Kohler K-922-CP

KOHLER Laminar K-922-CP Wall- or Ceiling-Mount Bath Filler Instruction Manual

Model: K-922-CP

Introduction

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your KOHLER Laminar K-922-CP Wall- or Ceiling-Mount Bath Filler. Please read this manual thoroughly before beginning installation or use to ensure proper function and to prevent damage. Retain this manual for future reference.

Safety Information

WARNING: Risk of personal injury or product damage. Follow all instructions carefully.

  • Always turn off the main water supply before installing or servicing the bath filler.
  • Wear appropriate personal protective equipment (PPE) during installation, including safety glasses and gloves.
  • Ensure all plumbing connections are secure and leak-free to prevent water damage.
  • If you are unsure about any part of the installation process, consult a qualified plumber.
  • Do not use abrasive cleaners or harsh chemicals on the product finish, as this may cause damage and void the warranty.

Product Overview

The KOHLER Laminar K-922-CP bath filler is designed to deliver a visually striking, solid stream of water to your bath. It can be mounted on either a wall or ceiling, offering versatile installation options. Its pressure-compensating flow control ensures a smooth, splatter-free column of water.

Key Features:

  • Pressure-compensating flow control for a splatter-free water column.
  • 0.8" (20 mm) orifice for optimized performance.
  • Easy-to-access cartridge for simplified cleaning and replacement.
  • Solid brass construction for durability and reliability.
  • KOHLER finishes are designed to resist corrosion and tarnishing.
  • Versatile wall- or ceiling-mount installation.
  • Complements the KOHLER Purist collection.

Components:

  • Laminar wall- or ceiling-mount bath filler with 0.8" orifice.
  • Installation hardware (specific items may vary, refer to packaging).
KOHLER Laminar K-922-CP Bath Filler in Polished Chrome

Image: The KOHLER Laminar K-922-CP Wall- or Ceiling-Mount Bath Filler in Polished Chrome. This image shows the sleek design and polished finish of the bath filler.

Installation

Proper installation is crucial for the optimal performance and longevity of your bath filler. It is recommended that installation be performed by a qualified professional plumber.

Pre-Installation Considerations:

  • Water Supply: Ensure the main water supply to the installation area is turned off.
  • Piping: For optimal laminar flow effect, a 3/4 inch (19 mm) piping is recommended to ensure sufficient water pressure. While 1/2 inch piping may work, it might not provide the full desired effect.
  • Mounting Location: This bath filler can be installed either on a wall or ceiling. Plan the exact location carefully, considering the bath tub's position and desired water stream trajectory.
  • Drainage: When wall-mounted, some dripping may occur after shut-off. Ensure the wall surface is tiled or protected, and consider a suitable method to manage any residual water.
  • Insulation: If installing in a cold climate or an unheated space, ensure adequate insulation around the water supply lines to prevent freezing.

General Installation Steps (Consult detailed diagrams in the included physical manual):

  1. Prepare the mounting surface (wall or ceiling) according to local plumbing codes and product specifications.
  2. Install the rough-in valve and secure it firmly.
  3. Connect the hot and cold water supply lines to the rough-in valve.
  4. Attach the bath filler body to the rough-in valve, ensuring all connections are tight and sealed.
  5. Perform a leak test by slowly turning on the water supply and checking all connections.
  6. Secure any trim plates or escutcheons.

Note: Specific installation steps and required tools will be detailed in the physical installation guide provided with your product. Always refer to that guide for precise instructions.

Operation

The KOHLER Laminar bath filler is designed for straightforward operation, providing a consistent and visually appealing water flow.

  • To activate the water flow, use the separate control handles (not included with the filler itself, typically part of a mixing valve) to turn on the water supply.
  • The bath filler's internal pressure-compensating flow control will automatically regulate the water to produce a smooth, laminar stream with minimal splashing.
  • Adjust water temperature and flow rate using your bath's mixing valve controls.
  • To stop the water flow, turn off the water supply using the control handles.

Maintenance

Regular maintenance will help preserve the finish and functionality of your KOHLER bath filler.

Cleaning the Finish:

  • Clean the polished chrome finish with a soft, damp cloth.
  • Use mild soap and water if necessary, then rinse thoroughly and dry with a soft cloth to prevent water spots.
  • Avoid abrasive cleaners, scouring pads, or chemicals containing ammonia, bleach, or alcohol, as these can damage the finish.
  • KOHLER finishes are designed to resist corrosion and tarnishing, but proper cleaning practices are essential for long-term appearance.

Cartridge Access and Replacement:

  • The bath filler features an easy-to-access cartridge for cleaning or replacement.
  • If you experience reduced flow or inconsistent laminar stream, the cartridge may need cleaning or replacement.
  • Refer to the specific instructions provided with your product for detailed steps on accessing and servicing the cartridge.
  • Always turn off the water supply before attempting any cartridge maintenance.

Troubleshooting

If you encounter issues with your KOHLER Laminar bath filler, consult the following common troubleshooting tips:

ProblemPossible CauseSolution
Water flow is weak or not a solid laminar stream.
  • Insufficient water pressure from supply.
  • Piping size is too small (e.g., 1/2 inch instead of recommended 3/4 inch).
  • Cartridge is clogged or dirty.
  • Verify adequate water pressure to the fixture.
  • Ensure proper piping size was used during installation.
  • Clean or replace the cartridge (refer to Maintenance section).
Excessive splashing during operation.
  • Water pressure is too high.
  • Orifice is partially blocked.
  • Check water pressure and adjust if possible.
  • Inspect the 0.8" orifice for any obstructions and clean if necessary.
Water drips after shut-off (especially with wall-mount).
  • Normal residual drainage from the spout.
  • Improper installation or sealing.
  • This can be a characteristic of laminar fillers. Ensure proper drainage solutions are in place.
  • Re-check installation for proper sealing and ensure the product is level.
Leaking from connections.
  • Loose connections.
  • Damaged seals or O-rings.
  • Turn off water supply and carefully tighten all connections.
  • Inspect and replace any damaged seals or O-rings.

If problems persist after attempting these solutions, contact KOHLER customer service or a qualified plumber.

Specifications

FeatureDetail
BrandKohler
Model NameLaminar
Model NumberK-922-CP
Mounting TypeWall Mount, Ceiling Mount
Finish TypePolished Chrome
MaterialBrass
Orifice Diameter0.8" (20 mm)
Flow Rate5 Gallons Per Minute
Valve TypeCartridge Valve
Item Weight3.04 ounces
Item Dimensions (D x W x H)4"D x 6"W x 5"H
Spout Reach10 Centimeters
UPC087206539817

Warranty and Support

Warranty Information:

This KOHLER product is covered by the KOHLER Faucet Lifetime Limited Warranty. This warranty covers defects in material and workmanship for the original consumer purchaser. For full details regarding warranty coverage, limitations, and how to make a claim, please refer to the official warranty documentation included with your product or visit the official KOHLER website.

Customer Support:

For technical assistance, replacement parts, or any questions regarding your KOHLER Laminar K-922-CP bath filler, please contact KOHLER customer service. Contact information can typically be found on the official KOHLER website or in the packaging materials.

Website: www.kohler.com

Related Documents - K-922-CP

Preview Kohler Purist K-14381 Towel Shelf: Specifications, Features, and Finishes
Detailed specifications, features, dimensions, available finishes, and warranty information for the Kohler Purist K-14381 Towel Shelf. Includes installation notes and product overview.
Preview KOHLER Sunstruck® 65-1/2" Freestanding Heated BubbleMassage™ Air Bath (K-1967-GH) - Specifications
Detailed specifications and features for the KOHLER Sunstruck® K-1967-GH freestanding heated air bath, including dimensions, materials, technology, installation requirements, and warranty information.
Preview KOHLER Devonshire Rite-Temp Valve Trim K-TS397-4 Specification Sheet
Detailed specification sheet for the KOHLER Devonshire Rite-Temp Valve Trim (K-TS397-4), outlining its features, materials, installation requirements, codes, available finishes, and technical dimensions. Includes information on ADA compliance and warranty.
Preview KOHLER K-23294 Square 18-Inch Grab Bar - Technical Specifications & Features
Detailed specifications for the KOHLER K-23294 Square 18-inch grab bar, including features, material, dimensions, ADA compliance, available finishes, and installation notes. Built for durability and reliability.
Preview KOHLER Coralais Rite-Temp Valve Trim K-TS15621-4 Specification Sheet
Detailed specifications for the KOHLER Coralais Rite-Temp Valve Trim (Model K-TS15621-4). This document outlines features, material, installation requirements, compatible accessories, codes/standards, warranty information, and available finishes for this faucet trim.
Preview KOHLER Artifacts® Kitchen Sink Faucet with KOHLER® Konnect™ K-29709-WB - Features, Specifications, and Installation
Explore the KOHLER Artifacts® K-29709-WB kitchen sink faucet, featuring touchless activation, KOHLER® Konnect™ smart technology, three spray functions, and premium metal construction. Includes specifications, installation details, and available finishes.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.