AQUA-LOGO

AQUA Power Track Socket

AQUA-Power-Track-Socket-PRODUCT-IMAGE

PRODUCT PARAMETER

  • Track voltage: 250V~
  • Track power: 8000/(bidirectional terminal)
  • Frequency ratio: 50Hz
  • Track current: 324(direction terminal)
  • Security level: Ip20
  • Executive standard: GB/ T7251

Please read carefully before installation

Installer

All power rails must be installed by qualified electricians. The use of earth leakage circuit breaker (ELCB) requires that all power devices must be connected to the earth leakage circuit breaker to provide protection against overload, short circuit and earth leakage faults. Failure to comply with this requirement may cause danger.

Installation position

The installation position If all power tracks must complete hit corresponding national safety rules and regulations.

The installation surface

All power rails must be installed on a flat surface

Recommended installation clearance

For more information on the minimum clearance required for tightening. adapters, and accessories (away from the furor any fixed furniture), refer to figures 1 and 2 on the right.

Minimum mounting size

Fig. 1 The minimum clearance from the bottom is 25mm

AQUA-Power-Track-Socket-IMAGE-1

Figure 2 the minimum distance from the top is 20mm

AQUA-Power-Track-Socket-IMAGE-2

Track installation and positioning

  1. Identify the installation position and draw a parallel line according to the position (the track is not divided into left, right, up and down)AQUA-Power-Track-Socket-IMAGE-3
  2. According 1o the drawn line, align according to the upper edge, and make a fixed screw markAQUA-Power-Track-Socket-IMAGE-4
  3. Punch the hole position of expansion screw according to the markAQUA-Power-Track-Socket-IMAGE-5
  4. Tighten the screwsAQUA-Power-Track-Socket-IMAGE-6

Track outgoing mode I

  1. Connect the corresponding terminalAQUA-Power-Track-Socket-IMAGE-7
  2. wire outlet cover plateAQUA-Power-Track-Socket-IMAGE-8
  3. Connect the track with the reserved conductor It With clip , and the installation completedAQUA-Power-Track-Socket-IMAGE-9

Track outgoing mode II

  1. Connect the corresponding terminal and plug the wire along the track seatAQUA-Power-Track-Socket-IMAGE-10
  2. Cover the terminal coverAQUA-Power-Track-Socket-IMAGE-11
  3. Connect the track with the reserved conductor, align it with the clip, and the installation is completedAQUA-Power-Track-Socket-IMAGE-12

Track outgoing mode III

  1. Connect the corresponding terminal and plug the wire along the track slotAQUA-Power-Track-Socket-IMAGE-13
  2. Cover the terminal coverAQUA-Power-Track-Socket-IMAGE-14
  3. Align the snap and install itAQUA-Power-Track-Socket-IMAGE-15
  4. The apian wire led out is directly plugged Into the socket for power supplyAQUA-Power-Track-Socket-IMAGE-16

Customer retentionAQUA-Power-Track-Socket-IMAGE-17

Certificate

This product will be delivered after passing the inspectionAQUA-Power-Track-Socket-IMAGE-18

Warning

  • Keep away from fire source
  • Not suitable for outdoor use
  • Installation must be carried out by qualified electricians and installer