ES 685 400 Amps DC/AC Current Probe/DMM with Frequency User Manual

Model: 685

1. Introduction

This manual provides comprehensive instructions for the safe and effective operation of your ES 685 400 Amps DC/AC Current Probe/DMM with Frequency. This device is a versatile tool designed for measuring DC and AC current, voltage, resistance, frequency, and continuity. Please read this manual thoroughly before use and retain it for future reference.

ES 685 Current Probe Digital Multimeter

Figure 1: ES 685 Current Probe Digital Multimeter. This image displays the main unit of the multimeter, featuring the clamp jaw, rotary dial, LCD screen, and function buttons.

2. Safety Information

Always observe safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the meter.

3. Product Overview

The ES 685 is a compact and robust current probe digital multimeter. It includes the main meter unit, test leads, a 9V battery, and a carrying case.

3.1 Components

ES 685 Multimeter with Test Leads and Battery

Figure 2: ES 685 Multimeter with included accessories. This image shows the multimeter unit alongside its red and black test leads and a 9V battery, illustrating the complete package.

ES 685 Multimeter Carrying Case

Figure 3: ES 685 Multimeter carrying case. This image displays the black zippered carrying case designed to protect and transport the multimeter and its accessories.

4. Setup

4.1 Battery Installation

  1. Ensure the meter is turned OFF.
  2. Remove the protective rubber holster from the meter.
  3. Locate the battery compartment cover on the back of the meter.
  4. Unscrew the retaining screw(s) and remove the cover.
  5. Connect a 9V battery (included) to the battery connector, observing correct polarity.
  6. Place the battery into the compartment and replace the cover, securing it with the screw(s).
  7. Reinstall the protective rubber holster.

4.2 Initial Check

After battery installation, turn the rotary switch to any function. The LCD display should illuminate and show a reading. If not, check battery installation or replace the battery.

5. Operating Instructions

The ES 685 features auto-ranging for most functions, simplifying operation. It offers 10 test functions and 35 test ranges.

5.1 DC/AC Current Measurement (Amps)

  1. Turn the rotary switch to the desired DC A or AC A range (e.g., 200A, 400A).
  2. For DC current, press the ZERO button to clear any offset before clamping.
  3. Open the clamp jaw and enclose only one conductor of the circuit. Ensure the jaw is fully closed.
  4. Read the current value on the LCD display.

5.2 Voltage Measurement (Volts)

  1. Insert the red test lead into the VΩHz jack and the black test lead into the COM jack.
  2. Turn the rotary switch to the desired DC V or AC V range.
  3. Connect the test leads in parallel to the circuit or component to be measured.
  4. Read the voltage value on the LCD display.

5.3 Resistance Measurement (Ohms)

  1. Ensure the circuit is de-energized before measuring resistance.
  2. Insert the red test lead into the VΩHz jack and the black test lead into the COM jack.
  3. Turn the rotary switch to the Ω (Ohms) range.
  4. Connect the test leads across the component to be measured.
  5. Read the resistance value on the LCD display.

5.4 Frequency and Duty Cycle Measurement (Hz/%)

  1. Insert the red test lead into the VΩHz jack and the black test lead into the COM jack.
  2. Turn the rotary switch to the Hz/% range.
  3. Connect the test leads across the signal source.
  4. The display will show the frequency in Hz. Press the Hz/% button to toggle to duty cycle measurement.

5.5 Continuity Test

  1. Ensure the circuit is de-energized before testing continuity.
  2. Insert the red test lead into the VΩHz jack and the black test lead into the COM jack.
  3. Turn the rotary switch to the continuity (beep) range.
  4. Connect the test leads across the component or wire.
  5. If continuity exists (low resistance), the meter will emit an audible beep.

5.6 Data Hold Function

5.7 Auto Power Off

The meter is equipped with an auto power-off feature to conserve battery life. It will automatically turn off after a period of inactivity. To reactivate, turn the rotary switch to OFF and then back to the desired function.

6. Maintenance

6.1 Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.

6.2 Battery Replacement

When the battery indicator appears on the LCD, replace the 9V battery as described in Section 4.1.

7. Troubleshooting

8. Specifications

FeatureDetail
BrandES
Model685
Measurement TypeMultimeter (DC/AC Current, Voltage, Resistance, Frequency, Continuity)
Max Current (DC/AC)400 Amps
Clamp Opening7/8 inches
Test Functions10
Test Ranges35
Power Source9V Battery (included)
Auto-RangingYes
Auto Power OffYes
Data HoldYes
Item Weight1.1 Pounds (approx. 0.5 kg)
Product Dimensions (L x W x H)6.2 x 9.2 x 2.6 inches (approx. 15.7 x 23.4 x 6.6 cm)
UPC855174001045, 855174000000, 069060129489

9. Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact ES customer service. Keep your proof of purchase for warranty claims.