1. Introduction
The Mastech MS8229 is an advanced 5-in-1 multi-functional digital multimeter designed for a wide range of electrical and environmental measurements. This device integrates the functions of a digital multimeter, sound level meter, thermometer, luxmeter, and humidity meter into a single, compact unit. It features an auto-ranging capability, a backlit LCD screen, and intelligent safety warnings for test lead connections.
This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your MS8229 multimeter. Please read this manual thoroughly before using the device.
2. Safety Information
Always adhere to the following safety precautions to prevent personal injury or damage to the multimeter or equipment under test.
- Do not exceed the maximum input limits for any function.
- Do not use the meter if it or the test leads appear damaged.
- Always ensure the function switch is in the correct position for the measurement being performed.
- Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Disconnect the test leads from the circuit before changing functions.
- Remove the test leads from the meter before opening the battery cover.
- Use caution when making measurements on circuits with high current or voltage.
- Do not operate the meter in explosive gas, vapor, or dust environments.
- Ensure the battery compartment is securely closed before operation.
3. Product Overview
The Mastech MS8229 combines multiple measurement capabilities in one robust device. Key components include:
- LCD Display: Large, backlit screen for clear readings.
- Function Switch: Rotary dial to select desired measurement mode.
- Input Jacks: Clearly labeled ports for test lead connection, with LED/sound warnings for incorrect connections.
- Function Buttons: Buttons for specific features like RANGE, SELECT, REL (Relative), HOLD/B.L (Hold/Backlight), and C/F (Celsius/Fahrenheit).
- Environmental Sensors: Integrated sensors for light (Lux), sound (dB), and humidity (RH).
- Kickstand: Integrated stand for hands-free operation.

Figure 3.1: Front view of the Mastech MS8229 Digital Multimeter with connected test leads. The image shows the main display, rotary function switch, various buttons, and input jacks.
4. Setup
4.1 Battery Installation
The MS8229 requires three (3) AAA 1.5V batteries for operation. Batteries are not included with the unit.
- Ensure the multimeter is turned OFF.
- Locate the battery compartment on the rear of the unit.
- Using a Phillips head screwdriver, loosen the two screws securing the battery cover.
- Carefully remove the battery cover.
- Insert three AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Replace the battery cover and tighten the screws securely.
4.2 Connecting Test Leads
The multimeter comes with a pair of test leads (red and black). Always connect them correctly for accurate and safe measurements.
- Connect the black test lead to the COM (Common) input jack.
- Connect the red test lead to the appropriate input jack based on the desired measurement:
- For Voltage (V), Resistance (Ω), Capacitance (F), Frequency (Hz), Diode Test, Continuity, Temperature (TEMP), Lux, Humidity, and Sound (dB), connect the red lead to the VΩHz input jack.
- For milliampere (mA) or microampere (µA) current measurements, connect the red lead to the mA/µA input jack.
- For 10 Ampere (10A) current measurements, connect the red lead to the 10A input jack.
- The meter features an LED/sound warning system that illuminates the correct input jacks and sounds an alarm if the leads are connected incorrectly for the selected function.
5. Operating Instructions
This section details how to use the various functions of the MS8229 multimeter.
5.1 Basic Multimeter Functions (Voltage, Current, Resistance, Capacitance, Frequency, Diode, Continuity)
- Voltage Measurement (DCV/ACV):
- Turn the function switch to the V∼ (AC Voltage) or V— (DC Voltage) position.
- Connect the test leads to the circuit in parallel.
- The meter will automatically select the range. Press SELECT to toggle between AC and DC voltage if needed.
- Current Measurement (DCA/ACA):
- Turn the function switch to the A∼ (AC Current) or A— (DC Current) position, or mA/µA.
- Connect the test leads in series with the circuit.
- Ensure the red test lead is in the correct current input jack (mA/µA or 10A).
- Press SELECT to toggle between AC and DC current if needed.
- Resistance Measurement (Ω):
- Turn the function switch to the Ω position.
- Ensure the circuit is de-energized before measuring resistance.
- Connect the test leads across the component.
- Capacitance Measurement (F):
- Turn the function switch to the Ω position, then press SELECT until "F" (Farad) is displayed.
- Ensure the capacitor is fully discharged before measurement.
- Connect the test leads across the capacitor terminals.
- Frequency (Hz) and Duty Cycle (%):
- Turn the function switch to the Hz/% position.
- Connect the test leads to the signal source.
- Press SELECT to toggle between Frequency and Duty Cycle display.
- Diode Test:
- Turn the function switch to the Ω position, then press SELECT until the diode symbol is displayed.
- Connect the red lead to the anode and the black lead to the cathode for forward bias reading. Reverse for reverse bias.
- Continuity Test:
- Turn the function switch to the Ω position, then press SELECT until the continuity symbol (buzzer) is displayed.
- Connect the test leads across the circuit or component. A continuous beep indicates continuity (resistance less than 40 ohms).
5.2 Environmental Measurement Functions
The MS8229 offers integrated sensors for environmental parameters.
- Temperature Measurement (℃/℉):
- Turn the function switch to the TEMP position.
- The meter will display the ambient temperature using its internal sensor.
- For external temperature measurement, connect the K-Type thermocouple probe (supplied) to the TEMP µA/mA and COM input jacks.
- Press the C/F button to switch between Celsius and Fahrenheit.
- Humidity Measurement (RH):
- Turn the function switch to the RH position.
- The meter will display the relative humidity percentage.
- Lux Measurement (Lux):
- Turn the function switch to the Lux position.
- Point the top of the meter towards the light source. The display will show the illuminance in Lux.
- Sound Level Measurement (dB):
- Turn the function switch to the dB position.
- The meter will display the sound pressure level in decibels (dB).
5.3 Additional Features
- HOLD/B.L Button: Press briefly to hold the current reading on the display. Press and hold for 2 seconds to activate/deactivate the backlight.
- RANGE Button: In auto-ranging modes, press to switch to manual ranging. Press again to cycle through ranges. Press and hold to return to auto-ranging.
- REL (Relative) Button: Used to measure a value relative to a stored reference value. Press to store the current reading as a reference, subsequent readings will be displayed as the difference from this reference. Press again to exit relative mode.
6. Maintenance
6.1 Cleaning
To maintain the accuracy and longevity of your multimeter:
- Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Keep the input jacks and rotary switch clean and free of dust.
6.2 Battery Replacement
Replace the batteries when the low battery indicator appears on the display. Refer to Section 4.1 for battery installation instructions.
6.3 Fuse Replacement
The MS8229 is protected by internal fuses. If the current measurement function fails, the fuse may need replacement. Fuse replacement should only be performed by qualified personnel.
- Ensure the meter is OFF and test leads are disconnected.
- Open the battery compartment (refer to Section 4.1).
- Locate the fuse(s) inside. Replace with fuses of the exact same type and rating. (e.g., 400mA/250V fast-blow for mA/µA range, 10A/250V fast-blow for 10A range).
- Securely close the battery compartment.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not power on. | Dead or incorrectly installed batteries. | Check battery polarity, replace batteries. |
| No reading or "OL" (Overload) displayed. | Incorrect function selected, open circuit, or measurement exceeds range. | Select correct function, check circuit continuity, ensure measurement is within meter's range. |
| Inaccurate readings. | Low battery, dirty test leads/jacks, external interference. | Replace batteries, clean leads/jacks, move away from strong electromagnetic fields. |
| Current measurement not working. | Blown fuse, incorrect lead connection. | Check/replace fuse (Section 6.3), ensure leads are in correct current jacks. |
| Backlight not working. | Backlight function not activated. | Press and hold the HOLD/B.L button for 2 seconds. |
8. Specifications
Detailed technical specifications for the Mastech MS8229.
| Parameter | Range / Accuracy |
|---|---|
| DC Voltage (DCV) | 400m/4/40/400/1000V, ± 0.7% |
| AC Voltage (ACV) | 400m/4/40/400V ± 0.8%, 750V ± 1.0% |
| DC Current (DCA) | 400µ/4m/40m/400m A ± 1.2%, 4/10A ± 2.0% |
| AC Current (ACA) | 400µ/4m/40m/400m A ± 1.5%, 4/10A ± 3.0% |
| Resistance (Ω) | 400/4K/40K/400K/4M ± 1.2%, 40M ± 2.0% |
| Capacitance (F) | 40n/400n/4m/40m/100mF ± 3.0% |
| Frequency (Hz) | 10/100/1K/10K/100KHz/200KHz ± 2.0%, >200KHz (reference only) |
| Temperature (℃/℉) | -20 to 1000 ℃ (0 to 1800 ℉) ± 3.0% (C/F selectable) |
| Relative Humidity (RH) | 20% to 95%, ± 5.0% |
| Lux (Illuminance) | 4,000/40,000 Lux, ± 5.0% |
| Sound Level (dB) | 40 to 100dB, ± 3.5% @ 94dB |
| Diode Test | Yes |
| Continuity Test | Buzzer if resistance < 40 Ω |
| Duty Cycle | 0.1% to 99.9% ± 3.0% |
| Dimensions | 195 x 92 x 55mm (7.68 x 3.62 x 2.17 inches) |
| Weight | 400g (0.88 lbs) |
| Battery | 3 x 1.5V AAA |
| Accessories | Test leads, K-Type thermo probe, User Manual |

Figure 8.1: Dimensions of the Mastech MS8229 Digital Multimeter, showing a height of 8.5 inches (21 cm).
9. Warranty and Support
For warranty information and technical support, please contact Mastech customer service. Details are typically provided on the product packaging or through the official Mastech website.
Manufacturer: Mastech
Model: MS8229
For further assistance, please refer to the official Mastech support channels.