This manual provides essential information for the proper installation, operation, and maintenance of the Selkirk 106036 6x3 Type B Gas Vent Chimney Pipe. Adherence to these instructions is crucial for safe and efficient performance. This pipe is designed for use with approved gas appliances in residential and light commercial and industrial applications.

Safety Information

Always prioritize safety when working with gas venting systems. Improper installation or maintenance can lead to serious hazards, including carbon monoxide poisoning, fire, or property damage.

Product Overview

The Selkirk 106036 is a 6-inch diameter by 3-foot long, round, Type B gas vent chimney pipe. It is designed for efficient and safe venting of approved gas appliances. Its construction features a durable 28 GA galvanized steel outer casing and an aluminum inner liner.

Key Features:

Product Images:

Selkirk 6x3 Gas Chimney Pipe

Figure 1: Selkirk 106036 6x3 Gas Chimney Pipe. This image shows the full length of the galvanized steel pipe, designed for venting gas appliances.

Selkirk 6x3 Gas Chimney Pipe with Dimensions

Figure 2: Selkirk 106036 Gas Chimney Pipe with indicated dimensions. The pipe measures 36 inches (3 feet) in length and 6 inches in diameter.

Setup and Installation

The Selkirk 106036 pipe is designed for straightforward assembly. However, due to the critical nature of gas venting, professional installation is strongly recommended to ensure compliance with all safety standards and local building codes.

General Guidelines:

  1. Review Local Codes: Before beginning any installation, consult local building codes and regulations regarding gas appliance venting.
  2. Appliance Manual: Always refer to the gas appliance manufacturer's installation manual for specific venting requirements and compatible pipe types.
  3. Assembly: The pipe sections are designed for easy connection. Ensure each connection is secure and forms a tight seal to prevent gas leaks. Multiple sections can be combined to achieve the necessary vent height.
  4. Support: Ensure the vent system is adequately supported throughout its length according to manufacturer guidelines and local codes.
  5. Clearances: Maintain required clearances from combustible materials as specified by the pipe and appliance manufacturers.
  6. Termination: Ensure the vent terminates correctly outdoors, away from windows, doors, and air intakes, and above the roofline as per code.

Note: This pipe is specifically a Type B gas vent, suitable only for Category I gas-fired appliances with draft hoods or appliances tested and listed for use with Type B gas vents. Do not use with oil, wood, or coal-burning appliances.

Operation

The Selkirk 106036 gas chimney pipe functions as a passive conduit for the safe exhaust of combustion byproducts from gas appliances. Its operation is entirely dependent on the proper functioning of the connected gas appliance and the correct installation of the entire venting system.

Maintenance

Regular maintenance is essential to ensure the continued safe and efficient operation of your gas venting system.

Troubleshooting

If you suspect an issue with your gas venting system, it is crucial to address it immediately. For safety, always consult a qualified professional for diagnosis and repair.

ProblemPossible CauseRecommended Action
Poor Draft / Appliance Not Venting
  • Blocked vent pipe (debris, animal nest)
  • Improper pipe sizing or length
  • Negative pressure in the building
  • Damaged pipe or connections
  • Immediately shut off the gas appliance.
  • Contact a qualified HVAC technician or chimney sweep for inspection and repair.
  • Do not operate the appliance until the issue is resolved.
Visible Corrosion or Damage to Pipe
  • Exposure to moisture or corrosive agents
  • Physical impact
  • Age/wear
  • Contact a professional for assessment.
  • Damaged sections may need replacement.

Warning: Never attempt to repair gas venting components yourself unless you are a certified professional. Always prioritize safety.

Specifications

AttributeDetail
Model Number106036
Product Dimensions36"L x 6"W (6 inches diameter x 3 feet length)
Item Weight4.9 pounds
MaterialOuter: 28 GA Galvanized Steel; Inner: Aluminum
ShapeRound
Installation TypeBolt-On (referring to connection method)
TypeType B Gas Vent Chimney Pipe
UPC053713126468

Warranty and Support

Specific warranty information for the Selkirk 106036 6x3 Gas Chimney Pipe should be obtained directly from the manufacturer, Selkirk, or your authorized dealer at the time of purchase. Warranty terms typically cover manufacturing defects.

For technical support, installation guidance, or warranty claims, please contact Selkirk customer service or the retailer from whom the product was purchased. Always provide your model number (106036) and purchase date when seeking support.

You can often find contact information on the manufacturer's official website or on the product packaging.

Related Documents - 106036

Preview Selkirk Ultra-Temp®/Galva-Temp® Chimney Catalog
Comprehensive catalog detailing Selkirk's Ultra-Temp® and Galva-Temp® chimney systems, including installation guides, technical specifications, and a wide range of compatible parts for various fuel types.
Preview Selkirk SWII Flexible Aluminum Chimney Liner & Gas Vent Connector Installation Guide
Detailed installation guide for the Selkirk Model SWII Flexible Aluminum Chimney Liner and Gas Vent Connector. Covers safety, preparation, step-by-step installation, and warranty for gas appliances.
Preview Selkirk DIRECT-TEMP® Co-Linear Insert Kit Installation Instructions
Comprehensive installation guide for the Selkirk DIRECT-TEMP® Co-Linear Insert Kit, detailing setup, safety precautions, and maintenance for direct vent gas inserts in masonry or factory-built chimneys.
Preview Selkirk Oval Gas Vent Installation Instructions for Type B Systems
Comprehensive installation guide for Selkirk Oval Gas Vent Type B systems, covering clearances, appliance compatibility, fittings, and multi-story installations. Essential for safe and proper venting of gas appliances.
Preview Selkirk DIRECT-TEMP Direct Vent System Installation Guide
Comprehensive installation guide for the Selkirk DIRECT-TEMP Direct Vent System, covering general use, installation steps, termination requirements, support methods, and safety precautions for direct vent gas appliances.
Preview Selkirk SuperVent 2100 / SuperPro 2100 Installation and Maintenance Guide
Comprehensive installation and maintenance guide for Selkirk SuperVent 2100 and SuperPro 2100 factory-built insulated chimneys. Covers safety, clearances, framing, installation procedures, and maintenance.