1. Introduction
The WAYNE PC2 Portable Electric Water Transfer Pump is designed for efficient water removal from various sources such as aquariums, clogged sinks, and for flushing water lines. This compact and powerful 120-volt pump includes a 6-foot suction hose, a water suction attachment, and a replacement parts kit. Its bronze-plated pump construction ensures durability and resistance to thread damage. The PC2 is capable of draining water down to 1/8 inch.
2. Safety Information
Please read and understand all safety instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Electrical Safety: Ensure the pump is connected to a properly grounded 120-volt AC outlet. Do not operate the pump with a damaged cord or plug. Keep all electrical connections dry.
- Water Contact: Avoid direct contact with water while the pump is operating. Do not use the pump in standing water where personnel are present.
- Operating Environment: Use the pump only for its intended purpose. Do not pump flammable liquids, corrosive chemicals, or liquids containing abrasive solids.
- Supervision: Do not leave the pump unattended during operation. Unplug the pump from the power source when not in use or during maintenance.
- Hearing Protection: The pump can be noisy during operation. Wear hearing protection, especially when operating indoors.
- Proposition 65 Warning: This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
3. Setup and Installation
Before starting, ensure all components are present: the PC2 pump, 6-foot suction hose, water suction attachment, and replacement parts kit.
- Connect Hoses:
- Attach the provided 6-foot suction hose to the inlet port of the pump. Ensure a secure connection.
- Connect a standard garden hose (not included) to the outlet port of the pump. Direct the discharge end of this hose to the desired drainage area.
- For applications requiring drainage down to 1/8 inch, attach the water suction attachment to the end of the suction hose that will be submerged in the liquid.
- Priming the Pump:
Although the WAYNE PC2 is designed to be self-priming, it is recommended to prime the pump for optimal performance, especially during the first use or after extended storage. Pour approximately one tablespoon of vegetable oil into both the inlet and outlet ports before connecting the hoses. Alternatively, for water transfer, you can prime the input hose with the liquid to be pumped.
- Positioning:
Place the pump on a stable, level surface. For increased stability, especially when hoses are moved, consider mounting the lightweight pump on a wood base.

Image: The WAYNE PC2 pump set up next to an aquarium, demonstrating the connection of the yellow suction hose into the tank and the green discharge hose from the pump's outlet. A hand is shown guiding the suction hose into the aquarium.
4. Operating Instructions
- Submerge Suction Hose: Ensure the end of the suction hose (with or without the attachment) is fully submerged in the liquid you intend to transfer.
- Direct Discharge: Confirm the discharge hose is directed to a suitable drainage location.
- Power On: Plug the pump's power cord into a grounded 120-volt AC electrical outlet. The pump will begin operating immediately as there is no power switch.
- Monitor Operation: Observe the pump's operation. It should start pumping water efficiently. The pump has a maximum flow rate of 340 gallons per minute.
- Power Off: To stop the pump, unplug the power cord from the electrical outlet.
- Post-Operation: After use, especially when pumping non-water liquids (e.g., vinegar for flushing tankless water heaters), flush the pump and hoses with clean water to prevent corrosion or damage.
5. Maintenance
Regular maintenance ensures the longevity and efficient operation of your WAYNE PC2 pump.
- Cleaning: After each use, especially when pumping dirty water or chemicals, flush the pump with clean water.
- Impeller and Gaskets: The pump comes with a replacement parts kit, which typically includes a replacement impeller, hose gasket, and motor brushes/springs. Refer to the detailed diagram in the full manual for instructions on replacing these components if wear is observed.
- Storage: Store the pump in a dry, protected area when not in use. Ensure all water is drained from the pump and hoses before storage to prevent freezing damage.
6. Troubleshooting
If your WAYNE PC2 pump is not operating as expected, consult the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start or run. | No power; tripped circuit breaker; faulty motor. | Check power connection and outlet. Reset circuit breaker. If motor is faulty, contact customer support. |
| Pump runs but does not pump water. | Pump not primed; air leak in suction line; suction hose not submerged; clogged impeller. | Ensure pump is primed. Check all suction hose connections for leaks. Verify suction hose is fully submerged. Inspect and clear impeller. |
| Low flow or reduced performance. | Partial clog in suction or discharge line; worn impeller; excessive lift height. | Check and clear any obstructions in hoses. Inspect impeller for wear and replace if necessary. Ensure pump is within its maximum lifting height specifications. |
| Pump is excessively noisy. | Air in pump; cavitation; worn bearings. | Ensure pump is properly primed and there are no air leaks. Check for obstructions at the suction inlet. If noise persists, contact customer support. |
7. Specifications
| Feature | Detail |
|---|---|
| Model Number | PC2 |
| Power Source | Corded Electric |
| Voltage | 120 Volts |
| Maximum Flow Rate | 340 Gallons Per Minute |
| Maximum Lifting Height | 6 Feet |
| Item Weight | 5.9 Pounds |
| Product Dimensions (L x W x H) | 7.6"L x 9"W x 9"H |
| Material | Bronze |
| Included Components | 6' Suction Hose, Water Suction Attachment, Replacement Parts Kit |
8. Warranty and Support
The WAYNE PC2 Portable Transfer Water Pump comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your product or visit the official Wayne website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Wayne customer service.
Manufacturer: Wayne
Website: www.wayne.com (Example, please refer to actual product documentation for official contact information)