Rittal 3110000

Rittal 3110.000 Thermostat Instruction Manual

Model: 3110000

1. Product Overview

The Rittal 3110.000 is an internal enclosure thermostat designed for precise temperature control within industrial and IT enclosures. This device operates on 24/230V AC or 24/60V DC power supplies and features a compact design with dimensions of 2.8" Height x 2.8" Width x 1.32" Depth. It is equipped with a time-saving connection technique via a terminal strip with an external screw connection, simplifying installation and wiring.

This thermostat is ideal for maintaining optimal environmental conditions for sensitive equipment by regulating heating or cooling elements within an enclosure.

Rittal 3110.000 Thermostat front view with dial and wiring terminals

Figure 1: Front view of the Rittal 3110.000 Thermostat, showing the temperature adjustment dial and clearly labeled wiring terminals for various voltage inputs and outputs.

2. Safety Information

Before installation or operation, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure power is disconnected before performing any installation, wiring, or maintenance.
  • Installation should only be performed by qualified personnel in accordance with all local and national electrical codes.
  • Do not expose the thermostat to moisture or extreme temperatures outside its specified operating range.
  • Verify correct voltage and current ratings before connecting the device.
  • Use appropriate personal protective equipment (PPE) during installation.

3. Installation and Setup

The Rittal 3110.000 thermostat is designed for easy mounting and wiring within an enclosure.

3.1 Mounting

The thermostat can be mounted on a 35 mm DIN rail (EN 60715) or fixed with screws. Ensure adequate air circulation around the device for accurate temperature sensing.

  • Select a mounting location within the enclosure that is representative of the overall internal temperature and away from direct heat sources or cooling vents.
  • For DIN rail mounting: Snap the thermostat onto the DIN rail until it clicks into place.
  • For screw mounting: Use appropriate screws to secure the thermostat through its designated mounting holes.

3.2 Wiring

The thermostat features a terminal strip with external screw connections for simplified wiring. Refer to the wiring diagram below and the labels on the device for correct connections.

Rittal 3110.000 Thermostat with wiring labels

Figure 2: Top-down view of the Rittal 3110.000 Thermostat, highlighting the terminal block with clear voltage and function labels (N, 48V, 60V, 24V, L, 250V, 110V) and symbols for heating and cooling outputs.

Connection Terminals:

  • Terminals 1-2 (N, 48V/60V): Power supply for DC applications.
  • Terminals 3-4 (Heating Symbol): Normally Closed (NC) contact for connecting heating elements. This contact opens when the set temperature is reached.
  • Terminals 5-6 (Cooling Symbol): Normally Open (NO) contact for connecting cooling elements (e.g., fans). This contact closes when the set temperature is exceeded.
  • Terminals 6-7 (L, 250V/110V): Power supply for AC applications.

Ensure all connections are secure and properly insulated. Double-check wiring against the specific application requirements before applying power.

4. Operating Instructions

The Rittal 3110.000 thermostat is simple to operate, primarily involving setting the desired temperature.

4.1 Setting the Temperature

The thermostat features a rotary dial on its front face for temperature adjustment. The dial is marked in degrees Celsius (°C).

Rittal 3110.000 Thermostat with dimensions

Figure 3: Side view of the Rittal 3110.000 Thermostat, illustrating its compact dimensions (2.8" H x 2.8" W x 1.32" D) and the temperature adjustment dial.

  1. Locate the black rotary dial on the front of the thermostat.
  2. Rotate the dial clockwise or counter-clockwise to align the white indicator arrow with your desired temperature setting.
  3. For heating applications, the heating element will activate when the enclosure temperature falls below the set point and deactivate when it rises above.
  4. For cooling applications, the cooling element will activate when the enclosure temperature rises above the set point and deactivate when it falls below.

The thermostat's internal sensor will continuously monitor the enclosure temperature and switch the connected heating or cooling device on or off to maintain the set temperature.

5. Maintenance

The Rittal 3110.000 thermostat is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can ensure optimal performance.

  • Cleaning: Periodically clean the exterior of the thermostat with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Connections: Annually inspect all electrical connections to ensure they remain tight and free from corrosion.
  • Airflow: Ensure that the air vents on the thermostat are not obstructed, as this can affect temperature sensing accuracy.
  • Calibration: The thermostat is factory-calibrated and generally does not require re-calibration. If you suspect a significant deviation in temperature readings, consult a qualified technician.

Warning: Always disconnect power to the enclosure before performing any maintenance.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your Rittal 3110.000 thermostat.

ProblemPossible CauseSolution
Device not powering on.No power supply; incorrect wiring; blown fuse/breaker.Check power source. Verify wiring connections (refer to Section 3.2). Check and reset circuit breaker or replace fuse.
Heating/Cooling element not activating.Incorrect temperature setting; faulty wiring to element; element malfunction; thermostat malfunction.Adjust temperature setting. Verify wiring to heating/cooling element. Test the element independently. If issues persist, consult support.
Inaccurate temperature control.Obstructed airflow to sensor; thermostat mounted in non-representative location; faulty sensor.Ensure clear airflow around the thermostat. Relocate thermostat if necessary to a more central area. If suspected faulty sensor, contact support.
Thermostat clicks but element doesn't activate.Relay operating but no power to element; element wiring issue.Check power supply to the element. Inspect wiring between thermostat output and element.

If you are unable to resolve an issue using the troubleshooting guide, please contact Rittal customer support.

7. Specifications

Detailed technical specifications for the Rittal 3110.000 Thermostat:

  • Model Number: 3110000
  • Brand: Rittal
  • Product Type: Enclosure Internal Thermostat
  • Dimensions (D x W x H): 1.32" x 2.8" x 2.8"
  • Controller Type: Push Button
  • Special Feature: Temperature Display
  • Voltage (AC): 24/230V
  • Voltage (DC): 24/60V
  • Connection Technique: Terminal strip with external screw connection
  • Mounting: 35 mm DIN rail (EN 60715) or screw fixing
  • First Available Date: August 6, 2012
  • Manufacturer: Rittal LLC

8. Warranty and Support

Rittal products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Rittal website.

For technical support, service, or inquiries regarding your Rittal 3110.000 Thermostat, please contact Rittal customer service:

When contacting support, please have your product model number (3110000) and any relevant purchase information ready.

Related Documents - 3110000

Preview Rittal Speed Control EC 3235.460: Assembly and Operating Instructions
Official assembly and operating instructions for the Rittal Speed Control EC unit (Model 3235.460). Covers application, safety, functional description, electrical connection, technical data, and warranty for Rittal enclosure climate control systems.
Preview Rittal SK 3114.200 Digital Enclosure Internal Temperature Display and Thermostat
Technical specifications and features of the Rittal SK 3114.200, a digital enclosure internal temperature display and thermostat with a three-digit, 7-segment display, NTC sensor, and two relay outputs. Includes operating temperature, setting range, and voltage information.
Preview Rittal Speed Control EC 3235.460 Assembly and Operating Instructions
Assembly and operating instructions for the Rittal Speed Control EC 3235.460, a microprocessor-controlled thermostat for regulating enclosure internal temperature via EC fan-and-filter units. Includes technical data, safety information, and electrical connections.
Preview Rittal Blue e+ Refrigeradores para Armarios de Distribución: Manual de Instalación y Operación
Manual de Rittal que detalla el montaje, instalación y operación de los refrigeradores Blue e+ para armarios de distribución (modelos SK 3178800 a SK 3184840), incluyendo seguridad, especificaciones y mantenimiento.
Preview Rittal One-Piece Consoles: Assembly and Operating Instructions
Comprehensive assembly and operating instructions for Rittal's one-piece consoles (TP series), covering safety, installation, maintenance, and technical specifications. Includes guidance for various models like TP 6746.600, TP 6748.600, TP 6740.600, and TP 6742.600.
Preview Rittal RiTherm Manual: Climate Control Planning Software
A comprehensive manual for Rittal RiTherm, a free software tool for enclosure climate control planning, including features for energy-efficiency calculation, CO2 footprint analysis, and F-gas information.