Introduction
This manual provides detailed instructions for the safe installation, operation, and maintenance of your Progress Lighting P3849-77WB 3-Light Directional Light. Please read all instructions carefully before beginning installation and retain this manual for future reference.
This fixture is designed for both wall and ceiling mount applications and features a durable forged bronze finish with etched glass shades.
Safety Information
WARNING: Risk of electric shock. Disconnect power at the fuse box or circuit breaker before installation or servicing.
- All electrical connections must be in accordance with local codes, ordinances, or the National Electric Code (NEC).
- Consult a qualified electrician if you are unfamiliar with electrical wiring.
- Use only the specified bulb type and wattage to avoid fire hazards.
- Do not install this fixture in areas where it may be exposed to direct water spray or submersion, unless specifically rated for such conditions. This fixture is damp location listed.
- Handle glass components with care to prevent breakage.
Package Contents
Verify that all components are present before discarding packaging materials.
- 1 x Progress Lighting P3849-77WB 3-Light Directional Light Fixture
- 3 x 50-Watt MR-16 (120V GU10) Bulbs
- Mounting Hardware (typically includes mounting strap, screws, wire nuts)
- Instruction Manual (this document)
Setup and Installation
Professional installation by a licensed electrician is recommended for safety and proper functionality.
- Prepare for Installation: Turn off power at the circuit breaker or fuse box. Ensure the power is off before proceeding.
- Mounting Bracket Installation: Secure the mounting bracket to the junction box using the provided screws. Ensure the bracket is firmly attached to support the fixture's weight.
- Electrical Connections: Connect the fixture's wires to the corresponding house wires. Typically, black to black (live), white to white (neutral), and bare copper or green to bare copper or green (ground). Use approved wire connectors and ensure all connections are secure.
- Fixture Mounting: Carefully attach the fixture body to the mounting bracket, securing it with the provided screws or nuts. Ensure the fixture is flush against the wall or ceiling.
- Bulb Installation: Insert the three 50-Watt MR-16 (GU10) bulbs into their respective sockets. Ensure they are seated correctly.
- Glass Shade Installation: Carefully attach the etched glass shades to the fixture. Follow any specific instructions for securing the shades to prevent them from falling.
- Restore Power: Once installation is complete and all components are secure, restore power at the circuit breaker or fuse box.

Image: The Progress Lighting P3849-77WB 3-Light Directional Light, showcasing its forged bronze finish and three etched glass shades.
Operating Instructions
The Progress Lighting P3849-77WB fixture operates via a standard wall switch connected to its electrical circuit. Simply toggle the wall switch to turn the light on or off.
This fixture is dimmable. If connected to a compatible dimmer switch (sold separately), you can adjust the light intensity to your preference. Ensure the dimmer switch is rated for LED or incandescent loads as appropriate for the bulbs used.
Maintenance
Regular maintenance ensures the longevity and appearance of your lighting fixture.
- Cleaning: To clean the fixture, ensure the power is off. Wipe the forged bronze finish with a soft, dry cloth. For the etched glass shades, use a mild glass cleaner on a soft cloth, avoiding abrasive materials that could scratch the surface.
- Bulb Replacement: Before replacing bulbs, turn off the power to the fixture. Allow bulbs to cool completely. Carefully remove the old bulb and insert a new 50-Watt MR-16 (GU10) bulb. Do not exceed the maximum wattage specified.
- Inspection: Periodically inspect the fixture for any loose wiring or damage. If any issues are found, disconnect power and consult a qualified electrician.
Troubleshooting
If you encounter issues with your fixture, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | No power to the fixture Loose wire connections Faulty bulb | Check circuit breaker/fuse Verify all wire connections are secure (power off) Replace bulb with a known good one |
| Light flickers | Loose bulb Incompatible dimmer switch Loose wire connection | Tighten bulb Ensure dimmer is compatible with bulb type Check wire connections (power off) |
| Dimming not working | Incompatible dimmer switch Bulbs not dimmable | Ensure dimmer is compatible with bulb type and fixture Verify bulbs are dimmable MR-16 (GU10) |
If these steps do not resolve the issue, consult a qualified electrician.
Specifications
- Model: P3849-77WB
- Brand: Progress Lighting
- Finish: Forged Bronze
- Shade Material: Etched Glass
- Number of Lights: 3
- Bulb Type: MR-16 (GU10)
- Max Wattage per Bulb: 50W (120V)
- Power Source: Corded Electric
- Special Feature: Dimmable
- Dimensions (Overall): 24-Inch Width x 9-Inch Height x 7-Inch Extension (approximately 61 cm W x 22.9 cm H x 17.8 cm D)
- Item Weight: Approximately 5 Pounds (2.27 kg)
- Location Rating: Damp Location Listed
Warranty Information
This Progress Lighting fixture is covered by a 1-Year Manufacturer's Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, or unauthorized repairs.
Customer Support
For technical assistance, warranty inquiries, or replacement parts, please contact Progress Lighting customer service. Refer to the official Progress Lighting website for current contact information.
Website: www.progresslighting.com