1. Introduction
Thank you for choosing the Cadet 79241 Compact Electric Wall Heater. This manual provides essential information for the safe installation, operation, and maintenance of your new heater. The Cadet 79241 is a 1000-watt, 120-volt, 8.33-amp fan-forced electric wall heater designed for efficient heating in areas up to 150 square feet, such as bathrooms and workspaces. It features a nichrome coil element and an on/off switch for manual control. This product is UL listed, ensuring it meets recognized safety standards.
2. Important Safety Information
Please read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in fire, electric shock, property damage, or personal injury.
- Electrical Safety: Always disconnect power at the main service panel before installing, servicing, or cleaning the heater. Ensure all wiring connections are secure and comply with local electrical codes.
- Placement: Do not install the heater directly below a wall receptacle. Maintain proper clearances from combustible materials as specified in the installation instructions.
- Operation: Never block the air intake or exhaust vents. Do not insert any objects into the heater openings. Do not use this heater in wet or moist locations, or near bathtubs, showers, or swimming pools.
- Supervision: Close supervision is necessary when any heater is used by or near children or invalids.
- Proposition 65 Warning: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
3. Product Overview
The Cadet 79241 is a compact, fan-forced electric wall heater designed for supplemental heating. Its robust construction and simple controls make it suitable for various residential and commercial applications.
Key Features:
- 1000 Watts, 120 Volts, 8.33 Amps
- Fan-forced heating for quick warmth
- Integrated on/off switch for manual control
- Nichrome coil element for continuous heat transmission
- UL Listed for safety
- Ideal for heating up to 150 square feet

Figure 1: Front view of the Cadet 79241 Compact Electric Wall Heater, showing the grille and on/off switch.

Figure 2: View of the Cadet 79241 heater with its internal components, including the fan and heating element, exposed for installation reference.
4. Installation
Installation of the Cadet 79241 heater requires hard-wiring to a dedicated 120-volt circuit. It is recommended that installation be performed by a qualified electrician to ensure compliance with all local and national electrical codes.
Pre-Installation Steps:
- Power Disconnection: Turn off power to the circuit at the main electrical panel before beginning any installation work.
- Location Selection: Choose a wall location that allows for proper clearances from floors, ceilings, and adjacent walls. Ensure the location is not obstructed by furniture or drapes. The heater is designed for use with a wall can, such as model RBFC (sold separately).
- Wiring: Run appropriate gauge electrical wiring (rated for 120V, 8.33A, 1000W) to the installation site.
Mounting the Heater:
- Secure the wall can (if used) into the wall opening according to its instructions.
- Connect the heater's wiring to the building's electrical supply wires inside the junction box, following the wiring diagram provided with the heater. Ensure all connections are tight and properly insulated.
- Carefully insert the heater assembly into the wall can or wall opening, securing it with the provided screws.
- Attach the front grille to the heater assembly.

Figure 3: The Cadet 79241 Compact Electric Wall Heater shown installed flush on a wall, providing a visual reference for proper placement.
5. Operation
The Cadet 79241 Compact Electric Wall Heater is designed for straightforward operation using its integrated on/off switch.
Turning the Heater On/Off:
- To turn the heater ON, locate the switch on the front panel of the heater and toggle it to the 'ON' position. The fan will activate, and the heating element will begin to produce warm air.
- To turn the heater OFF, toggle the switch to the 'OFF' position. The fan and heating element will cease operation.
This heater provides fan-forced heat, distributing warmth quickly and efficiently throughout the designated area. It is manually controlled via the on/off switch and does not feature an integrated thermostat.
6. Maintenance
Regular, simple maintenance will help ensure the longevity and efficient operation of your Cadet 79241 heater.
Cleaning:
- Disconnect Power: Always turn off the heater and disconnect power at the main service panel before cleaning.
- Exterior Cleaning: Use a soft, damp cloth to wipe the exterior surfaces of the heater. Do not use abrasive cleaners, solvents, or spray cleaners directly on the heater.
- Grille Cleaning: Use a vacuum cleaner with a brush attachment to gently remove dust and debris from the grille openings.
No other user-serviceable parts are inside the heater. Any internal maintenance or repair should be performed by qualified service personnel.
7. Troubleshooting
If your Cadet 79241 heater is not operating correctly, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater does not turn on. | No power to the unit. | Check the circuit breaker at the main electrical panel. Ensure the on/off switch is in the 'ON' position. |
| Heater produces no heat, but fan runs. | Heating element issue. | Disconnect power and contact a qualified electrician or service technician. |
| Reduced heat output. | Blocked air vents or dust accumulation. | Disconnect power and clean the grille and air vents as described in the Maintenance section. Ensure no objects are blocking airflow. |
| Unusual noises during operation. | Loose components or fan obstruction. | Disconnect power immediately. Do not attempt to repair. Contact a qualified service technician. |
If you are unable to resolve an issue using this guide, please contact Cadet customer support or a qualified electrician.
8. Specifications
Detailed technical specifications for the Cadet 79241 Compact Electric Wall Heater:
- Model Number: 79241
- Voltage: 120 Volts
- Wattage: 1000 Watts
- Amperage: 8.33 Amps
- Heating Method: Fan Forced Air
- Heating Coverage: Approximately 150 square feet
- Product Dimensions: 3.88 x 10.13 x 16.88 inches (Depth x Width x Height)
- Item Weight: 1 pound
- Manufacturer: TV Non-Branded Items (Cadet)
- UL Listed: Yes
9. Warranty and Support
Specific warranty information for the Cadet 79241 Compact Electric Wall Heater is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact Cadet customer support directly.
Customer Support:
For technical assistance, replacement parts, or further inquiries, please visit the official Cadet website or contact their customer service department. Contact information can typically be found on the product packaging or the manufacturer's website.