1. Introduction
Thank you for choosing the Severin DR 8201 Handheld Steam Cleaner. This powerful and versatile appliance is designed to provide effective and hygienic cleaning for various surfaces in your home using only steam, eliminating the need for harsh chemicals. Please read this instruction manual carefully before first use to ensure safe and optimal operation of your device.
2. Safety Instructions
Always observe the following safety precautions to prevent injury or damage to the appliance:
- Ensure the voltage indicated on the rating label matches your mains voltage.
- Do not immerse the appliance, cord, or plug in water or other liquids.
- Keep the steam nozzle away from people, animals, and electrical appliances. Steam is very hot and can cause burns.
- Do not open the water tank cap while the appliance is pressurized or hot. Allow it to cool down completely before refilling.
- Use only distilled or demineralized water to prevent limescale buildup.
- Unplug the appliance from the mains socket after use and before cleaning or maintenance.
- This appliance is intended for household use only.
3. Package Contents
Please check that all items are present and in good condition:
- Severin DR 8201 Handheld Steam Cleaner Unit
- Steam Nozzle
- Brush for narrow spaces
- Window Cleaner Attachment
- Shoulder Strap
- Extension Tube
- Measuring Cup
- Funnel

Figure 3.1: Included accessories for the Severin DR 8201 steam cleaner, including various nozzles, brushes, and a measuring cup.
4. Setup
- Ensure the appliance is unplugged and cool.
- Unscrew the safety cap of the water tank by turning it counter-clockwise.
- Using the provided measuring cup and funnel, carefully fill the water tank with up to 330 ml of distilled or demineralized water. Do not overfill.
- Screw the safety cap back on tightly by turning it clockwise until secure.
- Attach the desired accessory (e.g., steam nozzle, brush) firmly to the steam outlet.
- Plug the appliance into a suitable mains socket. The indicator light will illuminate, indicating the appliance is heating up.

Figure 4.1: The main unit of the Severin DR 8201 handheld steam cleaner, showing the water tank cap and steam outlet.
5. Operating Instructions
Once the indicator light turns off (or changes color, depending on model), the steam cleaner is ready for use. This typically takes a few minutes.
5.1 General Operation
- Point the nozzle away from yourself and others.
- Press and hold the steam release button to emit steam. Release the button to stop the steam flow.
- Move the steam cleaner slowly over the surface to be cleaned. For stubborn dirt, hold the steam over the area for a few seconds.
- Wipe the steamed surface with a clean cloth if necessary.
5.2 Specific Applications
- Bathrooms & Kitchens: Use the brush attachment for grout, tiles, and fixtures. Steam helps to loosen grime and disinfect surfaces.
- Glass & Mirrors: Attach the window cleaner tool. Steam the surface, then use the squeegee to wipe clean. For best results, wipe with a microfiber cloth afterwards.
- Furniture & Upholstery: Use the steam nozzle or a cloth over the nozzle. Test on an inconspicuous area first. Steam can refresh fabrics and remove odors.
- Sterilization: Hold the steam nozzle directly over the surface for at least 10 seconds to effectively sanitize.

Figure 5.1: Examples of the Severin DR 8201 steam cleaner being used for various cleaning tasks, including bathroom surfaces and windows.
6. Maintenance and Cleaning
Regular maintenance ensures the longevity and efficiency of your steam cleaner.
- After Each Use: Unplug the appliance and allow it to cool completely. Carefully unscrew the safety cap and empty any remaining water from the tank.
- Cleaning the Exterior: Wipe the exterior of the appliance with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Cleaning Accessories: Rinse attachments under running water. For stubborn residue, use a mild detergent. Ensure they are dry before storing.
- Descaling: If you notice reduced steam output or mineral buildup, descale the appliance. Consult a qualified service technician or refer to specialized descaling instructions for steam cleaners. Using distilled water regularly will minimize the need for descaling.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No steam output. | Water tank is empty or low. Appliance not heated. | Refill water tank. Wait for indicator light to turn off/change color. |
| Steam output is weak. | Limescale buildup. Nozzle blocked. | Descale the appliance. Clean the nozzle. |
| Water leaking from nozzle. | Accessory not properly attached. Overfilled water tank. | Ensure accessory is firmly attached. Do not overfill water tank. |
8. Specifications
- Model: DR 8201
- Power: 1000 W
- Water Tank Capacity: 330 ml
- Color: White
- Power Source: Corded Electric
- Special Feature: Portable
- Recommended Surfaces: Sealed hard floors, kitchen and bathroom surfaces, windows, upholstery
9. Warranty and Support
Severin products are manufactured to high-quality standards. For warranty information, please refer to the warranty card included with your purchase or visit the official Severin website. For technical support, spare parts, or service inquiries, please contact Severin customer service through their official channels. Keep your proof of purchase for warranty claims.
For more information, visit: www.severin.com