APOLLO Snow Melt Sensor Instruction Manual

APOLLO-logo

APOLLO Snow Melt Sensor

APOLLO-Snow-Melt-Sensor-PRODUCT

SAFETY PRECAUTIONS

  • Before installing or operating the sensor, read this manual carefully to ensure safe and correct use.
  • Installation and wiring must be performed only by qualified personnel, in accordance with applicable local electrical codes and regulations.
  • Always disconnect power before wiring, servicing, or removing the sensor to prevent electric shock or equipment damage.
  • Do not disassemble or modify the sensor, as it contains no user-serviceable parts. Unauthorized modifications may result in malfunction or void the warranty.
  • Install the sensor only in suitable outdoor locations, avoiding exposure to corrosive chemicals, excessive vibration, or conditions beyond the specified operating limits.
  • Ensure the system is powered down and secured before performing any maintenance or inspection.
  • Dispose of electrical components and packaging materials in accordance with local environmental and recycling regulations.

INTRODUCTION

The APOLLO Snow Melt Sensor is designed for reliable detection of snow or rain presence in outdoor environments. It operates using a frequency-domain reflection principle combined with high-frequency electronic measurement and an embedded microprocessor. This allows fast response, high sensitivity, and stable operation in harsh winter conditions. The sensor includes an integrated surface heating function to eliminate moisture accumulation and prevent false readings.

FEATURES

  • Capacitive detection technology for rain and snow presence
  • Aluminum housing
  • Normally Open (NO) relay contact available for HVAC control logic
  • Surface heating function
  • High sealing level, IP67
  • Strong resistance to electromagnetic interference
  • Multiple output signal options
  • Designed for long service life in outdoor installations

APPLICATIONS

This sensor is suitable for qualitative detection of rain or snow (presence / absence).

Typical applications include:

  • Hydronic snow-melt systems
  • Driveway and walkway heating systems
  • Roof and gutter ice prevention
  • Building automation systems (BMS)
  • Industrial and environmental monitoring

TECHNICAL SPECIFICATIONS

  • Measurement Rain / Snow presence
  • Operating temperature -30 °C to +70 °c
  • Operating humidity 0-99 % RH
  • Storage temperature -40 °C to +80 °c
  • Power supply 12-24 V DC
  • Stability time < 1 second
  • Response time < 1 second
  • Protection rating IP67
  • Housing material Aluminum
  • Auxiliary function Heating function

OUTPUT SIGNAL OPTIONS
The sensor supports multiple output configurations:

  • Relay output (Normally Open dry contact)
  • AC 220 V / 1 A
  • DC 24 V / 2 A
  • Voltage output: 0-2 V / 0-5 V / 0-10 V
  • Current output: 4-20 mA
  • RS485 (Modbus-RTU, default address 01)
  • N PN output
  • Combined outputs (Relay+ Current+ RS485)
  • SDl-12 protocol

Impedance requirement for the current signals:

Service voltage 9V 12V 20V 24V
Maximum Impedance <250 Ω <400 Ω <500 Ω <900 Ω

DIMENSIONS

APOLLO-Snow-Melt-Sensor- (1)

INSTALLATION

  • Install the sensor outdoors in an open area exposed to snowfall.
  • The sensor is supplied with a wall-mounting support, designed for secure installation on vertical surfaces.
  • The mounting support includes a 12-inch pipe (arm length) to position the sensor away from the wall and ensure proper exposure to snowfall.
  • The supplied support provides a fixed 15° inclination, ensuring the correct mounting angle to prevent snow accumulation on the sensing surface.
  • Avoid installation near sources of chemical corrosion.
  • Maintain adequate distance from high-voltage cables and strong heat sources.

APOLLO-Snow-Melt-Sensor- (2) APOLLO-Snow-Melt-Sensor- (3)

ELECTRICAL CONNECTIONS

The sensor may be connected to:

  • Snow-melt controllers
  • PLC or BMS digital inputs
  • Data acquisition modules

The wiring description is shown below: APOLLO-Snow-Melt-Sensor- (4)

DATA CONVERSION METHOD

OUTPUT SIGNAL NO RAIN (SNOW) THERE IS RAIN (SNOW)
Relay switch quantity (normally open) break actuation
0~2V DC 0.6V 1.6V
0 ~SV DC 1.5V 4V
0~l0V DC 3V 8V
4~20mA 6mA 16mA
RS485 0X000A 0X000B

RS485 signal (default address 01): Standard Modbus-RTU protocol,

  • Baud rate: 9600;
  • Check bit: no;
  • Data bit: 8;
  • Stop bit: 1

MODIFICATION ADDRESS
For example, change the sensor with address 1 to address to 2, the host slave.

The Original Address  

Function Code

High register Address The register Address is low The starting address is high The starting address is low  

CRC16 low

 

CRC16 high

0X0l 0X06 oxoo 0X30 oxoo 0X02 0X08 0X04

If the sensor is received correctly, the data is returned in the original route.
Note: If you forget the original address of the sensor, you can use the broadcast address 0 XFE instead. When using 0 XFE, the host can only connect to one slave, and the returned address is still the original address, which can be used as the method of address query.

QUERY DATA
Query the data of the sensor (address 01) (rain or snow), the host slave.

Address  

Function Code

Star register address is high Star register address is low The register length is high The register length is low  

CRC16 low

 

CRC16 high

0X0l 0X03 0X0l 0X84 0X0A

If the sensor receives correctly, return the following data to the slave host.

Address Function Code DL Register 0 data is high Register 0 datais low CRC16 low CRC16 high
0XOl 0X03 0X02 0X00                0X0A 0X38 0X43
No rain (snow): 0X000A Rain (snow): 0X000B

SET UP ACTIVE REPORTING
When it needs to be set to active reporting mode, the host slave.

APOLLO-Snow-Melt-Sensor- (7)

If the data returned to the host is the same as the sent data, the setting is successful.

  • When the air temperature is below the starting heating temperature (34°F/1℃), start the heating.
  • When the air temperature is above the stop heating temperature (77°F/25℃), the heating is stopped.
  • When the temperature is between 34°F/1℃ and 77°F/25℃, start heating when there is rain, and not heating when there is no rain. APOLLO-Snow-Melt-Sensor- (8)

SET OR QUERY THE START AND END TEMPERATURE OF AUTOMATIC HEATING

SET THE HEATING START TEMPERATURE
Hosting oneself from the machine APOLLO-Snow-Melt-Sensor- (9)

The data returned from the machine to the host is the same as the sent data, and the same description is set successfully.

SET THE HEATING STOP TEMPERATURE
Hosting oneself from the machine. APOLLO-Snow-Melt-Sensor- (10)

  • If the data returned to the host is the same as the sent data, the setting is successful.

MAINTENANCE

  • The APOLLO Snow Melt Sensor is designed for reliable, maintenance-free operation under normal environmental conditions. Periodic inspection is recommended to ensure optimal performance. Inspect the sensing surface regularly and remove any accumulated dirt, debris, or residue that may affect detection accuracy. Verify that all electrical connections are secure and that the cable insulation is intact.
  • Do not use abrasive materials, solvents, or high-pressure water when cleaning the sensor. If cleaning is required, use a soft cloth and clean water only. Any maintenance or inspection must be performed with the power supply disconnected. The sensor contains no user-serviceable internal components; disassembly or modification is not permitted.

COMMISSIONING PARAMETERS
All control parameters are adjustable at the controller level:

  • Outdoor temperature threshold
  • Slab temperature setpoint
  • Temperature differential
  • Maximum operating time

SAFETY & COMPLIANCE

  • The sensor must be installed by qualified personnel. All wiring shall comply with local electrical codes. Relay outputs must not exceed rated load limits.

SUPPORT
For technical assistance, contact:

APOLLO Heat Pump
info@mbtek.com
888-301-0737

Documents / Resources

PDF thumbnailSnow Melt Sensor
Instruction Manual · APOLLO, Apollo Hydronic Sensors, Snow Melt Sensor, sensor, Melt Sensor, Sensor
PDF thumbnailSnow Melt Sensor
User Manual · APOLLO, APOLLO HYDRONIC SENSORS, Apollo Snow Melt Sensor, Snow Melt Sensor, sensor
PDF thumbnailSnow Melt Sensor
User Manual · APOLLO HYDRONIC SENSORS, APOLLO Snow Melt Sensor, snow melt sensor, sensor

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.