1. انتهى المنتجview
This manual provides essential information for the safe and effective use of the Apollo Valve 13-213 Series Bronze Safety Relief Valve. This valve is designed for protecting small to medium low-pressure steam heating boilers by removing excess pressure from the system.
تتضمن الميزات الرئيسية ما يلي:
- Relief pressure preset of 15 psi for releasing excess pressure.
- 1-1/4" male NPT threaded inlet for connecting to a female NPT threaded connection.
- Cast bronze body and steel spring for corrosion resistance.
- Flat seat, PTFE-faced disc for positive seal.
- حاصلة على تصنيف السلامة ASME لغلايات التدفئة من القسم الرابع.

الشكل 1: الجبهة view of the Apollo Valve 13-213 Series Bronze Safety Relief Valve, showing the bronze body, NPT connections, and the pressure relief lever.
2. معلومات السلامة
Always adhere to local codes and regulations when installing and operating pressure relief devices. Improper installation or maintenance can lead to serious injury or property damage.
- Ensure the system is depressurized and cooled before attempting any installation, maintenance, or inspection.
- ارتدِ معدات الحماية الشخصية المناسبة، بما في ذلك نظارات السلامة والقفازات.
- لا تفعلamper with the factory-set pressure. Any alteration voids the warranty and can compromise safety.
- Ensure proper discharge piping is installed to safely vent steam away from personnel and equipment.
- Regularly inspect the valve for signs of wear, corrosion, or damage.
3. Components and Design
The Apollo Valve 13-213 Series is constructed with durable materials designed for steam applications. Key components include:
- جسم: Cast bronze for corrosion resistance and durability.
- مقعد: Flat seat design with a PTFE-faced disc for a positive seal, resistance to moisture, and high temperatures. This design also facilitates positive drainage of condensate.
- ربيع: Steel spring mechanism for reliable pressure relief.
- الاتصالات: 1-1/4" male NPT inlet and 1-1/2" female NPT outlet for secure pipe connections.

الشكل 2: الجانب view of the Apollo Valve 13-213 Series, highlighting the inlet and outlet connections and the robust bronze construction.
4. الإعداد والتثبيت
Proper installation is critical for the safe and effective operation of the relief valve. Consult a qualified professional if you are unsure about any step.
- إعداد النظام: Ensure the steam boiler system is completely shut down, depressurized, and cooled before beginning installation.
- اتصال مدخل: Thread the 1-1/4" male NPT inlet of the relief valve into the corresponding female NPT connection on the boiler. Use appropriate thread sealant (e.g., PTFE tape or pipe dope) suitable for steam applications. Tighten securely to prevent leaks, but do not overtighten.
- اتصال منفذ: Connect the 1-1/2" female NPT outlet of the relief valve to a discharge pipe. This pipe must be adequately sized and routed to safely vent steam to an open atmosphere or a designated safe discharge area, away from personnel and equipment. Ensure the discharge pipe has no obstructions, traps, or valves that could impede flow.
- توجيه: Install the valve in an upright position, ensuring the discharge path is clear and unobstructed.
- تسرب الاختيار: After installation, slowly bring the system up to operating pressure and carefully check all connections for leaks. Address any leaks immediately.
5. تعليمات التشغيل
The Apollo 13-213 Series Safety Relief Valve operates automatically to protect the boiler from overpressure conditions. It is designed to open when the system pressure reaches its factory-set relief pressure of 15 psi.
- عملية تلقائية: When the boiler pressure exceeds 15 psi, the valve will automatically open to discharge steam, reducing the pressure within the system.
- Reseating: Once the system pressure drops below the reseating pressure (typically slightly below the set pressure), the valve will automatically close, restoring the seal.
- Manual Test Lever: The valve is equipped with a manual test lever. It is recommended to periodically test the valve by lifting the lever to ensure it operates freely and discharges steam. This should be done carefully and only when the boiler is at a safe operating pressure, ensuring the discharge path is clear. Refer to boiler manufacturer guidelines for specific testing frequency.
6. الصيانة
Regular maintenance ensures the longevity and reliable operation of your safety relief valve. Always ensure the system is depressurized and cooled before performing any maintenance.
- التفتيش البصري: Periodically inspect the valve for any signs of external damage, corrosion, or leaks. Check the discharge piping for obstructions.
- الاختبار اليدوي: As mentioned in the operating instructions, perform periodic manual tests using the lever to ensure the valve opens and closes freely.
- تنظيف: Keep the exterior of the valve clean. Do not use harsh chemicals that could damage the bronze or other components.
- التفتيش المهني: It is recommended to have the valve inspected and serviced by a qualified professional at regular intervals, as per industry standards or local regulations.
7. استكشاف الأخطاء وإصلاحها
This section addresses common issues you might encounter with your safety relief valve.
| مشكلة | السبب المحتمل | حل |
|---|---|---|
| Valve Leaks Continuously | Debris on seat, damaged seat/disc, incorrect system pressure. | Manually cycle the valve to clear debris. If leaking persists, the valve may need replacement or professional servicing. Verify system pressure is below set point. |
| Valve Does Not Open | System pressure not reaching set point, valve stuck due to corrosion/deposits, incorrect valve for application. | Verify boiler pressure gauge accuracy. Attempt manual test. If stuck, valve may need replacement. Ensure valve specifications match system requirements. |
| Valve Opens Prematurely | System pressure fluctuating, valve spring fatigue, incorrect valve for application. | Monitor system pressure stability. If valve is old or frequently cycles, it may need replacement. Ensure valve specifications match system requirements. |
For issues not listed or if solutions do not resolve the problem, contact a qualified technician or the manufacturer.
8. المواصفات
Detailed technical specifications for the Apollo Valve 13-213 Series Bronze Safety Relief Valve:
- رقم الموديل: 13213ب15
- صمام نوع: صمام تخفيف الضغط
- مادة: Bronze (Body), Steel (Spring), PTFE (Seat Disc)
- اضبط الضغط: 15 psi (Pounds per Square Inch)
- نوع اتصال المدخل: 1-1/4" NPT Male Threaded
- نوع اتصال المنفذ: 1-1/2" FNPT Female Threaded
- درجة حرارة التشغيل القصوى: Up to 250 degrees F
- عدد الموانئ: 2
- امتثال: ASME Section IV - Low Pressure Steam Heating Boilers
- الشركة المصنعة: كونبراكو
- أول تاريخ متاح: 31 مايو 2012
- أبعاد الحزمة: 5.04 × 3.5 × 2.91 بوصة
- وزن السلعة: 2.05 رطل
9. معلومات الضمان
Specific warranty details for the Apollo Valve 13-213 Series are not provided within this manual. For comprehensive warranty information, please refer to the official documentation provided with your purchase or contact Apollo Valves directly through their official webالموقع أو قنوات خدمة العملاء.
10. الدعم والاتصال
If you require technical assistance, have questions regarding installation, operation, or maintenance, or need to report an issue, please contact the manufacturer:
- ماركة: APOLLO
- الشركة المصنعة: كونبراكو
- Webموقع: www.apollovalves.com (Please note: This is a general link to the brand's web(قد تختلف صفحات الدعم المحددة على الموقع.)
Always provide your product model number (13213B15) when seeking support.