MUELLER 104-827HC

Mueller Industries 1/2" X 10" Wall Hydrant Instruction Manual

Model: 104-827HC

Brand: MUELLER

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Mueller Industries 1/2" X 10" B & K 104-827HC Wall Hydrant. Designed for residential and commercial applications, this frost-free sillcock valve offers convenient outdoor water access with built-in features for reliable performance.

Safety Information

WARNING:

Product Overview and Components

The Mueller Industries 104-827HC Wall Hydrant is a robust plumbing fixture designed for outdoor use. Key components and features include:

Mueller Industries 1/2 inch by 10 inch Wall Hydrant
Image: Mueller Industries 1/2" X 10" Wall Hydrant. This image displays the complete wall hydrant assembly, showing the main body, the quarter-turn handle, the chrome-plated tube, and the threaded connection end.

Setup and Installation

Proper installation is crucial for the optimal performance and longevity of your wall hydrant. It is recommended that installation be performed by a qualified professional.

  1. Prepare Water Supply: Ensure the main water supply to the installation area is completely shut off. Drain any residual water from the pipes.
  2. Select Location: Choose a suitable exterior wall location, ensuring there is adequate space inside the wall for the hydrant's length (10 inches).
  3. Create Opening: Drill or cut a single hole through the exterior wall, large enough to accommodate the hydrant's body.
  4. Connect to Water Line:
    • For threaded connections, apply Teflon tape or pipe sealant to the threads of the water supply line.
    • For solder connections, properly clean and flux the pipe and the hydrant's connection point before soldering.

    Note: A mark on the top of the threaded end indicates the correct alignment for the faucet.

  5. Mount the Hydrant: Insert the hydrant through the wall opening. Use the notched flange to secure the hydrant stably against the siding or brick. Fasten it securely to the wall structure using appropriate screws (not included).
  6. Check for Leaks: Once installed, slowly turn on the main water supply and carefully inspect all connections for any signs of leaks.

Operating Instructions

Operating your Mueller Industries Wall Hydrant is straightforward:

  1. To Turn On: Rotate the handle a quarter turn counter-clockwise. Water will begin to flow from the spout.
  2. To Turn Off: Rotate the handle a quarter turn clockwise until it stops. The water flow will cease, and the sillcock will automatically drain any remaining water from the tube, ensuring its frost-free function.
  3. Backflow Prevention: The integrated backflow preventer automatically protects your potable water supply from contamination by preventing water from flowing back into the system.

Maintenance

Regular maintenance ensures the longevity and proper function of your wall hydrant:

Troubleshooting

ProblemPossible CauseSolution
No water flow or low pressureMain water supply off; Clogged line; Valve not fully open.Ensure main water supply is on; Check for obstructions in the line; Fully open the valve with a quarter turn.
Water drips from spout after shut-offHose connected; Internal valve issue; Incomplete drainage.Disconnect any attached hoses to allow complete drainage; If problem persists, internal components may need inspection by a plumber.
Leak at connectionsLoose connection; Damaged threads/sealant.Tighten connections (do not overtighten); Reapply Teflon tape or pipe sealant if necessary.
Handle is broken or loosePhysical damage; Loose screw.Inspect the handle and its attachment screw. Tighten the screw if loose. If broken, contact Mueller Industries for replacement parts.

Specifications

AttributeDetail
ManufacturerMueller Industries
Part Number104-827HC
Item Weight1.24 pounds
Product Dimensions14.52 x 2.48 x 3.17 inches
Size1/2" X 10"
ColorNo Color (Handle is putty colored)
FinishPlated, Chrome
MaterialBrass (Body), Plastic (Handle)
Installation MethodSingle Hole
Mounting TypeWall Mount
Special FeaturesLead Free, Frost-Free, Built-in Backflow Preventer, Quarter-Turn Operation

Warranty and Support

This Mueller Industries product comes with a manufacturer's warranty. For specific details regarding warranty coverage, claims, or technical support, please refer to the warranty information provided with your purchase or contact Mueller Industries directly through their official website or customer service channels.

For replacement parts or further assistance, please provide your product model number (104-827HC) and purchase date when contacting support.

Related Documents - 104-827HC

Preview Mueller Professional Steam Iron MLR010002N User Manual
Comprehensive user manual for the Mueller Professional Steam Iron (Model MLR010002N), detailing safety instructions, parts overview, usage, cleaning, troubleshooting, and specifications for optimal performance.
Preview Mueller FoodFresh Vacuum Sealer MV-1100 Instruction Manual
Comprehensive instruction manual for the Mueller FoodFresh Vacuum Sealer Model MV-1100, covering features, operation, safety, troubleshooting, and storage tips for optimal food preservation.
Preview Müeller ULTRA Yogurt Maker YL-470 User Manual and Guide
Comprehensive guide for the Müeller ULTRA Yogurt Maker (Model YL-470), covering safety instructions, parts identification, ingredients, step-by-step usage, tips for best results, flavoring suggestions, cleaning, and technical specifications.
Preview Mueller NO-BLO® Line Stopper Fittings: Specifications and Selection Guide
Comprehensive guide to Mueller NO-BLO® line stopper fittings, detailing specifications, model numbers (H-17055, H-17056, etc.), pressure ratings, sizes, and selection charts for safe and efficient pipe stopping operations.
Preview Mueller Drilling & Tapping Machines: Rugged, Dependable Water Service Equipment
Comprehensive guide to Mueller's line of drilling and tapping machines, including models like B-101, D-5, EZ-TAP, and Mega-Lite. Learn about their features, applications, and accessories for efficient water service connections. Mueller is a leading supplier of water infrastructure products.
Preview Mueller Fire Hydrant Reference Manual: Model Specifications, Parts, and Troubleshooting
The official Mueller Fire Hydrant Reference Manual provides detailed specifications, parts lists, ordering information, and troubleshooting guides for Mueller's extensive range of fire hydrants, including Super Centurion, Centurion, and Hi-Flo models.