Elk ELKSS15

ELK Self-Contained Exterior Siren (ELK-SS15) Instruction Manual

Model: ELK-SS15

1. Product Overview

The ELK-SS15 is a self-contained exterior siren designed to provide audible alerts for security systems. It features two distinct tones, Yelp and Steady, and is capable of producing a sound output of 110 dB. This unit is suitable for outdoor installation and is built to withstand various environmental conditions.

ELK-SS15 Self-Contained Exterior Siren

Figure 1: ELK-SS15 Self-Contained Exterior Siren. This image shows the white horn-shaped siren with a black mounting bracket and exposed wiring at the base.

2. Safety Information

Please read and understand all safety instructions before installing or operating the ELK-SS15 siren. Failure to follow these instructions may result in electric shock, fire, or other hazards.

3. Package Contents

Verify that all items are present in the package:

4. Setup and Installation

The ELK-SS15 siren is designed for wall mounting. Follow these steps for proper installation:

  1. Choose a Location: Select an outdoor location that provides optimal sound coverage and is protected from direct physical impact. Ensure the mounting surface is sturdy.
  2. Mounting:
    • Position the siren's mounting bracket against the desired surface.
    • Mark the drilling points through the holes in the bracket.
    • Drill pilot holes if necessary, suitable for the mounting screws.
    • Secure the siren to the surface using appropriate screws and anchors (not always included).
  3. Wiring:

    The ELK-SS15 requires a power source (typically 12V DC from a security control panel) and a trigger input. Refer to your security system's manual for specific wiring diagrams.

    • Connect the positive (+) wire from your control panel's siren output to the siren's positive input.
    • Connect the negative (-) wire from your control panel's common ground to the siren's negative input.
    • If applicable, connect the trigger wire for tone selection (Yelp/Steady) as per your security system's specifications. Consult the siren's wiring diagram for specific color codes.

    Note: Ensure all connections are secure and insulated to prevent short circuits and corrosion.

  4. Testing: After installation, test the siren's functionality by activating your security system's alarm. Ensure the siren activates and produces the desired tone.

5. Operating Instructions

The ELK-SS15 siren operates in conjunction with a compatible security alarm control panel. It does not have independent controls.

6. Maintenance

The ELK-SS15 siren is designed for low maintenance. Regular checks can ensure optimal performance:

7. Troubleshooting

If the ELK-SS15 siren is not functioning as expected, consider the following:

ProblemPossible CauseSolution
Siren does not activate.No power, loose wiring, faulty control panel output, incorrect wiring.Check power supply to the siren. Verify all wiring connections are secure and correct. Test the alarm control panel's siren output.
Siren is too quiet or distorted.Low power, internal damage, obstruction.Ensure adequate power supply. Inspect for physical damage or obstructions. If problem persists, the unit may need replacement.
Siren activates unexpectedly.Faulty alarm control panel, wiring short.Consult your alarm control panel's manual for troubleshooting unexpected activations. Check siren wiring for any shorts.

If troubleshooting steps do not resolve the issue, contact a qualified security system technician or ELK Products Inc. support.

8. Specifications

FeatureDetail
Model NumberELK-SS15
ManufacturerElk Products Inc.
Sound Output110 dB
TonesYelp, Steady
Power SourceExternal DC Power (typically from a security alarm control panel)
Mounting TypeWall Mount
ColorWhite
Product Dimensions (L x W x H)7.5 x 6.5 x 5.5 inches
Item Weight0.01 ounces
UPC762158100154

9. Warranty and Support

Specific warranty information for the ELK-SS15 siren is typically provided at the point of purchase or through the manufacturer's official documentation. For detailed warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Elk Products Inc. website.

For technical support, installation assistance, or further inquiries, please contact Elk Products Inc. directly. Contact information can usually be found on their official website or on the product packaging.

Note: This product is designed to be integrated into a security system. For issues related to the overall security system, please contact your alarm system installer or service provider.

Related Documents - ELKSS15

Preview ELK M1EZ8: Installation and Programming Manual
Comprehensive guide for installing and programming the ELK M1EZ8 Cross Platform Control security system, covering setup, features, and SIA CP-01 compliance.
Preview ELK-6021 Wireless Mini Window Sensor: Installation and Operation Guide
Comprehensive guide for the ELK-6021 Wireless Mini Window Sensor, covering installation, programming, testing, and specifications. Learn how to integrate this two-way wireless sensor into your security system.
Preview ELK-M1XSLC Interface Kit: Lutron Caséta & Homeworks QS Integration Guide
Learn how to integrate Elk M1 security systems with Lutron Caséta Wireless and Homeworks QS using the ELK-M1XSLC interface kit. This guide covers setup, configuration, and control of smart home devices.
Preview ELK-M1XRF319 Wireless Receiver and Input Expander Installation Manual
Installation manual for the ELK-M1XRF319 Wireless Receiver and Input Expander, detailing setup, operation, compatible transmitters, and configuration options for 319.5MHz frequency systems.
Preview ELK-M1XSP Installation Manual: Lighting, Thermostat, and Serial Port Expander
This installation manual provides comprehensive guidance for the ELK-M1XSP, a versatile device serving as a lighting interface, thermostat interface, and serial port expander. It details setup, configuration, jumper settings, compatibility with various systems like Aprilaire, RCS, HAI, OnQ-ALC, UPB, Centralite, Lutron, Insteon, Uplink AnyNET, W800RF32, and AES Intellinet, and essential data bus termination procedures for the ELK-M1 and M1EZ8 control systems.