Schneider Electric HOM120CP

Download PDF
Contents

Schneider Electric Homeline 20 Amp Single Pole Circuit Breaker (HOM120CP) Instruction Manual

Introduction

This manual provides essential information for the safe and effective use of the Square D Homeline 20 Amp Circuit Breaker (Model HOM120CP). This device is designed to offer reliable residential circuit protection, safeguarding against overloads and short circuits. It is intended for installation in Square D Homeline load centers and CSEDs. Please read all instructions carefully before installation and operation.

Product Overview

The Square D Homeline 20 Amp Circuit Breaker is a single-pole device designed for 120/240V AC circuits. It features a plug-on neutral design for simplified installation.

Technical Benefits

Diagram illustrating technical benefits of the Square D Homeline 20 Amp Circuit Breaker, including 20A rating, overload and short-circuit protection, UL certification, 10kA breaking capacity, residential/commercial use, and compatibility with Homeline panels.

Image: Technical benefits of the Square D Homeline 20 Amp Circuit Breaker. This image highlights key features such as its 20A rating, protection against overloads and short-circuits, UL listing, 10kA breaking capacity, suitability for residential/commercial use, and compatibility with Homeline electrical panels and CSEDs.

Product Dimensions

Diagram showing the dimensions of the Square D Homeline 20 Amp Circuit Breaker: 3.13 inches height, 1 inch width, and 2.98 inches depth.

Image: Dimensions of the Square D Homeline 20 Amp Circuit Breaker. The breaker measures 3.13 inches in height, 1 inch in width, and 2.98 inches in depth, indicating its compact, single-space design.

Key Features

  • Residential Circuit Protection: Engineered for fast installation and superior circuit protection against overloads and short circuits.
  • Easy Installation: Features a plug-on neutral design with a shorter footprint for quick plug-in mounting in Square D Homeline load centers and CSEDs, occupying one space.
  • 20 Amp One-Pole: Designed for single 120/240V AC circuits, commonly used for wall receptacles, lighting fixtures, dishwashers, and disposals.
  • Standard Protection: Provides individual switching and tripping action. HACR rated.
  • High Breaking Capacity: Rated for 10kA breaking capacity.
  • UL-Listed: Certified for safety and reliability.

Setup and Installation

WARNING: Electrical work can be dangerous. Always ensure power is OFF at the main service panel before attempting any installation or maintenance. If you are not comfortable or experienced with electrical installations, consult a qualified electrician.

Understanding Your Circuit Breaker

Familiarize yourself with the physical characteristics and connection points of the circuit breaker.

Video: This video provides a close-up view of the Square D Homeline 20 Amp Single Pole Breaker, highlighting its design and connection terminals. It demonstrates the breaker's physical features and how it connects to the bus bar and wiring.

Compatibility and Safety Considerations

Ensure the breaker is compatible with your existing electrical panel and that the wire gauge matches the breaker's amperage rating.

Video: This video offers important information to consider before purchasing and installing a 20 Amp Homeline breaker. It covers compatibility with electrical panels, the importance of matching wire gauge to amperage, and general safety advice for electrical work.

Video: This video provides further details on what to know before buying a 20A HOM Breaker, reinforcing key aspects of compatibility and proper application within an electrical system.

Installation Steps

  1. Turn Off Power: Locate the main service panel and turn off the main breaker to completely de-energize the panel. Verify with a voltage tester.
  2. Remove Panel Cover: Carefully remove the cover of the electrical panel.
  3. Identify Slot: Choose an available slot in your Square D Homeline load center or CSED.
  4. Connect Neutral Wire (if applicable): For plug-on neutral designs, ensure the neutral wire is properly connected to the neutral bar.
  5. Install Breaker: Align the circuit breaker with the bus bar and firmly push it into place until it snaps securely.
  6. Connect Circuit Wire: Strip approximately 1/2 inch of insulation from the circuit wire. Insert the bare end of the circuit wire into the terminal screw on the breaker and tighten the screw firmly.
  7. Replace Panel Cover: Once all connections are secure and verified, replace the panel cover.
  8. Restore Power: Turn the main breaker back ON.

Operation

Turning the Breaker ON/OFF

  • To turn a circuit ON, push the breaker handle firmly to the 'ON' position.
  • To turn a circuit OFF, push the breaker handle firmly to the 'OFF' position.

Understanding a Tripped Breaker

If an overload or short circuit occurs, the breaker will automatically trip to the center position (between 'ON' and 'OFF'). To reset a tripped breaker:

  1. First, push the handle completely to the 'OFF' position.
  2. Then, push the handle firmly to the 'ON' position.
  3. If the breaker immediately trips again, there may still be an issue with the circuit. Consult a qualified electrician.

Maintenance

Circuit breakers generally require minimal maintenance. However, periodic checks are recommended:

  • Visual Inspection: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections.
  • Dust Removal: Ensure the area around the circuit breakers within the panel is clean and free of dust or debris.
  • Professional Check: Consider having a qualified electrician inspect your electrical panel and circuit breakers every few years to ensure optimal performance and safety.

Troubleshooting

If you encounter issues with your circuit breaker, consider the following:

  • Breaker Trips Repeatedly: If a breaker trips immediately after being reset, it indicates a persistent overload or short circuit. Disconnect all devices from the affected circuit and try resetting it again. If it still trips, there is an electrical fault that requires professional attention.
  • No Power to Circuit: If a breaker is in the 'ON' position but there is no power to the circuit, check if the main breaker is ON. If the issue persists, there might be a wiring problem or a faulty breaker.
  • Overheating: If you notice any unusual heat, burning smell, or buzzing sound from the electrical panel, immediately turn off the main power and contact a qualified electrician.

Specifications

SpecificationDetail
BrandSchneider Electric
Model NumberHOM120CP
Current Rating20 Amps
Number of Poles1
Voltage120/240V AC
Breaking Capacity10kA
Circuit Breaker TypeStandard, Thermal-Magnetic
Mounting TypePlug-In Mount
Product Dimensions (H x W x D)3.13" x 1" x 2.98" (79.50 mm x 25.44 mm x 75.69 mm)
Item Weight4.2 ounces
CertificationsUL-listed, HACR-rated
UPC047569062711

Warranty and Support

This Square D by Schneider Electric product is covered by the manufacturer's standard warranty. For specific warranty details, claims, or technical support, please refer to the official Schneider Electric website or contact their customer service directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Square D by Schneider Electric

© 2024 Schneider Electric. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.