This manual provides essential information for the installation, operation, and maintenance of your SANIFLO Sanigrind Pro Grinder Pump. The Sanigrind Pro is designed for managing black and gray water from complete bathroom and laundry installations, suitable for both residential and commercial use. Please read these instructions thoroughly before installation and use to ensure proper function and safety.
2. Safety Information
Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury. This device operates with electricity and handles wastewater. Improper installation or maintenance can lead to hazards.
- Ensure the power supply is disconnected before performing any maintenance or service.
- All electrical connections must comply with local codes and be performed by a qualified electrician.
- Do not operate the pump if it has been damaged or submerged in water.
- Do not flush foreign objects such as plastics, metals, or excessive amounts of sanitary products, as this can damage the grinder mechanism.
- Wear appropriate personal protective equipment (PPE) when handling wastewater or performing maintenance.
3. Product Overview
The SANIFLO Sanigrind Pro is a heavy-duty grinder pump featuring a 1 HP motor and stainless steel blades. It is designed to efficiently handle wastewater from various fixtures, including toilets, sinks, showers, bathtubs, laundry sinks, and washing machines.
3.1 Key Components
- Grinder Mechanism: 1 HP motor with stainless steel blades for macerating waste.
- Pump: Discharges wastewater vertically up to 25 feet and horizontally up to 150 feet.
- Inlets: Low inlets for flexible connection to various plumbing fixtures.
- Service Panel: Easy-access panel for simplified maintenance without disconnecting plumbing.
- Non-Return Valve: Integrated into the discharge elbow assembly to prevent backflow.
- Vent Connection: 1-1/2 inch vent connection on top of the lid, required for all plumbing codes.

Figure 3.1: Exploded view of the Sanigrind Pro, showing internal and external components.

Figure 3.2: Numbered diagram highlighting key features and connections of the Sanigrind Pro.

Figure 3.3: Illustration of various plumbing fixtures that can be connected to the Sanigrind Pro, including toilets, sinks, showers, bathtubs, laundry sinks, and washing machines, for both residential and commercial applications.
4. Setup and Installation
The Sanigrind Pro is designed for floor installation and can be used to create a complete bathroom or laundry facility up to 25 feet below the sewer line or up to 150 feet away from a soil stack. Professional installation is recommended.
4.1 Placement
- Place the unit on a firm, level surface.
- Ensure adequate space around the unit for ventilation and future maintenance access.
- The unit should be positioned to allow for proper gravity flow from connected fixtures where applicable.
4.2 Plumbing Connections
- Connect the toilet outlet to the main inlet of the Sanigrind Pro. The unit is designed for conventional toilets with a bottom outlet (toilet not supplied by Saniflo).
- Connect additional fixtures (sink, shower, bathtub, washing machine) to the 2-inch side inlets. These inlets include built-in check valves.
- Install the discharge pipe (3/4 inch or 1 inch rigid pipe) from the pump's outlet. Ensure the non-return valve is correctly installed in the discharge elbow assembly.
- Connect the 1-1/2 inch vent to a proper vent system as required by local plumbing codes.

Figure 4.1: Example installation of the Sanigrind Pro in a bathroom, demonstrating its ability to pump wastewater below sewer lines or over distances.

Figure 4.2: Detailed view of the Sanigrind Pro's plumbing connections during installation.
4.3 Electrical Connection
- The unit requires a 120 Volt, 60 Hz electrical supply.
- Connect the pump to a dedicated, properly grounded electrical circuit protected by a Ground Fault Circuit Interrupter (GFCI).
- All electrical work must be performed by a licensed electrician and conform to all local and national electrical codes.
5. Operating Instructions
Once properly installed and connected, the Sanigrind Pro operates automatically. When wastewater enters the unit, a pressure switch activates the motor, which grinds the waste and pumps it through the discharge pipe.
- Ensure the unit is plugged into a live, GFCI-protected outlet.
- The pump will activate automatically when water levels rise within the unit.
- After discharge, the pump will automatically shut off.
- Avoid flushing items that are not biodegradable or can cause blockages, such as wipes, paper towels, feminine hygiene products, or excessive amounts of toilet paper.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your Sanigrind Pro. Always disconnect power before performing any maintenance.
6.1 Routine Cleaning
- Periodically clean the exterior of the unit with a damp cloth.
- For internal cleaning and descaling, use a specialized descaler product designed for macerating units. Follow the descaler manufacturer's instructions.
- Do not use harsh chemicals, solvents, or abrasive cleaners, as these can damage the unit.
6.2 Accessing the Service Panel
The Sanigrind Pro features an easy-access service panel on top, allowing for maintenance of electrical components without disconnecting existing plumbing. Refer to the technical diagram (Figure 3.2) for the location of the service panel.
- Disconnect power to the unit.
- Carefully remove the service panel cover.
- Perform necessary inspections or repairs. If you are not qualified, contact a professional technician.
- Ensure the service panel is securely re-sealed after maintenance to prevent leaks.
7. Troubleshooting
This section addresses common issues you might encounter with your Sanigrind Pro. For problems not listed here, or if solutions do not resolve the issue, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; clogged inlet; motor fault. | Check power supply and GFCI. Inspect inlets for blockages. If motor fault, contact support. |
| Pump runs continuously | Pressure switch fault; continuous water inflow; discharge pipe blockage. | Check for leaks from connected fixtures. Inspect discharge pipe for obstructions. Contact support for pressure switch issues. |
| Pump is noisy or vibrates excessively | Foreign object in grinder; worn motor bearings; improper installation. | Disconnect power and inspect grinder for foreign objects (use caution). Ensure unit is securely installed. Contact support if noise persists. |
| Water leaks from unit | Loose connections; damaged seals; cracked housing. | Check all plumbing connections for tightness. Inspect seals and housing for damage. Contact support for replacement parts or service. |
| Slow discharge or weak flow | Partial blockage in discharge pipe; pump impeller issue; excessive vertical lift. | Inspect discharge pipe for partial blockages. Ensure installation parameters (lift/distance) are within specifications. Contact support if issue persists. |
8. Specifications
The following are the technical specifications for the SANIFLO Sanigrind Pro Grinder Pump (Model 014).

Figure 8.1: Technical specifications, pump curve, and dimensional drawings for the Sanigrind Pro.
| Feature | Detail |
|---|---|
| Model | 014 |
| Power Source | Corded Electric |
| Voltage | 120 Volts |
| Frequency | 60 Hz |
| Motor | 1 HP oil-filled thermally protected motor |
| Maximum Flow Rate | 19 Gallons Per Minute |
| Maximum Lifting Height | 25 Feet |
| Maximum Horizontal Discharge | 150 Feet |
| Discharge Pipe Diameter | 3/4" or 1" |
| Inlets | 2" (sides), 1-1/2" (top) |
| Vent Connection | 1-1/2" |
| Operating Temperature | Up to 104°F (40°C) |
| Noise Level | Less than 65 dBA (measured at 3 ft.) |
| Item Weight | 30 Pounds (13.6 kg) |
| Product Dimensions | 8 x 20.31 x 13 inches |
| Material | Plastic |
| Certifications | CSA (IPC, NSPC), IAPMO (UPC) |
9. Warranty Information
The SANIFLO Sanigrind Pro Grinder Pump comes with a 3-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims. The warranty does not cover damage resulting from improper installation, misuse, neglect, unauthorized repairs, or flushing of prohibited items.
10. Customer Support
For technical assistance, troubleshooting guidance, or warranty claims, please contact SANIFLO customer support. SANIFLO offers local U.S. support and phone assistance. Our trained professionals are available to help ensure reliable service for your Sanigrind Pro.
Please visit the official SANIFLO website or refer to your product packaging for the most current contact information.