximum load of 250 pounds. The backpan includes integral mounting clips for power strips.

    Utilize the electrical knockouts (0.5”, 0.75”, 1”, 1.5”) and the 10.5'' x 10.5'' pull-box as needed for cable management.

  2. Attaching the Center Section:

    Align the center section with the mounted backpan. The Quick-Mount system allows for easy, tool-free attachment. Ensure the center section is securely engaged with the backpan's mounting clips.

  3. Installing Rack Equipment:

    The rack features standard 11-gauge, 10-32 threaded rackrail with marked rackspace increments. These rackrails are adjustable to three positions: 0.13'', 0.63'', and 1.13'' depth. Mount your equipment using 10-32 rack screws (not included), ensuring even weight distribution.

  4. Securing the Rack:

    The center section is reversible and padlockable, keyed separately from any optional front door. Ensure the center section is securely latched and locked if desired.

Operating the Pivoting Mechanism

The EWR Series rack is designed to pivot away from the wall, providing convenient access to the rear of installed equipment for cabling and maintenance.

  1. Unlocking: If the center section is locked, use the appropriate key to unlock it.
  2. Pivoting: Carefully pull the center section away from the wall. The pivoting mechanism will allow it to swing open. Support the weight of the rack and equipment during this process.
  3. Access: Once pivoted, you will have full access to the rear of your rack-mounted devices.
  4. Closing: Gently push the center section back towards the wall until it latches securely. Lock the section if required.

Caution: Always ensure the rack is stable and equipment is secure before pivoting. Avoid sudden movements.

Maintenance

Regular maintenance ensures the longevity and proper function of your EWR-10-17 rack.

  • Cleaning: Wipe down the exterior surfaces with a soft, damp cloth. Avoid abrasive cleaners or solvents.
  • Inspection: Periodically check all mounting hardware and rack screws for tightness. Ensure the pivoting mechanism operates smoothly and without excessive play.
  • Ventilation: Ensure that the rack's ventilation openings are not obstructed to maintain optimal passive thermal management.

Troubleshooting

This section addresses common issues you might encounter.

  • Rack not pivoting smoothly: Check for obstructions or debris in the pivoting mechanism. Ensure all equipment is properly seated and not interfering with movement.
  • Equipment not fitting: Verify that your equipment is standard 19-inch rack-mountable and that you are using the correct rack screws (10-32 threaded). Check the rackrail depth adjustment.
  • Rack feels unstable: Re-check all wall mounting fasteners and ensure they are securely tightened. Confirm that the center section is fully engaged with the backpan. Ensure equipment weight is evenly distributed.

Specifications

Model NumberEWR-10-17
Rack Spaces10U
Overall Depth17 inches
Interior Depth15 inches
Overall Height (10U)24.5 inches
Overall Width23.4 inches
Weight Capacity250 pounds
Item Weight58 pounds
MaterialMetal
FinishBlack
Mounting Type10-32 threaded
Rackrail Adjustment0.13'', 0.63'', 1.13''
Thermal ManagementPassive (Vented)
Electrical Knockouts0.5”, 0.75”, 1”, 1.5”
Pull-box Dimensions10.5'' x 10.5''

Warranty and Support

For warranty information and technical support, please contact Middle Atlantic Products directly or refer to their official website. Keep your purchase receipt for warranty claims.

Middle Atlantic Products Contact Information:

Related Documents - EWR-10-17

Preview Middle Atlantic NEXSYS UPS RackLink Network Card Quick Start Guide
Quick start guide for the Middle Atlantic NEXSYS UPS RackLink Network Card (Model 100-00073 RevA), detailing installation, feature set, network access, and configuration for UPS systems.
Preview Middle Atlantic NEXSYS UPS Communication Protocol User Manual
This user manual details the communication protocol for Middle Atlantic NEXSYS UPS systems, covering TCP/IP and SSH interfaces, command structures, control commands, and status read commands for remote management and monitoring.
Preview Middle Atlantic Select Series PDU with RackLink User Manual
Comprehensive user manual for the Middle Atlantic Select Series PDU with RackLink, detailing installation, configuration, and operation. Includes safety instructions, feature sets for various models, and troubleshooting.
Preview Middle Atlantic NEXSYS Series Rackmount PDU User Manual (Model 100-00060)
Comprehensive user manual for the Middle Atlantic NEXSYS Series Rackmount PDU, covering installation, features, specifications, and warranty for models PDX-915R, PDX-920R, PDX-915R-SP, and PDX-920R-SP.
Preview Middle Atlantic Select Series PDU with RackLink Quick Start Guide
A concise guide to installing and setting up the Middle Atlantic Select Series PDU with RackLink, covering features, components, network configuration, and troubleshooting.
Preview Middle Atlantic NEXSYS Rackmount PDUs: Features, Specifications, and Models
Comprehensive overview of Middle Atlantic NEXSYS Rackmount Power Distribution Units (PDUs), detailing features, surge protection options (Multi-Stage MOV and Series Surge), technical specifications, model variations (PDX-915R, PDX-920R, PDX-915R-SP, PDX-920R-SP), physical dimensions, and warranty information.