GoldStar R5050

GoldStar R5050 5,000-Btu Air Conditioner User Manual

Model: R5050

1. Product Overview

The GoldStar R5050 is a compact 5,000-Btu window air conditioner designed for efficient cooling in smaller spaces, typically up to a 10-by-15-foot room. It features straightforward manual controls, including two cooling settings, two fan-only settings, and a nine-setting thermostat for precise temperature management. The unit also includes simple control tabs for adjusting horizontal airflow and a turbo fan for even cooling distribution. A washable air filter helps maintain air quality. With its low-profile, off-white housing, the R5050 boasts a 9.7 Energy Efficiency Rating (EER) and is designed for window installation, requiring a minimum window height of 13 inches and width of 22 inches.

Front view of the GoldStar R5050 5,000-Btu Air Conditioner, showing the control knobs and air vents.

Figure 1: Front view of the GoldStar R5050 Air Conditioner, highlighting the manual control knobs for operation and thermostat, along with the horizontal air vents.

2. Key Features

3. Safety Information

Please read all safety instructions carefully before installing and operating your air conditioner. Failure to follow these instructions may result in electric shock, fire, or personal injury.

4. Setup and Installation

The GoldStar R5050 is designed for window installation. Proper installation is crucial for optimal performance and safety.

4.1 Window Requirements

4.2 Installation Steps (General Guidelines)

  1. Prepare the Window: Clean the window sill and frame.
  2. Attach Side Panels: Secure the accordion side panels to the unit if they are not pre-attached.
  3. Place Unit in Window: Carefully lift the air conditioner and place it into the window opening, ensuring the bottom rail rests securely on the window sill.
  4. Secure the Unit: Extend the side panels to fill the window opening and secure them with screws or brackets as per the detailed installation guide (not provided here, refer to full product manual).
  5. Seal Gaps: Use foam strips or weatherstripping to seal any gaps around the unit to prevent air leakage and improve efficiency.
  6. Plug In: Once securely installed, plug the unit into a grounded 127 Volt outlet.

5. Operating Instructions

The GoldStar R5050 features simple manual controls for ease of use.

5.1 Control Panel Overview

The front panel of your air conditioner features two rotary knobs:

5.2 Setting the Operation Mode

Rotate the Operation knob to select your desired setting:

5.3 Adjusting the Thermostat

Rotate the Thermostat knob to set the desired room temperature. The knob typically ranges from 1 (warmest) to 9 (coolest). Start with a mid-range setting (e.g., 5 or 6) and adjust as needed for comfort.

5.4 Adjusting Airflow Direction

The unit features horizontal air deflection tabs located on the front grille. Manually adjust these tabs to direct the airflow left or right, ensuring even cooling distribution throughout the room.

6. Maintenance

Regular maintenance ensures optimal performance and extends the life of your air conditioner.

6.1 Cleaning the Air Filter

The GoldStar R5050 is equipped with a washable air filter. It is recommended to clean the filter every two weeks, or more frequently if the unit is used heavily or in dusty environments.

  1. Disconnect Power: Always unplug the air conditioner from the electrical outlet before cleaning.
  2. Remove Filter: Locate the air filter behind the front grille. Gently pull it out.
  3. Clean Filter: Wash the filter with warm, soapy water. Rinse thoroughly. For heavily soiled filters, a vacuum cleaner can be used to remove loose dust before washing.
  4. Dry Filter: Allow the filter to air dry completely before reinserting it. Do not use direct heat to dry.
  5. Reinstall Filter: Slide the dry filter back into its slot.

6.2 Cleaning the Unit Exterior

Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals, abrasives, or waxes, as these can damage the finish.

7. Troubleshooting

If your air conditioner is not operating correctly, refer to the following common issues and solutions before contacting service.

ProblemPossible CauseSolution
Unit does not turn on.No power; unit unplugged; circuit breaker tripped.Ensure unit is plugged in firmly. Check household circuit breaker/fuse.
Unit not cooling effectively.Dirty air filter; thermostat set too high; blocked airflow; room too large.Clean air filter. Lower thermostat setting. Ensure no obstructions to air vents. Verify room size is within unit's capacity.
Water dripping inside.Unit not tilted slightly outwards; drain blocked.Ensure proper slight outward tilt during installation for drainage. Check and clear any drain blockages.
Noisy operation.Loose installation; foreign object in fan; unit vibrating.Check installation for tightness. Inspect fan area for debris (unplug first). Ensure unit is level.

8. Specifications

AttributeValue
BrandGoldStar
Model NameR5050
Model Number2962-4145
Cooling Capacity5000 British Thermal Units (BTU)
Energy Efficiency Rating (EER)9.7
Voltage127 Volts
Power SourceCorded Electric
Product Dimensions (L x W x H)45.72 x 53.34 x 39.37 cm (18-9/16 x 12-9/32 x 14-9/16 inches)
Product Weight22.4 kg (49.4 lbs)
ColorWhite
Special FeaturesDust Filter, Rapid Cooling
Form FactorWindow

9. Warranty and Support

For specific warranty information and customer support, please refer to the documentation included with your purchase or visit the official GoldStar website. Keep your proof of purchase for warranty claims.

For technical assistance or service inquiries, please contact GoldStar customer service.

Related Documents - R5050

Preview Goldstar R1003 Room Air Conditioner Owner's Manual and Service Guide
Comprehensive owner's manual and service guide for the Goldstar R1003 room air conditioner, detailing specifications, features, disassembly procedures, installation steps, troubleshooting tips, and circuit diagrams. Includes information for models R1003A3 and R-8000AY3.
Preview GoldStar R5207 Room Air Conditioner Owner's Manual
Comprehensive owner's manual for the GoldStar R5207 room air conditioner, covering installation, operation, maintenance, troubleshooting, and warranty information. Includes safety precautions and electrical data.
Preview GOLDSTAR R5207 Air Conditioner Owner's Manual and Installation Guide
Comprehensive owner's manual and installation guide for the GOLDSTAR R5207 air conditioner, including setup instructions, parts list, electrical data, and troubleshooting tips.
Preview GOLDSTAR R-1802 Owner's Manual and Wiring Diagrams
Official owner's manual and schematic diagrams for GOLDSTAR R-1802, R1402, and R1801H air conditioners, including parts lists and wiring information. Provided by Appliance Factory Parts.
Preview Goldstar MAB745W MAB745B Microwave Oven Service and Owner's Manual
Comprehensive guide for the Goldstar MAB745W and MAB745B microwave ovens, covering installation, operation, safety precautions, specifications, troubleshooting, component testing, and exploded views for service and maintenance.
Preview Goldstar MS-701C Microwave Oven Owner's Manual and Cooking Guide
Comprehensive owner's manual and cooking guide for the Goldstar MS-701C microwave oven, covering operation, safety, installation, maintenance, and cooking tips. Includes detailed charts for heating, reheating, and fresh vegetables.