Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your HERA SlimLite XL 34 7/8" Fluorescent Fixture. Please read this manual thoroughly before installation and retain it for future reference.

Figure 1: HERA SlimLite XL Fluorescent Fixture. This image displays the long, slender lighting unit, featuring a clear, ribbed cover over the fluorescent tube and a white base. One end of the fixture shows the electrical pins designed for connection.
Safety Information
Always observe the following safety precautions to reduce the risk of fire, electric shock, or injury to persons:
- Disconnect power before installing, servicing, or cleaning the fixture.
- Ensure the fixture is installed by a qualified electrician in accordance with all local and national electrical codes.
- Do not operate the fixture with a damaged cord or plug.
- Do not install in wet or damp locations unless specifically rated for such environments.
- Use only the specified lamp type and wattage as indicated on the fixture.
- Keep flammable materials away from the fixture during operation.
Package Contents
Verify that all components are present before beginning installation:
- HERA SlimLite XL Fluorescent Fixture (1 unit)
- Mounting hardware (screws, clips - may vary by package)
- Instruction Manual (this document)
Setup and Installation
The HERA SlimLite XL fixture features a convenient snap-in system for easy installation. Follow these steps:
- Preparation:
- Ensure power to the installation area is turned OFF at the circuit breaker.
- Identify the desired mounting location. The fixture is designed for under-cabinet or similar surface mounting.
- Mounting the Fixture:
- Position the fixture and mark the locations for mounting screws.
- Secure the fixture to the mounting surface using appropriate screws (not always included, refer to package contents). The rigid extruded aluminum body provides stable mounting.
- Electrical Connection:
- Connect the fixture to a suitable power source (120V AC) using the integrated cord. This is a corded electric unit.
- The fixture has a built-in electronic ballast.
- For linking multiple fixtures, ensure the total interconnected wattage does not exceed 600W.
- Lamp Installation (if not pre-installed):
- Carefully insert the T5 fluorescent lamp into the fixture's lamp holders. Ensure the pins are properly aligned.
- Final Check:
- Verify all connections are secure and the fixture is firmly mounted.
- Restore power at the circuit breaker.
Operating Instructions
The HERA SlimLite XL fixture is designed for simple operation:
- Power On/Off: The fixture is typically controlled by an external wall switch or a switch on the power cord (if applicable). Toggle the switch to turn the light on or off.
- Control Method: While some modern lighting systems use app control, this specific fixture (Model ES34.BC) primarily relies on a physical switch for operation.
Maintenance
Regular maintenance ensures optimal performance and longevity of your fixture.
- Cleaning:
- Before cleaning, ensure the fixture is turned OFF and has cooled down.
- Wipe the exterior surfaces with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners or solvents.
- Lamp Replacement:
- The fluorescent lamp has an approximate life of 20,000 hours.
- When the lamp reaches its end of life or fails, turn OFF the power to the fixture.
- Carefully remove the old lamp and replace it with a new T5 fluorescent lamp of the same wattage (21W) and color temperature (4100K) to maintain consistent lighting.
- Dispose of old fluorescent lamps according to local regulations.
Troubleshooting
If you encounter issues with your HERA SlimLite XL fixture, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fixture does not light up. | No power to the fixture. Lamp is faulty or not seated correctly. Ballast failure. | Check circuit breaker and wall switch. Ensure lamp is fully inserted; replace lamp if necessary. Contact a qualified electrician for ballast inspection/replacement. |
| Light flickers or hums. | Lamp nearing end of life. Incorrect lamp type. Ballast issue. | Replace the lamp. Ensure correct T5 21W lamp is used. Consult an electrician. |
| Fixture is hot to the touch. | Improper ventilation. Incorrect lamp wattage. | Ensure adequate airflow around the fixture. Verify lamp wattage matches fixture specifications (21W). |
If the problem persists after attempting these solutions, contact a qualified electrician or HERA customer support.
Specifications
| Attribute | Detail |
|---|---|
| Brand | HERA |
| Model Number | ES34.BC |
| Product Dimensions | 34.88 x 0.91 x 1.31 inches |
| Item Weight | 1.4 Pounds |
| Light Source Wattage | 21 Watts |
| Total Wattage (Fixture) | 22 Watts |
| Color Temperature | 4100 Kelvin (Cool Fluorescent) |
| Material | Aluminum |
| Power Source | Corded Electric |
| Lamp Life | Approximately 20,000 hours |
| Maximum Interconnected Wattage | 600 Watts |
| Switch Installation Type | Snap-in |
| Base Type | T Type (for T5 lamp) |
Warranty and Support
For information regarding warranty coverage, technical support, or replacement parts for your HERA SlimLite XL fixture, please refer to the official HERA Lighting website or contact their customer service directly. Keep your purchase receipt as proof of purchase.
HERA Lighting Contact Information: Please visit HERA Store on Amazon or the official HERA Lighting website for the most current contact details.