ABB TM1615RCU

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Instruction Manual

1. Safety Information

Important Safety Notice: Installation and servicing of this electrical equipment must be performed by qualified, licensed electricians in accordance with all applicable national and local electrical codes. Failure to do so can result in serious injury, death, or property damage.

Always disconnect power at the main service panel before working on or near the load center. Use appropriate personal protective equipment (PPE) including insulated gloves, safety glasses, and non-conductive tools.

For your safety, it is crucial to purchase only genuine, ABB-manufactured electrical products (inclusive of those branded GE or GE by ABB and now manufactured by ABB). Counterfeit and non-authentic products may fail to meet safety standards, putting you at risk. To ensure you receive safe, reliable products, check the product description and photos and verify that the product is described as an ABB, GE, or GE by ABB product and has labels with an ABB, GE, or GE by ABB logo. Please also check the product description to see if the product has been certified by third-party certification bodies such as UL, IC and/or Intertek.

This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (Proposition 65 warning).

2. Product Overview

The ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center is designed for reliable electrical distribution in outdoor residential or light commercial applications. This unit features a 150 Amp main breaker, 16 one-inch spaces, and is suitable for 120/240VAC, single-phase, 3-wire systems with top feed configuration.

Key Features:

  • Power-mark gold 150A main breaker outdoor load center.
  • 16 - 1 inch spaces, 120/240VAC, single phase, 3 wire, top feed.
  • Main breaker factory installed.
  • Durable construction with high-grade copper materials.
  • Designed for outdoor use.

Product Views:

Front view of the ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Figure 2.1: Front view of the load center with the cover closed, showing its light gray finish and rectangular shape.

Internal angled view of the ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Figure 2.2: Angled internal view of the load center, revealing the main breaker, bus bars, and wiring terminals. Labels for "TOP" and "QUALITY GATE" are visible.

Back view of the ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Figure 2.3: Back view of the load center, showing multiple knockouts for conduit entry at the bottom and top, and mounting points.

Internal straight view of the ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Figure 2.4: Straight internal view of the load center, providing a clear look at the main breaker, neutral bar, ground bar, and circuit breaker slots.

Side view 1 of the ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Figure 2.5: Side view of the load center, showing its depth and the side profile of the enclosure.

Side view 2 of the ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center

Figure 2.6: Opposite side view of the load center, providing another perspective of its enclosure design.

3. Setup and Installation

Professional Installation Required: Due to the inherent dangers of working with high voltage electricity, the installation of the TM1615RCU load center must be performed by a qualified and licensed electrician. This manual provides general information and is not a substitute for professional expertise or adherence to local electrical codes.

3.1 Pre-Installation Checks:

  • Verify that the load center specifications (voltage, amperage, number of spaces) match the requirements of the installation site.
  • Ensure all necessary tools and materials are available, including appropriate wiring, conduit, and mounting hardware.
  • Confirm that the installation location is suitable for an outdoor electrical enclosure, providing adequate clearance and protection from physical damage.

3.2 Mounting:

  • Select a flat, stable, and accessible surface for mounting.
  • Use appropriate fasteners to securely attach the load center to the mounting surface. Ensure the enclosure is level and plumb.

3.3 Wiring:

  • All wiring must comply with the National Electrical Code (NEC) and local building codes.
  • Connect the main service conductors to the main breaker terminals.
  • Install branch circuit breakers into the designated slots and connect the load conductors.
  • Properly connect neutral and ground conductors to their respective bus bars.
  • Ensure all connections are tight and secure to prevent loose connections and potential hazards.

After wiring, replace the cover securely. Do not energize the system until all connections have been double-checked and the installation is complete and inspected by a qualified professional if required by local regulations.

4. Operating Instructions

The TM1615RCU load center is designed for straightforward operation once installed. Its primary function is to safely distribute electrical power to various circuits and provide overcurrent protection.

4.1 Circuit Breaker Function:

  • Each circuit breaker protects a specific electrical circuit from overloads and short circuits.
  • In normal operation, circuit breakers are in the "ON" position.
  • If an overload or short circuit occurs, the breaker will automatically "trip" to the "OFF" or center position, interrupting power to that circuit.

4.2 Resetting a Tripped Circuit Breaker:

  1. Identify the Cause: Before resetting, try to determine what caused the breaker to trip (e.g., too many appliances on one circuit, a faulty appliance). Address the issue if possible.
  2. Turn OFF: Firmly push the tripped breaker's handle completely to the "OFF" position. You may hear a click.
  3. Turn ON: Firmly push the breaker's handle to the "ON" position.
  4. If the breaker immediately trips again, do not attempt to reset it repeatedly. There is likely a persistent electrical fault that requires professional attention.

4.3 Main Breaker Operation:

The 150A main breaker controls all power to the load center. To completely de-energize the entire panel, switch the main breaker to the "OFF" position. This should only be done by a qualified individual for maintenance or emergency purposes.

5. Maintenance

Regular inspection and maintenance can help ensure the longevity and safe operation of your load center. All maintenance procedures should be performed by a qualified electrician with the power disconnected.

5.1 Periodic Inspection (Annual):

  • Visually inspect the exterior of the load center for any signs of damage, corrosion, or water ingress.
  • With power off, open the cover and inspect for loose wires, discolored insulation (indicating overheating), or signs of rodent activity.
  • Check that all circuit breakers are securely seated in their positions.
  • Ensure all screws on terminals and bus bars are tight.

5.2 Cleaning:

  • Keep the exterior of the load center clean and free of debris.
  • If cleaning the interior, ensure power is completely off. Use a dry, soft brush or vacuum cleaner to remove dust and debris. Do not use liquids or abrasive cleaners.

Do not attempt to modify the load center or its internal components. Any modifications can compromise safety and void the warranty.

6. Troubleshooting

This section provides basic troubleshooting steps for common issues. For complex problems or if you are unsure, always consult a qualified electrician.

ProblemPossible CauseSolution
Circuit breaker trips frequently.Overloaded circuit, short circuit, or faulty appliance/wiring.Reduce load on the circuit. Unplug appliances. If problem persists, contact an electrician to check for short circuits or faulty wiring.
No power to entire load center.Main breaker tripped, utility power outage, or issue with service entrance.Check if the main breaker is in the "OFF" or tripped position and reset it. Verify if there's a power outage in your area. If not, contact your utility company or an electrician.
Burning smell or unusual noises from load center.Loose connections, overheating, or internal fault.Immediately disconnect power at the source if safe to do so. Do not attempt to open or inspect. Contact a qualified electrician immediately. This is a serious safety hazard.

Always prioritize safety. If you are unsure about any electrical issue, do not attempt to fix it yourself. Contact a licensed electrician.

7. Specifications

AttributeDetail
BrandABB
Model NumberTM1615RCU
Product Dimensions13.6"L x 4.47"W x 4.6"H
AC Adapter Current150 Amps
MaterialCopper
Number Of Circuits16
Item Weight3.72 pounds
ColorLight Gray
Item Package Quantity1
Included Components150 Amp 16-Space 32-Circuit Outdoor Main Breaker Circuit Breaker Panel
UPC723902350744, 783164113105

8. Warranty and Support

For warranty information regarding your ABB TM1615RCU Powermark Gold 150A Main Breaker Outdoor Load Center, please contact the manufacturer's customer service directly. You may also be able to find warranty information on the manufacturer's website.

ABB acquired GE's Industrial Solutions business in 2018 and continues to manufacture GE, GE by ABB, and ABB branded products under a license from GE.

For technical support or inquiries not covered in this manual, please refer to the official ABB support channels or consult a certified electrician.

© 2023 ABB. All rights reserved. This manual is for informational purposes only.