The Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge (Model 69ELF114TWG) is designed to reduce incoming water pressure to a safe and consistent level for residential and commercial plumbing systems. This unit features a compact design, lead-free bronze construction, and an integrated internal bypass mechanism. It includes a color-coded gauge for easy pressure monitoring and adjustment.

Apollo 3/4 inch Bronze Water Pressure Regulator with Gauge

Figure 1: Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge. This image shows the regulator with its integrated pressure gauge and yellow adjustment handle.

2. معلومات السلامة

3. محتويات العبوة

تأكد من وجود كافة المكونات قبل البدء في التثبيت:

4. التثبيت

This regulator features a double union PEX-A (cold expansion) barb design for simplified installation in PEX-A piping systems. Ensure the regulator is installed in the correct flow direction, indicated by an arrow on the body.

  1. تحضير موقع التثبيت: Turn off the main water supply. Drain the water lines to relieve pressure. Select a suitable location for the regulator, typically after the main shut-off valve and before any branch lines.
  2. Cut and Prepare PEX-A Piping: Cut the PEX-A pipe to the required length, ensuring clean, square cuts. Prepare the pipe ends for cold expansion connections according to PEX-A system manufacturer guidelines.
  3. قم بتوصيل المنظم:
    • Apply appropriate thread sealant (e.g., Teflon tape or pipe dope) to the male threads of the PEX-A fittings.
    • Thread the PEX-A fittings onto the double union ends of the regulator. Ensure the flow arrow on the regulator body points in the direction of water flow into the building.
    • Tighten the union nuts securely, but do not overtighten.
    • Perform cold expansion connections on the PEX-A pipe ends to the fittings according to PEX-A system manufacturer instructions.
  4. تثبيت مقياس الضغط: The pressure gauge is typically pre-installed. Ensure it is securely threaded into the designated port on the regulator body.
  5. Restore Water Supply and Check for Leaks: Slowly turn on the main water supply. Carefully inspect all connections for any signs of leaks. Tighten connections as necessary.
Apollo Water Pressure Regulator with PEX-A connections

الشكل 2: الجانب view of the Apollo Water Pressure Regulator, showing the double union PEX-A connections and the flow direction arrow. Note the "MAX INLET 400 PSI" marking.

5. تعليمات التشغيل

The regulator is factory-set at 50 psi and is adjustable from 15 psi to 75 psi. No special tools are required for adjustment.

  1. التحقق من الضغط الحالي: Observe the reading on the integrated pressure gauge. The gauge is color-coded to indicate pressure ranges (e.g., Low, Optimal, Excessive).
  2. ضبط الضغط:
    • ل يزيد pressure: Turn the yellow adjustment handle في اتجاه عقارب الساعة.
    • ل ينقص pressure: Turn the yellow adjustment handle عكس عقارب الساعه.
    • Make small adjustments and allow the system pressure to stabilize before re-checking the gauge.
  3. تأكيد الإعداد: Once the desired pressure is achieved (typically between 50-60 psi for most residential applications), confirm the reading on the gauge.
Apollo Water Pressure Regulator with gauge showing optimal pressure range

الشكل 3: الصورة عن قرب view of the Apollo Water Pressure Regulator, highlighting the pressure gauge with its color-coded optimal range and the yellow adjustment handle.

6. الصيانة

The Apollo Water Pressure Regulator is designed for minimal maintenance. Regular checks can help ensure optimal performance.

7. استكشاف الأخطاء وإصلاحها

مشكلةالسبب المحتملحل
No water flow or very low pressure downstreamRegulator set too low; Main water supply off; Regulator clogged.Increase pressure setting; Check main water valve; Inspect for debris (consult a plumber if necessary).
Pressure too high downstreamRegulator set too high; Regulator malfunction.Decrease pressure setting; If problem persists, regulator may need replacement.
Water hammer or fluctuating pressureRapid changes in water demand; Regulator bypass mechanism issue.Ensure proper air chambers are installed in the plumbing system; Consult a plumber for regulator inspection.
تسربات في التوصيلاتImproperly tightened connections; Insufficient thread sealant.Tighten connections; Reapply thread sealant if necessary (ensure water supply is off first).

8. المواصفات

9. الضمان والدعم

This Apollo Water Pressure Regulator comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact Apollo customer support.

For technical support or inquiries, please visit the official Apollo webالموقع أو الاتصال بقسم خدمة العملاء.

المستندات ذات الصلة - 69ELF114TWG

قبلview دليل مستخدم سكوتر Apollo Air الكهربائي - الإعداد والتشغيل والسلامة
دليل مستخدم شامل لسكوتر Apollo Air الكهربائي، يشمل معلومات الإعداد والتشغيل وإرشادات السلامة والصيانة والضمان. تعلّم كيف تستمتع بسكوتر Apollo Air بأمان.
قبلview دليل مستخدم سكوتر Apollo Go الكهربائي
دليل مستخدم شامل للدراجة البخارية الكهربائية Apollo Go، يغطي الإعداد والتشغيل والصيانة واستكشاف الأخطاء وإصلاحها وإرشادات السلامة.
قبلview Apollo POWER VS Series Turbine Instruction Manual - HVLP Spraying Guide
Comprehensive instruction manual for the Apollo POWER VS Series HVLP Turbine Spray Systems. Learn about setup, operation, maintenance, and best practices for achieving professional spray finishing results.
قبلview دليل مستخدم سكوتر Apollo Go الكهربائي
يقدم دليل المستخدم هذا تعليمات شاملة لسكوتر أبولو جو الكهربائي، تشمل فك العلبة، والتجميع، والتشغيل، والشحن، والصيانة، وإرشادات السلامة، واستكشاف الأخطاء وإصلاحها، ومعلومات الضمان. تعرّف على كيفية إعداد سكوتر أبولو جو الكهربائي، وقيادته، والعناية به.
قبلview دليل المستخدم وتجميع مدفأة Apollo 23G الكهربائية
دليل شامل لتجميع وتشغيل مدفأة Apollo 23G الكهربائية، بما في ذلك تعليمات السلامة وتحديد الأجزاء ونصائح استكشاف الأخطاء وإصلاحها للطراز HF190108/OLLIEFIR.
قبلview دليل تركيب لوحة اختيار الصوت Apollo SL15
يقدم هذا الدليل تعليمات مفصلة لتركيب وتشغيل لوحات اختيار الصوت/أنظمة الاتصال الداخلي من سلسلة Apollo SL15، بما في ذلك جهاز SL15M المزود بمؤشر إشارة داخلي. يغطي الدليل المعلومات العامة، وإجراءات التركيب، والتشغيل، والضمان.