Taco 008-F6

Taco 008-F6 Cast Iron Pump User Manual

Model: 008-F6

Product Overview

The Taco Model 008 Cartridge Circulator is engineered for a broad spectrum of residential and light commercial applications requiring higher head water circulation. Its design incorporates a unique, replaceable cartridge that houses all moving parts, simplifying maintenance and eliminating the need to replace the entire unit. This compact, direct-drive circulator features low power consumption, making it an efficient choice for various systems.

Taco 008-F6 Cast Iron Pump with two black O-rings

Figure 1: Taco 008-F6 Cast Iron Pump. This image shows the green cast iron pump unit with its motor housing and flange connections. Two black O-rings are visible in the foreground, likely for sealing connections.

Key Features

Setup and Installation

Proper installation is crucial for the optimal performance and longevity of your Taco 008-F6 pump. Always ensure the power supply is disconnected before beginning any installation work.

Pre-Installation Checklist:

Installation Steps:

  1. System Preparation: Drain the system completely and ensure all valves are closed to prevent water flow during installation.
  2. Mounting: Position the pump in the desired location, ensuring it is securely mounted to a stable surface. The universal flange-to-flange dimensions facilitate direct replacement in many existing systems.
  3. Plumbing Connections: Connect the pump to the system piping using appropriate fittings. Ensure all connections are tight and leak-free. Use the provided O-rings for a proper seal.
  4. Electrical Wiring: Connect the pump to the electrical supply according to local codes and the pump's wiring diagram. The pump operates on 115V AC/DC power. Ensure proper grounding.
  5. System Refill: Once plumbing and electrical connections are complete, slowly refill the system, bleeding air as necessary to prevent airlocks.
  6. Final Check: Double-check all connections for leaks and ensure the pump is properly wired before restoring power.

Note: For detailed wiring diagrams and specific plumbing configurations, refer to the separate installation guide provided with the product packaging.

Operating Instructions

The Taco 008-F6 pump is designed for straightforward operation once properly installed.

Starting the Pump:

  1. Ensure the system is fully filled with fluid and all air has been purged.
  2. Restore electrical power to the pump. The pump should begin operating quietly.
  3. Monitor the system for the first few minutes of operation to ensure proper flow and no unusual noises or leaks.

Normal Operation:

The 008-F6 circulator is designed for continuous, quiet operation. It is self-lubricating and requires no external lubrication. The pump will circulate water within your system as required by your thermostat or control system.

Shutting Down the Pump:

To shut down the pump, simply disconnect the electrical power supply. For extended periods of non-use, it is recommended to drain the system to prevent freezing or stagnation, especially in unheated areas.

Maintenance

The Taco 008-F6 circulator is designed for minimal maintenance due to its self-lubricating and cartridge-based design. However, periodic checks can help ensure its long-term reliability.

Routine Checks:

Cartridge Replacement:

One of the key features of the 008-F6 is its replaceable cartridge, which contains all the moving parts. If the pump experiences issues related to the motor or impeller, the cartridge can be replaced without replacing the entire pump body.

  1. Disconnect Power: Always disconnect electrical power to the pump before attempting any service.
  2. Isolate and Drain: Close isolation valves on either side of the pump and drain the section of the system containing the pump.
  3. Remove Fasteners: Loosen and remove the bolts securing the motor housing to the pump volute.
  4. Extract Cartridge: Carefully pull the motor and cartridge assembly away from the pump body. The cartridge will come out with the motor.
  5. Install New Cartridge: Install a new, genuine Taco replacement cartridge onto the motor shaft.
  6. Reassemble: Reinsert the motor and new cartridge assembly into the pump volute, ensuring the O-ring is properly seated. Tighten the fasteners evenly.
  7. Refill and Test: Refill the system, bleed air, and restore power to test the pump.

Consult a qualified technician if you are unsure about any maintenance procedures.

Troubleshooting

This section provides solutions to common issues you might encounter with your Taco 008-F6 pump. Always disconnect power before performing any inspection or repair.

ProblemPossible CauseSolution
Pump does not start
  • No electrical power
  • Motor seized
  • Wiring error
  • Check power supply and circuit breaker.
  • Attempt to free the impeller (if accessible and safe). Consider cartridge replacement.
  • Verify wiring against diagram.
Pump runs but no flow
  • Airlock in system
  • Closed valves
  • Impeller obstruction
  • Bleed air from the system.
  • Open all necessary isolation valves.
  • Inspect and clear any obstructions in the impeller area (after disconnecting power).
Noisy operation
  • Air in system
  • Worn bearings (cartridge)
  • Cavitation
  • Bleed air from the system.
  • Replace the cartridge assembly.
  • Ensure adequate system pressure and flow.
Leaking at connections
  • Loose fittings
  • Damaged O-rings/gaskets
  • Tighten connections.
  • Replace O-rings or gaskets.

If the problem persists after attempting these solutions, contact a qualified plumbing or HVAC professional.

Specifications

AttributeDetail
ManufacturerTaco
Model Number008-F6
Part Number008-F6
Item Weight7 pounds
Product Dimensions8 x 6 x 6 inches
MaterialCast Iron
Power SourceAC/DC
Voltage115V
Horsepower0.025 (1/40) HP
Max Water Temperature110°C (230°F)
Included ComponentsTaco 008-F6 Cast Iron Cartridge Circulator - 008 Series, 115 V

Support Information

For further assistance, technical support, or to inquire about replacement parts, please contact Taco directly. While specific contact details are not provided in this manual, you can typically find up-to-date information on the official Taco website or through authorized distributors.

When contacting support, please have your pump's model number (008-F6) and any relevant purchase information ready.

Related Documents - 008-F6

Preview Taco 1911ecm ECM High-Efficiency Circulator Instruction Sheet
Instruction sheet for the Taco 1911ecm ECM High-Efficiency Circulator, covering installation, operation, controller functions, specifications, and troubleshooting. Learn about its features, safety guidelines, and maintenance.
Preview Taco SR501-4 Switching Relay Instruction Sheet and Wiring Guide
Detailed instruction sheet for the Taco SR501-4 Switching Relay, covering features, operation, wiring diagrams, specifications, troubleshooting, and warranty information for HVAC professionals.
Preview Taco 0026e ECM High-Efficiency Circulator Instruction Sheet
Instruction sheet for the Taco 0026e ECM High-Efficiency Circulator, detailing its features, applications, installation, wiring, programming, and troubleshooting. This variable speed circulator offers significant energy savings and replaces older single and 3-speed models.
Preview Taco Domestic Hot Water Recirculation Systems: Application, Selection & Installation Guide
A comprehensive guide to Taco's Domestic Hot Water Recirculation (DHWR) systems, detailing their application, selection process, and installation. Learn how to achieve instant hot water, conserve water and energy, and choose the right Taco product for residential use.
Preview Taco SR506 Switching Relay Instruction Sheet
Instruction sheet for the Taco SR506 Switching Relay, detailing wiring diagrams, operation, priority settings, jumper placement, power input, external diagnostics, and specifications for both Cold Start Boiler and Tankless Coil Boiler applications. Includes features and manufacturer information.
Preview Taco Hot-LinkPlus-e: High-Efficiency Hot Water Recirculation System | Installation & Specs
Learn about the Taco Hot-LinkPlus-e system, an ECM high-efficiency hot water recirculation system. Features include instant hot water, water savings, SmartPlug control, and easy installation without a dedicated return line. Includes technical specifications and installation guide.