ACiQ B0DHFF2DKL

دليل مستخدم نظام مضخة حرارية مركزية عاكسة ACiQ سعة 2.5 طن وكفاءة طاقة 17 SEER2

Model: B0DHFF2DKL

1. المقدمة

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. معلومات السلامة

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • السلامة الكهربائية: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • التعامل مع المبردات: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • تثبيت: Installation must be performed by a licensed HVAC professional.
  • معدات الحماية الشخصية: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. الميزات الرئيسية

  • تكنولوجيا العاكس: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • كفاءة عالية: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • نطاق تشغيل واسع: Reliable performance from -13°F to 122°F.
  • التشغيل الهادئ: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • المكونات المتينة: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • المبردات الصديقة للبيئة: Utilizes R-454B refrigerant.
  • التثبيت المرن: Supports horizontal and vertical air handler installation.
  • عناصر التحكم الذكية: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. مكونات أكثرview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • وحدة معالجة الهواء الداخلية
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • واي فاي ترموستات
  • عرام حامي
  • محول شحن CPS
  • كم الجدار
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

الشكل 1: زيادةview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. الإعداد والتثبيت

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 فحوصات ما قبل التثبيت

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • تأكد من توفير مساحة كافية لكل من الوحدات الداخلية والخارجية، مما يسمح بتدفق الهواء المناسب وسهولة الوصول للصيانة.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

الشكل 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 وضع الوحدة الخارجية

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

الشكل 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. تعليمات التشغيل

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 أوضاع التشغيل الأساسية

  • وضع التبريد: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • وضع التدفئة: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • وضع المروحة: يقوم بتدوير الهواء دون تسخين أو تبريد.
  • نظام آلي: يتم التبديل تلقائيًا بين التدفئة والتبريد للحفاظ على درجة الحرارة المحددة.
ACiQ outdoor unit operating in extreme heat

الشكل 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

الشكل 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 أدوات التحكم الذكية

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

الشكل 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. الصيانة

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • استبدال فلتر الهواء: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • تنظيف الوحدة الخارجية: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • نظام الصرف الصحي: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • التفتيش المهني: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. استكشاف الأخطاء وإصلاحها

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • لا يوجد طاقة: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • عدم كفاية التدفئة/التبريد: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • ضوضاء غير عادية: تُعتبر الأصوات التشغيلية الطفيفة طبيعية. أما الأصوات العالية أو غير المعتادة فقد تشير إلى وجود مشكلة تتطلب فحصًا من قبل متخصص.
  • تسرب المياه: Check condensate drain line for blockages.

9. المواصفات

Dimensions of ACiQ indoor and outdoor units

الشكل 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

مخطط سعة التبريد لمضخة الحرارة ACiQ

الشكل 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

مخطط سعة التدفئة لمضخة الحرارة ACiQ

الشكل 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

ميزةالتفاصيل
سعة التبريد31,000 وحدة حرارية بريطانية/ساعة
سعة التدفئة30,000 BTU/hr (at 47°F)
تصنيف SEER218.8
تصنيف HSPF29.7
نوع المبردر-454ب
وحدة إمداد الطاقة الداخلية115/208/230V, 60Hz, 1Ph
مصدر طاقة الوحدة الخارجية208/230 فولت، 60 هرتز، أحادي الطور
أقصى طول للأنابيب164 قدم (50م)
Max Height Difference82 قدم (25م)
Indoor Unit Dimensions (W × D × H)21.02 بوصة × 21.02 بوصة × 49.02 بوصة
Outdoor Unit Dimensions (W × D × H)37.24 بوصة × 16.14 بوصة × 31.89 بوصة
الوزن الصافي للوحدة الداخلية128.97 رطل
الوزن الصافي للوحدة الخارجية164.02 رطل

10. الضمان والدعم

ACiQ offers a comprehensive warranty for this heat pump system:

  • ضمان قطع الغيار: سنتان
  • ضمان الضاغط: سنتان

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webموقع.

المستندات ذات الصلة - B0DHFF2DKL

قبلview أنظمة التدفئة القياسية أحادية المنطقة ACiQ 9K-24K: دليل التركيب والاستخدام
دليل تركيب وتشغيل أنظمة التكييف أحادية المنطقة ACiQ 9K-24K القياسية للتدفئة. يشرح هذا الدليل بالتفصيل تركيب وتشغيل وصيانة أنظمة التكييف ACiQ، بما في ذلك مواصفات الطراز ومعلومات عن غاز التبريد R454B.
قبلview دليل تركيب أنظمة العاكس المركزي ACiQ
دليل التثبيت الشامل لأنظمة تكييف الهواء المركزية ACiQ ومضخات الحرارة، يوضح بالتفصيل احتياطات السلامة، وأنابيب التبريد، وتركيب الوحدة الخارجية، والأسلاك، ومواصفات الطاقة، وإخلاء الهواء، وإجراءات التشغيل التجريبي.
قبلview وحدة معالجة الهواء المثبتة على الحائط ACiQ ومكثف الحرارة الشديدة أحادي المنطقة - التركيب ودليل المستخدم
يوفر هذا الدليل إرشادات تفصيلية حول التركيب والتشغيل والسلامة لمكيفات الهواء المثبتة على الحائط ACiQ ومكثفات المنطقة الواحدة ذات الحرارة الشديدة، والتي تغطي الطرازات من ACIQ-06W-HH-MD إلى ACIQ-24ZPL-HP230C.
قبلview دليل تركيب الوحدة الخارجية لأنظمة العاكس المركزي ACiQ
دليل التثبيت الشامل لوحدات ACiQ Central Inverter Systems الخارجية، والذي يغطي احتياطات السلامة، وأنابيب التبريد، والأسلاك، وتركيب الوحدة، وإجراءات الاختبار للطرز مثل ACiQ-18-AC، وACiQ-24-AC، وACiQ-18-EHPB، وغيرها.
قبلview نظام مضخة الحرارة القنوية ACiQ من الجيل التالي: دليل البدء السريع لتوصيلات الترموستات
يقدم هذا الدليل معلومات أساسية حول توصيل وتوصيل منظمات الحرارة بنظام مضخة الحرارة الأنبوبية ACiQ من الجيل التالي. ويوضح خيارات التوصيل الموصى بها والبديلة، بما في ذلك إعدادات مفتاح DIP وتكوينات كتلة الطرفية لمختلف أنواع منظمات الحرارة.
قبلview دليل المالك وتركيب وحدة معالجة الهواء والمكثف ACiQ Essentials Mini-Split
دليل شامل للتركيب والاستخدام لأنظمة ACiQ Essentials Mini-Split لمعالجة الهواء والتكثيف، يغطي احتياطات السلامة، وتحديد الأجزاء، وتشغيل جهاز التحكم عن بُعد، وإجراءات التركيب، والاختبارات، والصيانة، واستكشاف الأعطال وإصلاحها لمختلف الطرازات. يتضمن الدليل أيضًا معلومات هامة حول صيانة الأنظمة التي تستخدم غاز التبريد القابل للاشتعال R454B، مع التركيز على بروتوكولات السلامة والامتثال للوائح. صُمم هذا الدليل خصيصًا للفنيين المتخصصين والمستخدمين النهائيين لضمان التشغيل الآمن والفعال لأنظمة مضخات الحرارة ACiQ Mini-Split.