ArchiPro-LOGO

ArchiPro CB-PDT Programmable Plug-In Thermostat

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-PRODUCT

Product Usage Instructions

Overview

  • The Programmable Plug-In Thermostat is designed to provide a comfortable home environment while helping you save energy.
  • It can efficiently control various heating devices such as floor heating mats, wall heaters, air conditioners, ceiling heaters, oil heaters, convection heaters, and fan heaters.

Operation

  • Once installed and programmed, the thermostat will automatically regulate your heating device according to the preset schedule, ensuring optimal comfort and energy savings.

Product Instruction

  • This programmable electronic temperature controller will provide you with a comfortable home environment and will help you save energy.
  • The CB-PDT is ideal to operate floor heating mats, wall heaters, air conditioners, ceiling heaters, column (oil) heaters, bar (convection) heaters, or fan heaters

Technical Data

  • Voltage: AC200~240V, 50HZ
  • Load Current: 16A (electric heating)
  • Temperature Control Precision: ±1ºC
  • Temperature Setting Range: 5ºC – 35ºC
  • Self-Consumption Power: <0.3W
  • Temperature Sensor: NTC

Button Function Instruction

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-1

Display and Function Instructions

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-2 ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-3 ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-4

Quick Instruction of Operation Icon

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-5

Clock, timing, power on/off, setting

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-15

Clock Setting

  • Long press“ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-6” for 3 seconds, then move your finger to enter into settings screen, short press“ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-6” to choose “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-7” icon(ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-7flashing), press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-8” to enter into clock settings, it displays minute, hour, week, press ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-9” to adjust the value.
  • Press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-8” to confirm and switch to the next hour, week setting, which is the same as the minute setting. Press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-8” button to save all time settings and return to the previous screen.

Timing Power On/Off Setting

  • Long press“ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-6” for 3 seconds, then move your finger to enter into setting screen, short press“ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-6” to choose“ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-16”(ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-16flashing) to set time of timing power on; press ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-9to adjust the value. Press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-8” to choose “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-17” and set the timing power off.
  • Cancel timing power on/off: pressArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-10 ” to set as ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-1600:00, press ”ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-10” to set ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-17as 00:00.
  • It will quit automatically after the setting finishes in 5 seconds, or press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-8” button to return to the previous screen.

Periods Programmable Setting

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-11

The usage of temporary manual mode:
When thermostat is in period control, such as current time is 16:00, thermostat will set corresponding room temperature(factory setting is 15ºC) as per current period(factory setting afternoon going out period is 12:30-17:30), if current day you end work 1 hour earlier,(16:30 is 1 hour earlier than 17:30), you can press increase/decrease button temporarily to modify temperature to the temperature you wanted(such as 20ºC) , then the thermostat will keep the room temperature in 20ºC until next period, no any operation, thermostat will run the setting temperature (thermostat default 20ºC) automatically of afternoon entering room period (17:30-22:00) at 17:30.

Factory default periods programmable

ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-12

Advanced Setting (Suggest to be operated by Professional People only)

  • Under power on state, press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-13” for 3 seconds, then move your finger, enter into advanced settings, then press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-6” to choose one option, and press ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-9 to adjust the value.
  • To press “ArchiPro-CB-PDT-Programmable-Plug-In-Thermostat-FIG-6” to the next option. It will save settings and quit after 5 seconds.

FAQ

  • Q: How do I reset the thermostat to its default settings?
  • A: To reset the thermostat, locate the reset button (if available) or refer to the user manual for specific instructions on resetting to factory defaults.
  • Q: Can I use this thermostat with a cooling device?
  • A: No, this thermostat is designed specifically for controlling heating devices and may not be suitable for cooling equipment.